提供者:徐州三原自动化技术有限公司 发布时间:2019/8/11 20:48:50 阅读次数:437次 进入该公司店铺
The outline of debugging
一. The install preparation before test调试前准备
二. Adjust the contents调试内容
ZERO umulative total零点累计值: 皮带空荷运行整数圈后,零点指示器的累计示值应不大于这段时间内,在特/大流量下所应累计负荷的百分比:0.05%
Empty in leather belt movement integral an empress, the zero orders the total amount of the indicator shows value should not very in this time inside, a percentage for should total amount carrying under the biggest discharge:0.05%
Measure time测量时间min | ZERO umulative total零点累计示值kg | Error允差kg | Conclusion结论 |
在皮带秤上放置链码,皮带运转整数圈,记录累计示值,照此共做5次,五次检测结果中的特/大值与特/小值之差,与五次称量累计示值平均值之比,应符合0.25%的要求。
belt weighers ascend place Chain code, leather belt revolve integral turn, record total amount showed value, shone on this totally did 5 times, five times examine result of the biggest value is worth and bad with least, with measure five times the total amount shows the value average worth ratio, at the request of match 0.25%.
Test No. | 1 | 2 | 3 | 5 | 6 |
Total累计值(kg) | |||||
极差Errormax(kg) | 允差Errorallowable | 结论Conclusion |
三、EXPLAIN说明
调试结束后,皮带秤可投入正常运行,若运行过程中,对所过物料的重量有所怀疑,则可用高于精度0.25%的其它秤(比如斗秤、汽车衡等)对皮带秤所称的物料进行核准,若超差,则可用链码重新对皮带秤进行标定。
Adjust to try the be over empress, belt weighers can throw in the normal movement, if circulate the process inside, having the doubt to a weight for over material, then canning use higher than uracy 0.125% other the weighers ( for example the weighers of bicker , car weighers etc.) proceeds the sanction to the belt weighers a material for calling, if super bad, then can use the Chain code to proceed to the belt weighers.
徐州三原自动化技术有限公司
常年低价提供原厂备件MT2101,SYDL2105,SY3011,XR2105,SY2105,2001,ET2000等称重控制器。60-12X,PLR-12R测速传感器,STC,SHBXR,HBB,HBM等称重传感器。电子皮带秤,定量给料机,失重秤……
现货供应,无法提供详细型号可根据现场推荐型号,对于现场无法更换的客户可以无偿提供技术支持或者现场技术服务。
① 凡本网注明"来源:阿仪网"的所有作品,版权均属于阿仪网,未经本网授权不得转载、摘编或利 用其它方式使用。已获本网授 权的作品,应在授权范围内使用,并注明"来源:阿仪网"。违者本网将追究相关法律责任。
② 本信息由注册会员:徐州三原自动化技术有限公司发布并且负责版权等法律责任。
版权声明