二、UV紫外线老化测试仪技术指标:
型号:HE-UV8
1、工作室尺寸:400mm×1140mm×380mm (D×W×H)
2、外形尺寸:500mm×1300mm×1460mm (D×W×H)
3、紫外灯管参数:
3-1灯管型号:UV-A(315~400nm)、UV-B(280~315nm)任选
3-2灯管品牌:美国原装进口ATALS
3-3灯的中心距离:70mm
3-4辐射强度:0.4W/m2~1W/m2以内可调(另选购)
4、试验箱温度指标:
4-1光照温度范围:50℃~70℃
4-2冷凝温度范围:40℃~60℃
4-3光照温度容差:≤±2℃
4-4温度波动度≤±2℃
4-5温度解析度:0.1℃
5、黑板温度计
5-1测量范围:30~80℃
5-2容差为±1℃
6、湿度范围:45%~90%R.H
7、控温方式:PID自整定控温方式
8、水槽要求:水深不大于25mm,并有供水自动控制器
9、样品架:2套
9-1标准试件尺寸:75×90mm(可定做特殊规格样品架)
9-2测试能力:48片
9-3试件离灯表面的最近平行面距离:50mm
9-4样品的最大厚度:20mm
三、UV紫外线老化测试仪符合标准:GB/T14552-2008、GB/T16422.3-1997 GB/T16585-96、GB/T16585-1996、GB/T16422.3-1997、:ASTM D4329、ISO 4892-3、ISO 11507、SAE J2020等
型 号Model | R R N | |||||
100 | 150 | 225 | 408 | 800 | 1000 | |
温度范围Temp.range | RT+10℃~300℃ | |||||
湿度范围Humidity Range | 30~98%.R.H | |||||
温度偏差Temperature deviation | ±2.0℃ | |||||
温度波动度Temperature Constancy | ±0.5℃ | |||||
升温时间Heat up time | 20℃~200℃约55分钟以内Within 55min | |||||
内箱尺寸Internal dimension(W×H×Dcm) | 40×50×50 | 50×60×50 | 50×75×60 | 60×75×60 | 100×100×80 | 100×100×100 |
外箱尺寸External dimension(W×H×Dcm) | 100×150×110 | 105×150×110 | 105×165×120 | 115×175×140 | 160×190×140 | 160×190×160 |
功率(kw) | 5.5kw | 7kw | 4.5kw | 5.5kw | 6.5kw | 6.5kw |
控制器Controllor | 进口温度控制器、进口可编程温度控制器 | |||||
温度传感器Temperature sensor | Pt100铂电阻 | |||||
加热器Heater | 镍铬合金电加热器 | |||||
循环系统Circulatory system | 耐高温低噪音空调型电机,多叶式离心风轮 | |||||
内箱材质Internal material | SUS304不锈钢板 | |||||
外箱材质External material | SUS304不锈钢板或钢板静电喷涂表面处理 | |||||
保温材质Insulation material | 聚胺脂硬质发泡、超细玻璃纤维绵 | |||||
标准配件Standard Accessories | 试品架2个、转盘一个、固定式PU活动轮 | |||||
保护装置Safety Devices | 漏电、短路、超温、电机过热、过电流保护 | |||||
电源功率Power | AC380V±10% 50±0.5Hz 三相五线制 | |||||
使用环境温度Ambient Temp | 5℃~+30℃ ≤85%R.H | |||||
备 注: 1、以上数据均在环境温度(QT)25℃.工作室无负载条件下测得; 2、可选依根据客户要求来定做双层转盘; 3、本技术信息,如有变动恕不另行通知。 |
紫外光加速老化试验机,紫外线加速耐候试验机,紫外光耐气候试验箱,紫外老化测试仪
Q8/UV紫外光加速老化试验机Q8/UV紫外光加速老化试验机主要用于模拟对阳光、潮湿和温度对材料的破坏作用;材料老化包括褪色、失光、强度降低、开裂、剥落、粉化和氧化等。紫外光加速老化试验机通过模拟阳光、冷凝、模仿自然潮湿,试样在模拟的环境中试验几天或几周的时间,可再现户外可能几个月或几年发生的损坏。Q8/UV紫外光加速老化试验机中,紫外灯的荧光紫外等可以再现阳光的影响,冷凝和水喷淋系统可以再现雨水和露水的影响。整个的测试循环中,温度都是可控的。典型的测试循环通常是高温下的紫外光照射和相对湿度在100%的黑暗潮湿冷凝周期;典型应用在油漆涂料、汽车工业、塑胶制品、木制品、胶水等。 模拟阳光阳光中的紫外线是造成大多数材料耐久性能破坏的主要因素。我们使用紫外灯来模拟阳光中的短波紫外部分,它产生很少的可见光或红外光谱能量。我们可以根据不同的测试要求选择不同波长的UV紫外灯,因为每种灯在总的紫外线辐照能量和波长都不一样。www.oven.cc 通常,UV灯管可分为UVA和UVB两种。Q8/UV灯管UVA-340灯管:UVA-340 灯管可极好地模拟太阳光中的短波紫外光,即从365 纳米到太阳光截止点 295 纳米的波长范围。UVB-313灯管:UVB-313 灯管发出的短波紫外光比通常照射在地球表面的太阳紫外线强烈,从而可以最大程度的加速材料老化。然而,该灯管可能会对某些材料造成不符合实际的破坏。UVB-313 灯管主要用于质量控制和研究开发,或对耐候性极强的材料运行测试。UVA-351灯管:模拟透过窗玻璃的阳光紫外光,它对于测试室内材料的老化最为有效。
潮湿冷凝环境在很多户外环境中,材料每天的潮湿时间可长达12小时。研究表明造成这种户外潮湿的主要因素是露水,而不是雨水。Q8/UV通过独特的冷凝功能来模拟户外的潮湿侵蚀。在试验过程中的冷凝循环中,测试室底部蓄水池中的水被加热以产生热蒸气,并充满整个测试室,热蒸汽使测试室内的相对湿度维持在100%,并保持一个相对高温。试样被固定在测试室的侧壁,从而试样的测试面曝露在测试室内的环境空气中。试样向外的一面暴露在自然环境中具有冷却效果,导致试样内外表面具备温差,这一温差的出现导致试样在整个冷凝循环过程中,其测试面始终有冷凝生成的液态水。由于户外曝晒接触潮湿的时间每天可以长达十几小时,因此典型的冷凝循环一般持续几个小时。Q8/UV提供两种潮湿模拟方法。应用最多的是冷凝方法,它是模拟户外潮湿侵蚀的最好方法。所有的Q8/UV型号都可运行冷凝循环。因为有些应用条件也要求使用水喷淋以达到实际的效果,所以有些Q8/UV型号既可运行冷凝循环又可运行水喷淋循环。
温度控制在每个循环中,温度都可控制在一个设定值。同时黑板温度计可以监控温度。温度的提高可以加速老化的进程,同时,温度的控制对于测试的可再现性也是很重要的。
水喷淋系统对于某些应用而言,水喷淋能更好地模拟最终使用的环境条件。水喷淋在模拟由于温度剧变和由于雨水冲刷所造成的热冲击或机械侵蚀是非常有效的。在某些实际应用条件下,例如阳光下,聚集的热量由于突降的阵雨而迅速消散时,材料的温度就会发生急剧变化,产生热冲击,这种热冲击对于许多材料而言是一种考验。Q8/UV的水喷淋可以模拟热冲击和/或应力腐蚀。喷淋系统有12个喷嘴,在测试室的每一边各有6个;喷淋系统可运行几分钟然后关闭。这短时间的喷水可快速冷却样品,营造热冲击的条件。
照射强度控制:可选选配照射强度控制选件可得到精确型和重复性好的测试结果;光强控制系统允许用户根据不同的测试要求设置不同的光照强度。通过其反馈回路装置精确控制照射强度;同时也可以延长荧光灯的使用寿命
Q8/UV紫外光加速老化试验机主要技术指标
型号 Model | Q8/UV3 | Q8/UV2 | Q8/UV1 |
UV 照射 Exposure | ● | ● | ● |
冷凝 Condensation | ● | ● | ● |
光照控制 Irradiancs Control | ● | ● |
|
可调光线 Adjustable irradiance | ● | ● |
|
喷水 Water Spray | ● |
|
|
热冲击 Thermal Shock | ● |
|
|
自动侦路 Self-diagnostics | ● | ● | ● |
灯泡数量 Lamp Q'ty | 紫外线灯管 8 支,备品 4 支 Ultravloiet lamp 6pcs, spares 4 pcs (美国Q-LAB,Q-Panel,美国ATLAS,UVA340,UVB313,UVC351) | ||
记录器 Recorder | 选配 (Optional) | ||
辐射计 Q8-CR Calibration Radiometer | 选配 (Optional) 机器辐射强度: 1.0W/m2/340nm以内可调 1.1W/m2/313nm以内可调 | ||
UV 温度 Temp | 50 ℃ -75 ℃ | ||
冷凝温度 Condensation Temp | 40 ℃ -60 ℃ | ||
测试容量 Test Capacity | 48pcs 片/se spray( 75 x 150m m ) 50pcs片/basic ( 75 x 150m m ) | ||
水凉及耗量 Water | 蒸馏水每分钟 蒸馏水每日 8 公升 | ||
体积 Dimension(W x D x H) | 137 x 53 x 136cm | ||
重量 Weight | 136kg | ||
电源 Power | 1 ψ , 120V/60Hz,16A or 230V/50Hz, 9A,1800W(max) |
Q8/UV紫外光加速老化试验机测试方法
通用
• ISO 4892-1 Plastics- Methods of exposure to laboratory light sources-Part 1: General Guidance• ASTM G-151, Standard Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources• ASTM G-154, Standard Practice for Operating Fluorescent Light Apparatus for UV Exposure of Non-Metallic Materials• British Standard BS 2782: Part 5, Method 540B (Methods of Exposure to Lab Light Sources)• SAE J2020, Accelerated Exp. of Automotive Exterior Materials Using a Fluorescent UV/Condensation Apparatus• JIS D 0205, Test Method of Weatherability for Automotive Parts (Japan)• GB/T 16422.1,塑料实验室光源暴露试验方法 第1部分:总则________________________________________涂料
• ISO 11507, Paints & varnishes-Exposure of coatings to artificial weathering-Exposure to fluorescent UV and water• ISO 20340, Paints & varnishes –Performance requirements for protective paint systems for offshore andrelated structures• ASTM D-3794, Standard Guide for Testing Coil Coatings• ASTM D-4587, Standard Practice for Light/Water Exposure of Paint• US Government, FED-STD-141B• US Govt., Federal Specification TT-E-489H, Enamel, Alkyd, Gloss, Low VOC Content• US Govt., Federal Specification TT-E-527D, Enamel, Alkyd, Lusterless, Low VOC Content• US Govt., Federal Specification TT-E-529G, Enamel, Alkyd, Semigloss, Low VOC Content• US Govt., Federal Specification TT-P-19D Paint, Latex, Acrylic Emulsion, Ext. Wood & Masonry• NACE Standard TM-01-84 Procedures for Screening Atmospheric Surfaced coatings• GM4367M Topcoat Materials - Exterior• GM 9125P Laboratory Accelerated Exposure of Automotive Material• Korean Standard M5982-1990, Test Method for Accelerated Weathering• Spanish Std, UNE 104-281-88 Accelerated Testing of Paints and Adhesives with Fluorescent UV Lamps• Israeli Standard No. 330, Steel Windows• Israeli Standard No. 385, Plastic Windows• Israeli Standard No. 935, Road Marking Paint• Israeli Standard No. 1086, Aluminum Windows• NISSAN M0007, Fluorescent UV/Condensation Test• JIS K 5600-7-8, Testing Methods for Paints• MS 133: Part F16, Methods of Test for Paints and Varnishes: Part F16: Exposure of Coatings to Artificial Weathering- Exposure to Fluorescent UV and Water (ISO 11507)• NBR-15.380 Paints for buildings–Methods for performance evaluation of paints for non-industrial buildings – Resistance to UV irradiation/water vapor condensation, by accelerated test• prEN 927-6 Paints & varnishes–Coating materials and coating systems for exterior wood – Pt. 6: Exposure of wood coatings to artificial weathering using fluorescent UV and water• GB/T 12967.4,铝及铝合金阳极氧化 着色阳极 氧化膜耐紫外光性能的测定________________________________________纺织品
• AATCC Test Method 186, Weather Resistance: UV Light and Moisture Exposure• ACFFA Test Method for Colorfastness of Vinyl Coated Polyester Fabrics________________________________________印刷油墨• ASTM F1945, Lightfastness of Ink Jet Prints Exposed to Indoor Fluorescent Lighting ________________________________________橡胶• GB/T 16585,硫化橡胶人工气候老化(荧光紫外灯)试验方法________________________________________电工电子产品• GB/T 19394,光伏(PV)组件紫外试验type the link here________________________________________粘合剂和密封剂
• ASTM C 1501, Standard Test Method For Color Stability of Building Construction Sealants as Determined byLaboratory Accelerated Weathering Procedures• ASTM C-1184, Specification for Structural Silicone Sealants• ASTM C-1442, Standard Practice for Conducting Tests on Sealants Using Artificial Weathering Apparatus• ASTM D-904, Standard Practice for Exposure of Adhesive Specimens to Artificial Light• ASTM D-5215, Standard Test Method for Instrumental Evaluation of Staining of Vinyl Flooring by Adhesives• American Plywood Assn., Approval Procedures for Synthetic Patching Materials, Section 6• Spanish Std, UNE 104-281-88 Accelerated Testing of Paints and Adhesives with Fluorescent UV Lamps________________________________________塑料
• ISO 4892 Plastics - Methods of Exposure to Laboratory Light Sources-Part 3: Fluorescent UV Lamps• DIN 53 384, Testing of plastics, Artificial Weathering and Exposure to Artificial Light• Spanish Standard UNE 53.104 (Stability of Plastics Materials Exposed to Simulated Sunlight)• Israeli Standard No. 385, Plastic Windows• JIS K 7350, Plastics - Methods of Exposure to Laboratory Light Sources-Part 3: Fluorescent UV Lamps• ASTM D-1248, Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable• ASTM D-4329, Standard Practice for Light/Water Exposure of Plastics• ASTM D-4674, Test Method for Accelerated Testing for Color Stability of Plastics Exposed to IndoorFluorescent Lighting and Window-Filtered Daylight• ASTM D-5208, Standard Practice for Exposure of Photodegradable Plastics• ASTM D-6662, Standard Specification for Plastic Lumber Decking Boards• ANSI C57.12.28 Specification for Accelerated Weathering of Padmounted Equipment Enclosure Integrity• ANSI, A14.5 Specification for Accelerated Weathering of Portable Reinforced Plastic Ladders• Edison Electrical Inst. Specification for Accelerated Weathering of Padmounted Equip. Enclosure Integrity• Wisconsin Electric Power Specification for Polyethylene Signs• GB/T 18950,橡胶和塑料软管 静态下耐紫外线性能测定• GB/T 16422.3,塑料实验室光源暴露试验方法 第3部分:荧光紫外灯________________________________________屋顶材料
• ASTM D-4799, Test Method for Accelerated Weathering of Bituminous Roofing Materials• ASTM D-4811, Standard Specification for Nonvulcanized Rubber Sheet Used as Roof Flashing• ASTM D-3105, List of Test Methods for Elastomeric and Plastomeric Roofing & Waterproofing• ASTM D-4434, Standard Specification for PVC Sheet Roofing• ASTM D-5019, Standard Specification for Reinforced Non-Vulcanized Polymeric Sheet Used in Roofing Membrane• ANSI/RMA IPR-1-1990 Req. for Non-Reinforced Black EPDM Sheet for Roofing Membrane• ANSI/RMA IPR-2-1990 Req. for Fabric-Reinforced Black EPDM Sheet for Roofing Membrane• ANSI/RMA IPR-5-1990 Req. for Non-Reinforced Non-Black EPDM Sheet for Roofing Membrane• ANSI/RMA IPR-6-1990 Req. for Fabric-Reinforced Non-Black EPDM Sheet for Roofing Membrane• British Standard BS 903: Part A54 Annex A & D, Methods of Testing Vulcanized Rubber• CGSB-37.54-M, Canadian General Standards Board Spec. for PVC Roofing & Waterproofing Membrane• DIN EN 534, Corrugated bitumen sheets• EOTA TR 010, Exposure procedure for artificial weathering• RMA Specification for Reinforced Non-Vulcanized Chlorosulfonated Polyethylene Sheet for Roofing Membrane________________________________________复合材料
• Israeli Standard No. 385, Anodic Coatings on Aluminum________________________________________
参数注解:用途:主要用于电吹风的长时间工作老化测试。可测试电流 试验次数、时间及试验周期等,1,检测工位:6个。2,PLC控制,可根据自身需求设定测试项目及调节电流大小(变频器或调压器客户自备);3,开放式的操作窗口,每组独立控制可设定电流等报警上下限;4,交替运行的样机的工作和停止时间可分别独立调节;5,增加烟雾报警,共2个,有声光报警及自动断电与外接联网功能,前后可调最大范围350mm;6,每工位前面一个负载输出插座。7,电源总输入通过空气开关,≥60A;在控制台下端输入。8,配有漏电保护开关,有过流、过压保护装置。(电压、电流、功率等调节量程取绝于客户提供的变频仪)。9,外部尺寸约:长1100X宽550X高1400MM, 重量约:90Kg,电源:220V/50Hz
高温老化箱产品特点:
采用智能温度调节仪,温度值由变四位数字显示
控温精度高,温度均匀性好。
具有上限超温报警及超温保护功能。
试样搁板为转盘,因而试件温度均匀性好。
高温老化箱产品主要技术参数:
内箱尺寸:50×50×60cm(可定制)
最高温度:常温至-200℃or300℃
试片架回转速度:5~10rpm(可设)
产品体积:101×65×114cm
机台重量:95kg
工作电源:1∮,220V,20A
环境温度:5~40℃;
相对湿度:不大于85%;
气压:86~106kPa;
使用条件:
1.环境温度: 5—40
2.相对湿度:85%R.H
3.大气压力:86-106Kpa
4.电 源:220V 15A 50Hz
5.周围无强烈震动及腐蚀性气体存在
Ci3000 Weather-Ometer氙灯老化测试仪
Ci3000+代表了实验室老化设备方面应用数字、光学技术的最高科技,建立了重复性、重现性和操作效率方面的最新标准。
无与伦比的重复性和重现性:在空气流动、辐照度和控制系统方面的设计和制造革新大大降低了严格试验参数的可变性。结果:Ci3000+可以达到更高的温度、湿度和光照一致性。
更快、更简单的维修,提高实用性:对控制部分、测试箱体、用户可服务部件、诊断屏幕等全部可从正面进入,自动氙灯校准和提升的部件寿命是降低保养时间和成本的巨大进步。
简单的操作:以微处理器为基础的用户界面简化了试验开始步骤,提高了诊断能力,可自动进行校准,对用户自定义测试循环进行简单编程。
可靠的全光谱日光重现:经过证明“Ci”可控辐照氙光灯系统可提供恒定的光能,简单的改换适合氙灯光谱的灯管过滤片来模拟与产品最终使用条件相匹配的不同日晒条件。经过合适过滤的氙灯是目前对自然阳光的最好复制。
满足国际老化和色牢度测试要求:Ci3000+老化仪可满足ASTM,ISO,SAE,CEN,DIN,AATCC,JASO,JIS,BS,AFNOR和其它的国际组织所指定的测试条件。
在简易性和功能性方面达到顶点。Atlas Ci3000+提供了老化和色牢度的解决办法。它提供了广阔的标准和自定义试验编程功能,Smart Light Damper保证光过滤片的合适选择.
窄带或宽带控制,可有选择地监测另一个波长。
对箱体温度和黑板温度即时、自动的闭环控制。
简单安装和快速断开的4500瓦氙灯系统。
温度和湿度的的时间比例闭环控制。
Smart Damper保证整个箱体内环境稳定。
不绝缘(ASTM/ISO)或绝缘(DIN/ISO)黑板传感器均可用来控制/监测试验参数。
Smart Light Damper会阻止操作者在安装了不正确的过滤片时开始或校准试验。
菜单驱动的液晶控制面板简化操作。
与相类似的机器相比,正面与背面进入减少了占地面积。
方便用户和服务技术员进入。
程序储存功能提供了对实际上无限步骤更换进行简单编程的能力。
改良系统控制均匀的空气流动。空气是从下面吸入,而不是吹入增大的箱体中,直接向上经过样品架和样品,不产生湍流,从箱体上部排出。结果:热量和空气在样品暴露区均匀分布。
带专利的Smart Damper系统对温度、湿度进行微调控制。风门和加热器系统的数字比例控制减少测试箱体内的温度和湿度波动。它也可以对实验室环境进行补偿。
带有专利的黑板温度和箱体温度的独立、自动控制。风扇速度和Smart Damper的自动调节可以对箱体和黑板温度进行同时和独立控制。
闭环、时间比例Vibra-Sonic湿度控制。该系统可以在一个更大的操作条件范围内提供比简单的ON/OFF开关系统更敏感、即时的控制。
更坚固的架子稳定样品位置.采用不锈钢和加强设计的精确制造将在试验和样品放置过程中的架子变形减到最低。标准的单层样品架可以容纳各种Atlas样品夹。
正向灯管样架对直系统提供精确的样品同心性。重新设计的灯管和样架装配提供更好的对直性。灯管装配时独一无二的球体与灯座连接可精确调节灯管来保证同心对直。
灯管定位锁保证灯管指向重复性。灯管装配定位栓保证对工作灯管和校准灯管相对于光监测器的可重复定位。产生更高的校准和操作精度。
闭环辐照度控制系统。在每个试验过程中对辐照量进行恒定的测量和控制保证在灯管寿命内的均匀暴晒。
可选的CIRA(涂层红外吸收)过滤片提高重复性和重现性。特殊的涂层内过滤片提供更好的阳光模拟和稳定的透射率。它的寿命是现存的Atlas内过滤片的5倍。
有些国际标准要求窄带辐照控制,另一些要求宽带控制。Ci3000+老化箱可以选择在控制任一波长模式时监测另一个。
标准操作范围扩展试验选择性。Ci3000+提供在340nm,420nm,300-400nm控制和监测的能力。它提供超过2个太阳辐照量水平的能力和可选的冷冻设备拓宽了试验温度范围。
强有力的控制器提供更强的测试能力、适用性和控制。
针对用户配置的性能和选项提供宽阔的适应性。窄带或宽带光监测,第二黑板或白板温度测量,各种不同的样品夹,对多达三个样架感应器的收集环,2个太阳的辐照量水平,多种氙灯光过滤片及宽广的箱体温度和黑板温度操作范围拓宽了适应性。
快速选择标准测试程序。通过简单的按键从内存中选择标准程序和用户自定义程序。
快速、简易的试验设置和监测。菜单驱动屏幕引导按键进入参数值。多重监测屏幕可随时浏览试验数据。
厂方安装的标准的试验参数。多达12个工厂编制的、普遍使用的褪色和老化试验序列。用户可以定义、编制和储存5个另外的序列。
Smart Damper Monitor保证精确的操作。对宽带和窄带过滤片进行电子辨认。程序保证在操作以前安装正确的过滤片。
可以容纳多种样品夹。各种不同形状和尺寸的样品可以装在样品架上而不碰到箱体内壁。不规则形状的样品、很薄的弹性膜样品、拉伸棒、标准基材上的涂层、受张力的材料、纺织品布料、塑料片和瓶子都可以装在标准和特制的样品夹上。
方便、快速地进行服务。主要的保养项目从正面进行。所有的外部面板都可以方便地移走。滑出控制面板可以接触到许多电子部件。新式的装灯设计简化了灯管安装和保养。
屏幕显示诊断信息。诊断屏幕告诉用户预防性的保养和校准要求。提供准确的提示来解决问题。
自动辐照度校准节约时间。菜单驱动软件进行有效和精确的校准。典型的过程在15分钟内完成。
在有计划的、自动的辐照度校准过程中保存和恢复正在进行的试验。控制器可以保存正在进行中的试验数据,并从校准中断前的同一点完成试验。
更长的灯管寿命。经过证明,氙灯的平均使用寿命超过2000小时。稳定的内外过滤片有类似的寿命,减少灯管和过滤片的更换。
节约空间的设计。对控制、测试箱体、用户服务部件的全部正面进入节约了宝贵的实验室空间。这种设计使多种元件方便定位。
安静、安全的操作。设计上的革新降低了整个试验中的噪音。电子部件独立于高功率的交流电路系统以达到最大的可靠性。用户程序中的黑板温度和箱体温度限制当超过设定值时关闭机器以保护样品。可以提供符合CE要求的型号。
便于进入、自动充满的灯管冷却水箱。水箱自动保持水位。抽屉式的设计便于清洁和保养。
Ci3000+老化箱可选件
六通道记录仪。6通道图表记录仪提供即时显示,并可同时打印多达6个参数的变化趋势曲线。
数据采集和联网。即将实现通过RS232,RS422/RS485,SNP,SNP-X,RTU或CCMII等系列接口从一台机器或联网的多台机器上下载数据到个人电脑上。
LiquiAirTM。LiquiAir热交换器可减少Ci3000+氙灯冷却系统对自来水的需求,该系统采用室内外的空气来冷却氙灯水。
反渗透系统。Atlas ARO系统携带完备的过滤器和控制,提供满足或超过最新要求的水,包括ASTM标准。
空气冷冻机。空气冷冻系统可在标准的Ci3000+功能上扩展温度和湿度范围。
附属过滤片系统。对一些国际标准和研究与发展需要来说,采用Atlas氙灯过滤系统可以进一步提高氙灯光谱能量分布。在该系统中可以安装不同光谱透射的6种可交换过滤片。
针对实际环境中样品温度的氙灯科技。太阳光子提供从紫外到红外范围的光能。不能提供红外能量的人造光源不能将样品加热到象在真实环境中由于长波红外存在时的状态。对长波红外的吸收使样品温度比在空气中要高。估计在老化降解过程中温度的重要性为:温度上升10C,动力学反应速率加快1倍。
Ci3000+技术参数:
光源: 4500W水冷氙弧灯
平均灯管寿命: 2000小时
灯管过滤器: 可交换的内外过滤片
辐照度控制: 自动微机控制
湿度控制: 用相对湿度传感器进行自动比例控制
湿度范围: 亮周期:10-75%(依赖温度)暗周期:最高到100%
温度控制: 用Smart Damper系统自动控制
黑板温度范围: BPT:40-110℃ BST:40-120℃
样品架类型: 单层精确设计
总的暴露面积: 2188cm2
样品夹: 20个(70×145×3mm)
电源要求: 3相4线,380V,50Hz,38A
水压力: 138-344Kpa
水流量(最大) 纯水 自来水@18.5℃
湿度 0.12L/min
样品喷淋 0.07L/min
样品架喷淋 0.07L/min
CS-6灯管冷却@7000W @1.5L/min
压缩空气: 0.11m3/分钟,550kPa
机器尺寸: 183高×95宽×87深(厘米)
占地面积: 105×203厘米
地板承重: 404Kg