厂家供应瑞光康泰脉搏波医用血压计RBP-9000c
企业档案
会员类型:旗舰版
已获得阿仪网信誉 等级评定
(0 -40)基础信誉积累,可浏览访问
(41-90)良好信誉积累,可接洽商谈
(91+ )优质信誉积累,可持续信赖
阿仪网旗舰版会员:1年
最后认证时间:
注册号: 【已认证】
法人代表: 【已认证】
参观次数:137368
手机网站:http://wap.app17.com/c174616/
旗舰版网址:http://ksdy.app17.com
详细内容
厂家供应瑞光康泰脉搏波医用血压计RBP-9000c
桂经理19117326863微xin同号
桂经理19117326863微xin同号
管理类别
第二类
型号规格
RBP-9000、RBP-9001、RBP-9002、RBP-9002P、RBP-9002L、RBP-9000c
结构及组成/主要组成成分
主要由主机、臂套、搁手板、电源线和操作指南板组成。
适用范围/预期用途
用于测量成人舒张压、收缩压和脉率,其数值供诊断参考。
一、工作原理 Working Principle
中文本设备采用专利脉搏波测量法(双气囊‑双传感器),模拟柯氏音听诊法原理;上游气囊用于阻断肱动脉血流,下游气囊与传感器采集动脉脉搏波信号;两个压力传感器同步采集袖带压力与脉搏波波形,通过专用算法解析脉搏波特征参数,计算得到收缩压、舒张压及脉率,完成血压测量,区别于普通示波法血压计。
EnglishThis device adopts patented Pulse‑Wave measurement method with dual‑airbag and dual‑sensor, simulating the principle of Korotkoff sound auscultation. The upper airbag occludes brachial artery blood flow; the lower airbag and sensors capture arterial pulse‑wave signals. Two pressure sensors simultaneously collect cuff pressure and pulse‑wave waveforms. Dedicated algorithms analyze pulse‑wave characteristic parameters to calculate systolic pressure, diastolic pressure and pulse rate for non‑invasive blood pressure measurement, different from conventional oscillometric sphygmomanometersPMC。
二、产品功能 Product Functions
中文
自动测量成人收缩压、舒张压、脉率;
5.7 英寸 LED 显示屏显示测量结果;
内置热敏打印机,测量完成自动打印报告;
真人语音提示、结果播报、故障 / 缺纸语音告警;
本地存储 100 组测量数据,支持记忆回看;
RS‑232、USB 双接口,可向 HIS 系统输出测量数据;
肘部位置传感辅助定位肱动脉;臂筒 ±10° 旋转调节;
超压自动急速排气保护功能。
English
Automatic non‑invasive measurement of adult systolic blood pressure, diastolic blood pressure and pulse rate.
5.7‑inch LED display for measurement results.
Built‑in thermal printer for automatic report printout after measurement.
Human‑voice prompt, result read‑out, voice alarm for fault / paper‑out status.
Local storage for up to 100 measurement sets; memory recall supported.
Dual communication ports: RS‑232 and USB for data export to hospital HIS system.
Elbow position sensor assists brachial artery alignment; arm tunnel adjustable within ±10° rotation.
Automatic rapid exhaust over‑pressure protectionPMC。
三、产品特点 Product Features
中文
双气囊双传感脉搏波专利技术,测量精度压力 ±2mmHg;
臂筒一体式设计,左右上臂均可测量;适配臂周 17‑42cm;
智能肘部定位传感器,减少人为放置误差;臂筒角度可调提升舒适度;
接触部位抗菌可拆洗臂套,便于院感管控;
全自动加压、线性减压,无需人工操作袖带;
数据存储、打印、HIS 对接三位一体,适合门诊、体检机构;
I 类 B 型医用电气安全,整机约 8kg,设计使用期限 5 年。
English
Patented dual‑airbag dual‑sensor Pulse‑Wave technology; pressure accuracy ±2 mmHg.
Integrated arm‑tunnel design; supports right / left upper‑arm measurement; fits arm circumference 17‑42 cm.
Intelligent elbow‑positioning sensor reduces manual placement error; rotatable arm tunnel improves comfort.
Removable, washable and antimicrobial contact cuff cover for hospital infection control.
Fully‑automatic inflation and linear deflation; no manual cuff wrapping required.
Integrated data storage, printout and HIS interface, suitable for outpatient and physical‑examination settings.
Class I, Type B applied part for medical electrical safety; unit weight approx. 8 kg; service life 5 yearsRaycome。
四、技术参数 Technical Specifications
表格
| 中文 | English |
|---|---|
| 型号:RBP‑9000c | Model: RBP‑9000c |
| 测量方法:脉搏波法 | Measurement Method: Pulse‑Wave Method |
| 压力测量范围:0‑300 mmHg(0‑40 kPa) | Pressure Range: 0‑300 mmHg (0‑40 kPa) |
| 脉率测量范围:40‑180 次 / 分 | Pulse Rate Range: 40‑180 beats/min |
| 压力准确度:±2 mmHg(±0.267 kPa) | Pressure Accuracy: ±2 mmHg (±0.267 kPa) |
| 脉率准确度:±2% | Pulse Rate Accuracy: ±2% |
| 适用臂周:17 cm‑42 cm | Applicable Arm Circumference: 17 cm‑42 cm |
| 存储容量:100 组数据 | Memory Capacity: 100 datasets |
| 显示屏:5.7 寸段码 LED | Display: 5.7‑inch segment LED |
| 打印机:内置热敏打印机 | Printer: Built‑in thermal printer |
| 通信接口:RS‑232、USB | Communication: RS‑232, USB |
| 电源:AC 100‑240V,50‑60Hz,0.8‑1.6A | Power Supply: AC 100‑240V, 50‑60Hz, 0.8‑1.6A |
| 使用环境温度:5℃~40℃ | Operating Temperature: 5℃~40℃ |
| 使用湿度:15% RH‑80% RH | Operating Humidity: 15%RH‑80%RH |
| 运行大气压:80‑106 kPa | Operating Atmospheric Pressure: 80‑106 kPa |
| 外形尺寸:471.5 mm×402.0 mm×309.0 mm | Dimensions: 471.5 mm×402.0 mm×309.0 mm |
| 主机重量:约 8.0 kg | Unit Weight: approx. 8.0 kg |
| 电击保护分类:I 类、B 型应用部分 | Electrical Safety: Class I, Type B applied part |
| 设计使用期限:5 年 | Design Service Life: 5 yearsraycome.ne... |

五、使用方法 Operating Instructions
中文
将设备接通交流电源,开机完成自检;
受试者取坐姿,身体放松,手臂伸入臂筒,肘部对齐肘部定位传感器;可微调臂筒角度至舒适姿态;手臂与心脏保持同一水平;
确认手臂完全置于臂筒内部,按下【启动 / 停止】按键;
设备自动加压、采集脉搏波信号、自动减压;测量过程中受试者保持安静、不说话、肢体不动;
测量完成,屏幕显示收缩压、舒张压、脉率;语音播报结果,可选自动打印;
读取或打印数据;可按记忆键调取历史记录;测量完毕受试者取出手臂,关机;
若出现异常可按停止键终止测量。
English
Connect AC power and power‑on for self‑test.
Subject sits relaxed, insert upper arm into arm tunnel, align elbow with elbow‑position sensor. Adjust arm‑tunnel angle for comfort. Keep arm at heart‑level height.
Ensure arm is fully inside tunnel, press 【Start/Stop】 key.
Device performs automatic inflation, pulse‑wave acquisition and automatic deflation. Subject shall remain still, silent during measurement.
Upon completion, systolic / diastolic pressure and pulse rate are displayed on screen; voice read‑out and optional auto‑print are performed.
Read or print results. Press memory key to review historical records. Subject withdraw arm after test, power off unit.
Press Stop key to abort measurement in case of abnormality.

六、适应症(预期用途)Indications / Intended Use
中文适用于成人测量上臂收缩压、舒张压与脉率,测量数值仅供临床诊断参考,不作为单一确诊依据。
EnglishIntended for non‑invasive measurement of upper‑arm systolic blood pressure, diastolic blood pressure and pulse rate in adults. Measured values are for clinical reference only and shall not serve as sole diagnostic evidence.
七、禁忌症 Contra‑indications
中文
禁止用于婴幼儿、儿童;仅用于成人;
上臂有外伤、烧伤、术后创面、大面积皮肤破损、感染、血管造瘘侧肢体,禁止在该上臂测量;
重度躁动、无法保持安静配合的受试者不适合本设备测量;
不可用于有创血压替代,不能用于麻醉中危重患者连续监护;
不要在同一上臂同时连接其他监护设备。
English
Not for infants or children; intended for adults only.
Do NOT measure on upper arm with trauma, burn, surgical wound, extensive skin lesion, infection or vascular fistula.
Not suitable for severely agitated subjects who cannot stay still during measurement.
Cannot replace invasive blood‑pressure monitoring; not designed for continuous critical‑care monitoring under anesthesia.
Do not attach other monitoring devices to the same upper arm simultaneously.

八、注意事项 Precautions
中文
测量前受试者静坐休息至少 5 分钟;测量前 30 分钟禁止吸烟、喝咖啡、浓茶、剧烈运动;
测量时身体挺直、不要说话、不要移动手臂、不要翘二郎腿;手臂务必与心脏同一高度;
臂套应保持清洁,可拆洗,需定期检查有无老化破损;
设备为交流供电,禁止在潮湿环境、浴室使用;避免液体泼洒主机;
若多次测量,两次测量间隔建议≥3 分钟;
设备仅作筛查参考,血压异常请遵医嘱进一步诊疗;不可仅依靠本设备结果自行调药;
请勿自行拆解主机;维修校准由厂家或授权人员执行;
出现频繁超压报错、排气异常应停止使用,联系售后;
电磁环境会影响测量,远离大功率射频设备。
English
Subject shall rest seated for at least 5 min before measurement. No smoking, coffee, strong tea or strenuous exercise within 30 min prior to test.
Sit upright; avoid talking, arm movement or leg‑crossing during measurement. Arm shall be maintained at heart‑level.
Cuff cover shall be kept clean; removable for washing. Regularly inspect for aging or damage.
Unit is AC‑powered. Do not operate in humid or bathroom environments. Prevent liquid spillage onto main unit.
For repeated measurements, allow ≥3 min interval between tests.
Device provides screening reference only. Seek further medical consultation for abnormal readings. Do NOT adjust medication solely based on this device.
Do not disassemble main unit. Maintenance and calibration shall be performed by manufacturer or authorized personnel.
Stop operation and contact service if repeated over‑pressure alarms or abnormal exhaust occur.
Electromagnetic interference may affect measurement. Keep away from high‑power radio‑frequency equipment.
九、存储 / 运输条件 Storage & Transport Conditions
中文贮存运输温度:‑20℃~+55℃; 最大相对湿度:≤93% RH(无凝露); 贮存运输大气压力:50 kPa~106 kPa; 存放环境避免雨淋、暴晒、粉尘、腐蚀性气体。
EnglishStorage / Transport Temperature: ‑20℃~+55℃; Max. Relative Humidity: ≤93%RH (non‑condensing); Storage / Transport Atmospheric Pressure: 50 kPa~106 kPa; Avoid rain, direct sunlight, dust and corrosive gas during storage and transport.

十、说明书核心摘要 Core IFU Summary
中文RBP‑9000c 是 Ⅱ 类医用臂筒式脉搏波血压计,采用双气囊双传感器专利脉搏波技术,用于成人上臂血压与脉率筛查;整机自动加压减压,内置打印、语音播报、数据存储及 HIS 对接接口;使用时受试者坐姿,手臂入筒,肘部定位,保持静止完成测量;仅用于成人,不可用于儿童;上臂伤口、造瘘肢体禁止测量;需遵守休息时间、手臂高度要求;环境温湿度、电磁条件需符合规格;设备读数仅供医生参考,不替代临床诊断;定期维护,不可私自拆机,按规定条件存储运输,设计使用寿命 5 年raycome.ne...。
EnglishRBP‑9000c is Class II medical arm‑tunnel non‑invasive sphygmomanometer adopting patented dual‑airbag dual‑sensor Pulse‑Wave technology for upper‑arm blood‑pressure and pulse‑rate screening in adults. It features automatic inflation/deflation, built‑in printing, voice prompt, data memory and HIS‑system interface. Subject shall sit, insert arm into tunnel, align elbow and remain motionless for measurement. For adults only; contra‑indicated for children. Avoid measurement on arms with wound or vascular fistula. Follow pre‑test rest requirement and heart‑level arm placement. Operate within specified temperature, humidity and electromagnetic environment. Readings are for physician reference and do not replace clinical diagnosis. Periodic maintenance required. Unauthorized disassembly prohibited. Store and transport as specified. Design service life: 5 yearsPMC。
免责提示:以上产品详情仅供参考,临床操作请以原厂纸质说明书为准。上海康世达医疗器械有限公司不生产医疗产品,所有产品均来自产品的生产厂家,代理商,经销商,如有侵权请联系我们,会尽快处理!The above product details are for reference only. All clinical operations shall be carried out in strict accordance with the original paper instructions for use issued by the manufacturer.
Shanghai Kangshida Medical Devices Co., Ltd. does not manufacture medical devices. All products are sourced from respective manufacturers, authorized agents and distributors.
Please contact us promptly in case of any infringement, and we will resolve the matter as soon as possible.
热门标签:厂家供应瑞光康泰脉搏波医用血压计RBP-9000c,瑞光康泰脉搏波医用血压计,血压计RBP-9000c