细胞因子
血清
Elisa试剂盒
- 人Elisa试剂盒
- 小鼠Elisa试剂盒
- 大鼠Elisa试剂盒
- 兔Elisa
- 豚鼠Elisa试剂盒
- 猪Elisa试剂盒
- 鸡Elisa试剂盒
- 其他Elisa试剂盒
- 羊Elisa试剂盒
- 植物Elisa试剂盒
- 牛Elisa试剂盒
- 马Elisa试剂盒
- 鸭Elisa试剂盒
- 猫Elisa试剂盒
- 猴Elisa试剂盒
- 犬Elisa试剂盒
- 类人猿Elisa试剂盒
- 药物残留Elisa试剂盒
- 仓鼠Elisa试剂盒
移液器
耗材
试剂
Qiagen
细胞培养基
淋巴细胞分离液
Omega
RD
TBD
植物ELISA试剂盒
多种属试剂盒
试剂盒
检测试剂盒
美国SANCHEZ ELISA 试剂盒
小鼠ELISA试剂盒
化学试剂
中药对照片
中药对照品
Corning耗材
Axygen耗材
联系我们
联系人:梁经理
资料下载
Mouse COX-1 Elisa Kit,小鼠血清环氧酶-1 Elisa试剂盒 英文说明书
Mouse COX-1 Elisa Kit,小鼠血清环氧酶-1 elisa试剂盒 英文说明书
For the quantitative in vitro determination of Mouse cyclooxygenase-1 concentrations in
serum - plasma - celiac fluid - tissue homogenate - body fluid
FOR LABORATORY RESEARCH USE ONLY.
NOT FOR USE IN DIAGNOSTIC PROCEDURES.
This package insert must be read in its entirety before using this product.
ELISA
ENZYME LINKED IMMUNOSORBENT ASSAY
INTENDED USE AND TEST PRINCIPLE
This COX-1 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of COX
SAMPLE COLLECTION AND STORAGES
Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at
Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2
Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at
MATERIALS REQUIRED BUT NOT SUPPLIED
1.
2. Standard microplate reader capable of measuring absorbance at 450 nm
3. Precision pipettes, disposable pipette tips and Absorbent paper
4. Distilled or deionized water
REAGENTS PROVIDED
All reagents provided are stored at 2
| Name | 96 determinations | 48 determinations |
| Microelisa stripplate | 12*8strips | 12*4strips |
| Standard(6 vial) | 0.5ml/vial | 0.5ml/vial |
| Sample diluent | 6.0ml | 3.0ml |
| HRP-Conjugate reagent | 10.0ml | 5.0ml |
| 20X | 25ml | 15ml |
| Chromogen Solution A | 6.0ml | 3.0ml |
| Chromogen Solution B | 6.0ml | 3.0ml |
| Stop Solution | 6.0ml | 3.0ml |
| Closure plate membrane | 2 | 2 |
| User manual | 1 | 1 |
| Sealed bags | 1 | 1 |
Note:
1. Standard concentration was followed by: 120、60、30、15、7.5、3.75 U/L.
2. If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.
PRECAUTIONS
1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
2. Allow kit reagents and materials to reach room temperature (20
3. Do not use kit components beyond their expiration date.
4. Use only deionized or distilled water to dilute reagents.
5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2
6. Use fresh disposable pipette tips for each transfer to avoid contamination.
7. Do not mix acid and sodium hypochlorite solutions.
8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
9. All samples should be disposed of in a manner that will inactivate viruses.
10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20
REAGENT PREPARATION AND STORAGE
Wash Solution (1X) - Dilute 1 volume of
ASSAY PROCEDURE
1. Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.
2. Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.
3. Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with anadhesive strip and incubate for 60 minutes at
4. Wash the Microtiter Plate 4 times.
Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.
Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.
5. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at
6. Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.
7. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.
CALCULATION OF RESULTS
1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.
2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.
3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.
6. Assay range: 3.75 U/L – 120 U/L.
7. Sensitivity: The minimum detectable dose of Mouse COX-1 is typically less than 1.0 U/L.
8. Cross-reactivity: This assay recognizes recombinant and natural Mouse COX-1. No significant cross-reactivity or interference was observed.
9. Storage: 2
10. Standard curve
FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS!PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!
相关文章
- 2016/3/9大鼠肿瘤坏死因子α(TNF-α)ELISA检测试剂盒
- 2016/3/9小鼠高铁血红蛋白(MHB)ELISA试剂盒原理
- 2015/5/18促销犬BRD4酶联免疫分析试剂盒
- 2015/5/18人P物质(SP)酶联ELISA试剂盒资料下载
- 2015/5/18人白细胞介素1β(IL-1β)酶联免疫说明书
- 2014/10/31elisa实验过程中影响的因素
- 2014/10/31胎牛血清质量要求有哪些?
- 2014/10/27现货大鼠极低密度脂蛋白试剂盒使用方法
- 2014/10/27拟除虫菊酯酶联免疫分析(ELISA)试剂盒注意事项说明
- 2014/10/24ELISA试剂盒的常见种类您了解多少?




