110V转正负15V电源模块,DC-DC模块电源,150W电源

110V转正负15V电源模块,DC-DC模块电源,150W电源

北京诚远信达电子科技有限公司

专业从事AC-DC,DC-DC开关电源及模块电源的研究开发及制造,是国内较早从事电源研发生产的厂家之一,公司为中国电源协会成员单位。公司产品广泛应用于工控、通讯、电力、医疗、科研、军工、安防、LED、仪器仪表、航天航空、船舶机械等领域。

联系人:宋爱民 先生

电话:18612703179

QQ :    953617934

该公司产品分类: 定制电源 开板电源 消防电源 超薄电源 模块电源 开关电源

MDA-MB-157细胞

 MDA-MB-157细胞  细胞信息(说明书,鉴定书),售后情况,细胞活动请联系 :
在线QQ:2215398442   邮箱:tongpaibio@126.com  提供耐药细胞株,细胞染色等技术服务。

流式细胞仪测定。(4×105/孔,6孔板,2mL/孔) 若第二天流式测量,可加5—10mL70%乙醇,在4℃固定8h以上。 

Caco-2细胞 人结直肠腺癌细胞  http://www.afzhan.com/st133337/Product_3325168.html

CaSki细胞 人宫颈癌细胞 CaSki细胞传代 http://www.afzhan.com/st133337/Product_4632941.html

制备细胞凋亡单染管: 活细胞 

一半活细胞+一半死细胞(高温灭活-水浴90℃)+FITC(染色活Cell) 

一半活细胞+一半死细胞+PI(PI-碘化丙啶染色核酸,但不能穿透细胞膜即染色死Cell) 

Caco-1细胞人结直肠细胞/Caco-2细胞传代  http://www.afzhan.com/st133337/Product_4632937.html

Caco-2细胞直肠腺癌细胞 Caco-2细胞价格  http://www.afzhan.com/st133337/Product_4592202.html

一半活细胞+一半死细胞+FITC(碱性环境与抗体蛋白反应,主要是与赖氨酸的氨基与荧光素的硫碳胺键结合,形成FITC-蛋白质结合)+PI PBS的配制:(1000mL)  NaCl 8.0 g 、KCl 0.2 g、 KH2PO4 0.2 g 、Na2HPO4.12H2O 2.9 g 加超纯水至1000mL高压蒸汽灭菌,4℃储存,备用。 细胞器具清洗:  瓶、管等+洁消精(过夜12 h),自来水冲洗25遍,蒸馏水

BS-C-1细胞洲绿猴肾细胞 BS-C-1细胞价格  http://www.afzhan.com/st133337/Product_4592195.html

BS-C-1细胞 非洲绿猴肾细胞  http://www.afzhan.com/st133337/Product_3324740.html

冲1-2遍,蒸馏水泡过夜12 h,烘干,高压蒸汽灭菌(约2 h),再烘干,至少2-3天,方可用。 

MTT溶液的配制:MTT浓度为5 mg/mL,溶于PBS或无酚红的培养基中,用0.22 um滤膜过滤以除去溶液里的细菌,放4℃避光保存即可。 

人黑色素瘤细胞 A875细胞 / A875细胞价格 http://www.afzhan.com/st133337/Product_4632928.html

A875细胞 人黑色素瘤细胞 A875细胞培养 http://www.afzhan.com/st133337/Product_4592191.html

A875细胞 人黑色素瘤细胞 http://www.afzhan.com/st133337/Product_3324708.html

注:

在酶标仪检测结果时,为保证实验结果的线性,MTT吸光度最好在0-0.7范围; 

人乳腺导管癌细胞ZR751细胞/ZR751细胞价格 http://www.afzhan.com/st133337/Product_4592182.html

ZR751细胞 人乳腺导管癌细胞  http://www.afzhan.com/st133337/Product_3324675.html

人乳腺导管癌细胞 ZR-75-1细胞 http://www.afzhan.com/st133337/Product_4394341.html

MTT一般现用现配,过滤后4℃,避光保存2周有效,或保存在-20℃长期保存;避免反复冻融,最好小剂量分装,用避光袋、锡箔纸包裹;一般把MTT粉分装在EP管,再现用现配,当MTT变为灰绿色时绝不能再用; MTT致癌,用时最好带透明薄膜手套。

该公司产品分类: 细胞

154N型低压压力传感器

电气连接:
导线、焊盘、导线带、导柱
类型:
表压,绝压 316SS不锈钢隔离膜片
特点:
压力1PSI,O型密封圈或螺纹连接
供电电源:
1.5mA
输出:
0~100mV
精确度
±0.25%非线性
工作温度范围
-40℃~125℃ (补偿:-20~85℃)
量程:
0~1,5(psi)
典型应用:
压力变送器,医疗仪器,试验设备,真空装置

美国奥豪斯 CP213/CP313/CP413/CP153 0.001g 电子天平

【先行者通用型天平 CP系列 0.001g的参数说明】
 
独特的应用特点: 1.中文操作面板-使操作更加简单便捷 2.前置式水平调节泡-方便操作者对天平进行水平调节 3.多组合式风罩-5片玻璃无须任何工具就可轻松拆卸,充分满足您不同的称量需求 4.优化的微小加样称量-采用的数字处理技术,在保持天平读数稳定性的同时,大大提高对微量加量的响应速度 5.动态温度补偿功能-时时修正环境温度变化对称量结果的影响
独特的应用功能: 1.多种称量单位-毫克、克、千克、盎司、磅、克拉等及可自定义单位 2.环境滤波优化设置-根据用户工作现场的环境特点,可对天平进行高、中、低滤波优化设置,从而使称量结果更快速、更稳定 3.自动清零设置-环境的变化可能引起显示的漂移,自动清零设置可以即使环境有微小的变化,天平仍然保持从0克开始称量 4.经典应用模式-计件称量和百分比称量 5.内置下挂式秤钩-满足用户进行下挂式密度测定和其他特殊称量要求,如大体积样品的称量等 6.标配RS232通讯接口-方便连接打印机、电脑和其他设备 7.选配第二显示器-可同步显示天平上的称量值,方便数据的读取
经典应用模式: 1.计件称量-此应用模式可计算单一重量物品的数量,天平通过已记录样品的单重值,称量多个样品时,天平会自动显示称量样品的个数,可用于库存控制、零件打包、验收、分配和计票等工作。先行者通用型天平不仅具有标准计数功能还具有平均单件重量化功能。 2.百分比称量-广泛用于溶剂溶液配比的称量方法。在该模式下,先在秤盘上放上样品作为参考重量,参考重量将显示为100%,而后放上的其他载荷将以与参考重量比较后的百分比方式显示。
型号 
量程
可读性
市场报价
CP153C  内校
151g
0.001g
7000.00
CP223C  内校
220g
0.001g
7600.00
CP323C  内校
320g
0.001g
8200.00
CP423C  内校
420g
0.001g
8800.00
CP153   外校
151g
0.001g
4300.00
CP213   外校
210g
0.001g
4700.00
CP313   外校
310g
0.001g
5300.00
CP413   外校
410g
0.001g
6100.00

温州瑞昕仪器有限公司

温州瑞昕仪器有限公司是从事工业用检测仪器、理化分析仪器、计量仪器产品的销售、服务、维修一体的公司。欢迎您的咨询订购,联系方式:

公司电话:0 5 7 7-6 6 8 8 6 0 1 7

传真:0 5 7 7-6 6 8 8 6 0 1 9

邮箱:rxin17@163.com

网址:http://www.rxin17.com/

联系人:

陈进碗   手机:1 3 7 5 8 7 6 8 8 1 3 QQ124677072

该公司产品分类: 石油类分析实验室常用仪器 专用气相色谱 反渗透去离子纯水机 超纯水机 实验室纯水系统 普利赛斯 梅特勒 美国奥豪斯 上海精科 上海越平 日本AND/A&D 电子天平 液相色谱柱 气相色谱柱 安捷伦液相 岛津液相 伍丰液相 液相色谱仪 注射器 岛津 耗材和配件

JC-101A型COD恒温15孔消解仪

JC-101A型COD恒温15孔消解仪
一、JC-101A型COD恒温15孔消解仪产品简介:►JC-101A型COD恒温加热器(COD消解仪)是经典方法分析污水中一种采用空气冷凝代替水冷凝测定化学耗氧量的加热回流装置,它采用新型温控器,升温速度快,温度恒定均匀,操作方便,是一种实验手段仪器化新产产品。经国家环保局环境监测仪器质量监督检验中心测试表明,结果符合国际标准方法ISO06066-86的要求。采用数字化设定、显示加热温度,自动控制加热温度,可设定加热时间。升温速度快,温度恒定均匀,耗电小,操作简单,性能稳定可靠,广泛用于环保、医疗、卫生、食品、自来水、造纸、污水处理、印染、石化、冶金、院校等行业的水质检测。►至2014年9月18日起聚创JC-101A型产品全面升级,加热孔数升级为15孔。在此日期之前订购该型号产品的客户再次订货需提前与服务人员确认,以免影响您的正常使用。二、JC-101A型COD恒温15孔消解仪技术特点:1、国内首家推出具有时间控制型恒温加热器;时间可任意设定。2、国内首家自动进行计算加热回流时间,无需人工进行计时,加热回流时间2小时到达完毕后,仪器自动关机。3、温漂小、节能、节水、耗电小,升温速度快。4、加热板底部采用特殊材质和加工工艺制作,每个加热孔部位恒温均匀。5、最新工艺表面防腐处理,增加仪器的使用年限。6、高精度铝锭恒温加热,保证样品的实验精准度,是环保、安监、实验室首选仪器。7、新增消解结束报警提示功能。8、免校准温度,简化使用步骤。三、JC-101A型COD恒温15孔消解仪技术指标:1、温度范围:32°C ~ 399°C(可调)2、恒温精度:±2°C3、升温时间:(180°C)<20min4、消解控制:0-99小时;0-99分钟;0-99秒分段可调5、最大功耗:1.2KW6、电        源:AC220V  50Hz7、加热样品数:15个可定做孔数。                               可OEM贴牌或提供中性产品。8、电源电压:AC220V±10%,50Hz9、外形尺寸:40cm*29cm*10cm(长*宽*高)青岛聚创环保公司为您提供全面的技术支持和完善的售后服务!详情咨询:!
 
 
该公司产品分类: 酸化吹气仪 COD测定仪 COD消解器 红外测油仪 显微镜 干燥箱 电子天平

大鼠生长分化因子15,GDF15,ELISA,试剂盒

大鼠生长分化因子15(GDF15)elisa试剂盒

 

 

本试剂盒只能用于科学研究,不得用于医学诊断

大鼠生长分化因子15GDF15ELISA检测试剂盒

使用说明书

检测原理

剂盒采用双抗体一步夹心法酶联免疫吸附试验(ELISA)。往预先包被大鼠生长分化因子15GDF15)捕获抗体的包被微孔中,依次加入标本、标准品、HRP标记的检测抗体,经过温育并洗涤。用底物TMB显色,TMB在过氧化物酶的催化下转化成蓝色,并在酸的作用下转化成最终的黄色。颜色的深浅和样品中的大鼠生长分化因子15GDF15)呈正相关。用酶标仪在450nm 波长下测定吸光度(OD 值),计算样品浓度。

样品收集、处理及保存方法

1. 血清:使用不含热原和内毒素的试管,操作过程中避免任何细胞刺激,收集血液后,3000转离心10分钟将血清和红细胞迅速小心地分离。

2. 血浆:EDTA、柠檬酸盐或肝素抗凝。3000转离心30分钟取上清。

3. 细胞上清液:3000转离心10分钟去除颗粒和聚合物。

4. 组织匀浆:将组织加入适量生理盐水捣碎。3000转离心10分钟取上清。

5. 保存:如果样本收集后不及时检测,请按一次用量分装,冻存于-20℃,避免反复冻融,在室温下解冻并确保样品均匀地充分解冻。

自备物品

1.     酶标仪(450nm

2.     高精度加样器及枪头:0.5-10uL2-20uL20-200uL200-1000uL

3.     37恒温箱

操作注意事项

1. 试剂盒保存在2-8,使用前室温平衡20分钟。从冰箱取出的浓缩洗涤液会有结晶,这属于正常现象,水浴加热使结晶溶解后再使用。

2. 实验中不用的板条应立即放回自封袋中,密封(低温干燥)保存。

3. 预处理后的样本无需稀释,直接取10μL加样即可。

4. 严格按照说明书中标明的时间、加液量及顺序进行温育操作。

5. 所有液体组分使用前充分摇匀。

试剂盒组成

名称

96孔配置

48孔配置

备注

微孔酶标板

12孔×8

12孔×4

标准品(1600 pg/ml

0.6mL

0.6mL

按说明书进行稀释

标准品稀释液

6mL

3mL

样本稀释液

6mL

3mL

检测抗体-HRP

10mL

5mL

20×洗涤缓冲液

25mL

15mL

按说明书进行稀释

底物A

6mL

3mL

底物B

6mL

3mL

终止液

6mL

3mL

封板膜

2

2

说明书

1

1

自封袋

1

1

注:标准品用标准品稀释液依次稀释为:160080040020010050 pg/mL.

试剂的准备

 20×洗涤缓冲液的稀释:蒸馏水按120稀释,即1份的20×洗涤缓冲液加19份的蒸馏水。

洗板方法

1. 手工洗板:甩尽孔内液体,每孔加满洗涤液,静置1min后甩尽孔内液体,在吸水纸上拍干,如此洗板5次。

2. 自动洗板机:每孔注入洗液350μL,浸泡1min,洗板5次。

操作步骤

1. 从室温平衡20min后的铝箔袋中取出所需板条,剩余板条用自封袋密封放回4℃。

2. 设置标准品孔、样本孔和空白孔,空白孔什么都不加;标准品孔各加不同浓度的标准品50μL

3. 待测样本孔先加待测样本10μL,再加样本稀释液40μL

4. 随后标准品孔和样本孔中(空白孔不加)加入辣根过氧化物酶(HRP)标记的检测抗体100μL,,用封板膜封住反应孔,37℃水浴锅或恒温箱温育60min

5. 弃去液体,吸水纸上拍干,每孔加满洗涤液,静置1min,甩去洗涤液,吸水纸上拍干,如此重复洗板5次(也可用洗板机洗板)。

6. 所有孔加入底物AB50μL37℃避光孵育15min

7. 所有孔加入终止液50μL15min内,在450nm波长处测定各孔的OD值。

结果判断

 绘制标准曲线:在Excel工作表中,以标准品浓度作横坐标,对应OD值作纵坐标,绘制出标准品线性回归曲线,按曲线方程计算各样本浓度值。

试剂盒性能

1.  性:标准品线性回归与预期浓度相关系数R值,大于等于0.9900

2.  灵敏度:检测浓度小于10 pg/mL

3.  特异性:不与其它可溶性结构类似物交叉反应。

4.  重复性:板内、板间变异系数均小于15%

5.  贮藏:2-8,避光防潮保存。

6.  期:6个月

免责声明

1.   试剂盒仅供研究使用,不得用于临床实验或人体实验,否则所产生的一切后果,由实验者承担,本公司概不负责。

2.   严格按照说明书操作,实验者违反说明书操作,后果由实验者承担。

 

 

FOR RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

Rat growth differentiation factot15 (GDF15) ELISA Kit instruction

 

Intended use

This GDF15 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of GDF15 in the sample, this GDF15 ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus GDF15 concentration. The concentration of GDF15 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Sample collection and storages

Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 10 minutes at approximately 3000×g. Remove serum and assay immediately or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 30 minutes at 3000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

Note: The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.

Materials required but not supplied

1. Standard microplate reader(450nm)

2. Precision pipettes and Disposable pipette tips.

3. 37 ℃ incubator

Precautions

1.  Do not substitute reagents from one kit to another. Standard, conjugate and microplates are matched for optimal performance. Use only the reagents supplied by manufacturer.

2. Do not remove microplate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

3.  Mix all reagents before using.

Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C

Materials supplied

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard1600 pg/mL

0.6ml

0.6ml

Standard diluent

6.0ml

3.0ml

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note: Standard diluent with Standard diluent concentration was followed by:

160080040020010050 pg/mL.

Reagent preparation

20×wash solution:Dilute with Distilled or deionized water 1:20.

 

 

Assay procedure

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add standard: Set Standard wells, testing sample wells. Blank well doesn’t add anyting. Add standard 50μl to standard well.

3. Add Sample: Blank well doesn’t add anyting. Add testing sample 10μl Then add sample diluent 40μl to testing sample well.

4. Blank well doesn’t add anyting. Add 10l of HRP-conjugate reagent to standard wells and sample wells, cover with an adhesive strip and incubate for 60 minutes at 37°C.

5.  Aspirate each well and wash, repeating the process four times for a total of five washes. Wash by filling each well with Wash Solution (400μl) using a squirt bottle, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Solution by aspirating or decanting. Invert the plate and blot it against clean paper towels.

6.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

7.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not

 

appear uniform, gently tap the plate to ensure thorough mixing.

8.  Read the Optical Density O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

Calculation of results

1.         This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.

2.         First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.

3.         To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.

4.         Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

5.         The sensitivity by this assay is 10 pg/mL.

6.         Standard curve

 

Storage 2-8.

validity six months.

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

 

该公司产品分类: LNP相关质粒 双荧光素酶质粒 腺相关病毒质粒 腺病毒质粒 慢病毒质粒 干扰质粒 骨架载体 质粒 沉淀试剂盒 细胞分选试剂盒 技术服务 生化试剂盒 细胞培养板 细胞培养皿 细胞培养瓶 血清移液管 深孔板 普通吸头 实验耗材 PCR板

上海日泉100JYWQ100-15-1600-11系列无堵塞管道式排污泵

 

 ■ 使用条件
 
     、泵的使用环境温度≤40℃,湿度≤95%;海拔高度≤1000米。A
    B、介质温度不超过60℃,介质重度为1~1.3kg/dm3。
    C、铸铁材质的使用范围这PH5~9。
    D、不锈钢材质可使用一般腐蚀性介质。
    E、使用环境海拔高度不超过1000米,超过以上条件时,应在订货时提出,以便为您提供更可靠的产品。
注:用户如有特殊的温度,介质等要求,请在订货时注明输送介质的详细情况,以便本单位提供更为可靠之产品。
 
■ 产品特点
 
 1、采用双叶片叶轮结构,大大提高了污物的通过能力
2、机械密封采用新型磨檫副,并长期处入油室内运行;
3、整体结构紧凑、体积小、燥声小、节能效果显著,检修方便,方便用户更换;
4、自动控制柜可以根据所需液化变化,自动控制泵的超动与停止,不需专人看管,使用极为方便;
5、可根据用户需要配备安装方式,它给安装、维修到来极大的方便,人可不必此为而进入污水坑;
6、能够在设计范围内使用,而保证电机不会过载;
7、该泵配上户外性电机,则无须建泵房,可直接安装与户外使用节省开支;
该公司产品分类: 磁力泵 管道泵 卧式多级消防喷淋泵 立式多级消防喷淋泵 QWP不锈钢排污泵 JPWQ系列自动搅匀潜水排污泵 排污泵 I-1B浓浆泵 螺杆泵 ISWHR卧式不锈钢热水管道增压泵 ISG-单级单吸管道离心泵 型号 消防泵 离心泵 离心泵 水泵

15mW, 30mW激光二极管模块

此类激光二极管模块是带单模态光纤尾纤的高稳定度激光二极管模块,这些模块是用于高速光通信系统和测量仪器最理想的光源。
 
特性:
每小时功率稳定性- <0.02dB
模块输出- <2 minutes
LD工作哦电压- <1.5 V
内置InGaAs监控光电二极管
监控光电二极管电流 >0.2mA
跟踪误差- <± 0.8 dB
极值标准
LD反向电压 2v
PD反向电压 20v
安全工作温度 -20~+50°c
储存温度        -30~+60°c
参数
电/光学 性能 (SM,T=25°c
型号                          波长nm                阈值电流mA          工作电流mA          斜率效率           上升和下降时间       输出功率
                                                                                                                 mW/mA              nom   max
LDI H-FP-1310-30P         1310 ± 20              6                         <120                >0.24                 0.3    0.5                  30
 
LDI H-DFB-1310-30P        1310 ± 20             6                         <120                >0.24                 0.1    0.2                  30
 
LDI H-FP-1550-15P          1550 ± 20             8                         <120                >0.16                0.3     0.5                  15
 
LDI H-DFB-1550-15P       1550 ± 20              8                         <120                >0.16                 0.08 0.12                15
需要更详细的咨询,请与迈可诺中国营销服务中心联系
Tel:021-51078515(上海) 010-52914751(北京) 027-50486618(武汉) Toll Free:400-8800-298 Email:sales@cro.com.cn

玻璃转子流量计 G10-15F 测气体液体流量

 G10-15玻璃转子流量计 铝合金材质螺纹连接 外观精美首选常州良邦

 

水处理专用流量计

流量选择:

测液体:400-4000L/h  630-6300L/h  1-10M3/h  

 

测气体:  12-120m3/h  20-200M3/h

 

口径:15mm

 

材质 :外壳碳钢   接头304不锈钢材质 螺纹连接 (可订做卫生卡箍连接)

G10-15玻璃转子流量计 铝合金材质螺纹连接 外观精美首选常州良邦?    

    VA10型玻璃转子流量计最大工作压力和最高工 作温度均高于原有相同通径的LZB/LZJ系列玻璃转子流量计产品;分普通型(测量一般无腐蚀流体)和耐腐型(测量的腐蚀性流体)两种。产品体积小、结构轻巧,外形美观,维修方便、安全可靠,安装简单。F10、20、30型法兰可转动,与现场管道法兰孔吻合。   VA/FA 型玻璃转子流量计可替代引进成套设备上的玻转仪表,广泛应用于化工、轻工、制药、食品、造纸、环保和计量测试、科研等部门,测量单相非脉动流体(液体或气体)的流量。

G10-15玻璃转子流量计 铝合金材质螺纹连接 外观精美首选常州良邦

该公司产品分类: 涡街流量计 磁翻板液位计 电磁流量计 金属管浮子流量计 玻璃转子流量计 涡轮流量计
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 最新产品

    热门仪器: 液相色谱仪 气相色谱仪 原子荧光光谱仪 可见分光光度计 液质联用仪 压力试验机 酸度计(PH计) 离心机 高速离心机 冷冻离心机 生物显微镜 金相显微镜 标准物质 生物试剂