欢迎来到 阿仪网

免费注册

首页|产品|求购|资讯|专题|找厂商|打听|品牌|资料|技术文献|展会|新品|促销|招标|优质仪器
广告

植物(Plant)有机磷水解酶(MPH) ELISA检测试剂盒#2022年已更新《天气/台风》

提供者:上海舒话生物科技有限公司   发布时间:2022/8/12 14:34:44  阅读次数:527次  进入该公司店铺

商家名片
沈**
请说明是阿仪网看到我的,谢谢!
  • 公司:上海舒话生物科技有限公司
  • 电话:18******304
  • 手机:18******304
  • 微信:***
  • 交换名片后展示联系方式

交换名片

试剂盒性能

1. 准确性:标准品线性回归与预期浓度相关系数R值,大于等于0.9900。

2. 灵敏度:检测浓度小于1.0 IU/mL。

3. 特异性:不与其它可溶性结构类似物交叉反应。

4. 重复性:板内、板间变异系数均小于15%。

5. 贮藏:2-8℃,避光防潮保存。

6. 有效期:6个月

免责声明

1. 试剂盒仅供研究使用,不得用于临床实验或人体实验,否则所产生的一切后果,由实验者承担,本公司概不负责。

2. 严格按照说明书操作,实验者违反说明书操作,后果由实验者承担。

FOR RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

PlantMPHELISA Kit instruction

Intended use

This MPH ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures.The S Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of MPH in the sample, this MPH ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus MPH concentration. The concentration of MPH in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Samplecollection and storages

1. Can’t detect the samples which containNaN3, because NaN3 inhibits HRP activity of the horseradish peroxidase.

2. Extract as soon as possible after Specimen collection, Extracted according to the relevant literature.

Cell culture supernates and plant exact fluids - Remove particulates by centrifugation andassay immediately or aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw.

Materials required but not supplied

1. Standard microplate reader(450nm)

2. Precision pipettes and Disposable pipette tips.

3. 37 ℃ incubator

Precautions

1. Donot substitutereagentsfromone kit to another.Standard, conjugateandmicroplates are matchedfor optimal performance. Useonly thereagentssuppliedby manufacturer.

2. Donot removemicroplatefrom the storage baguntilneeded. Unusedstripsshouldbe stored at2-8°Cin their pouchwith the desiccantprovided.

3. Mix all reagents before using.

Remove allkit reagentsfrom refrigerator and allow them to reachroom temperature( 20-25°C)

Materials supplied

Name

96determinations

48determinations

Microelisa stripplate

12*8strips

12*4strips

Standard

0.3ml*6tubes

0.3ml*6tubes

Sample Diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

S Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note: Standard (S0→ S5) concentration was followed by:0,30,60,120,240,480 IU/mL

Reagent preparation

20×wash solution:Dilute with Distilled or deionized water1:20.

Assay procedure

1. Prepare allreagentsbeforestartingassayprocedure. ItisrecommendedthatallStandardsand Samplesbe addedin duplicateto the MicroelisaStripplate.

2. Add standard: Set Standard wells, testing sample wells. Add standard 50μl to standard well.

3. Add Sample: Add testing sample10μl then add Sample Diluent 40μl to testing sample well; Blank welldoesn’t add anyting.

4. Add100μlofHRP-conjugate reagentto each well,cover with an adhesive stripandincubatefor60 minutes at37°C.

5. Aspirate each well and wash, repeating the process four times for a total of five washes.Wash by filling each well with Wash Solution (400μl) using a squirt bottle, manifolddispenseror autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Solution by aspirating ordecanting. Invert the plate and blot it against clean paper towels.

6. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

7. Add 50μl S Solution to each well. The color in the wells should change from blue toyellow. If the color in the wells is green or the color change does not

appear uniform,gently tap the plate to ensure thorough mixing.

8. ReadtheOpticalDensity(O.D.)at450nmusinga microtiterplatereaderwithin15minutes.

Calculation of results

1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.

2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.

3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.

4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

5. The sensitivity by this assay is1.0 IU/mL

6. Standard curve

Storage: 2-8℃.

validity:six months.

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS!PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

优质商品

X射线荧光光谱仪
X射线荧光光谱仪

版权声明

① 凡本网注明"来源:阿仪网"的所有作品,版权均属于阿仪网,未经本网授权不得转载、摘编或利 用其它方式使用。已获本网授 权的作品,应在授权范围内使用,并注明"来源:阿仪网"。违者本网将追究相关法律责任。

② 本信息由注册会员:上海舒话生物科技有限公司发布并且负责版权等法律责任。

旗下频道

色谱仪光谱仪反应釜试验箱试验机搅拌器培养箱离心机水分测定气体检测量热仪石油仪器纯水器比表面仪温度记录泵流量计万用表显微镜粒度仪测厚仪硬度计酸度计元素分析生物试剂电线电缆天平衡器传感器食品检测压力仪表电化学测厚仪阀门仪表电力仪表干燥设备药物检测