sun hydraulics线圈770-912
sun hydraulics,SUN插装阀,SUN顺序阀,SUN插式阀,SUN抗衡阀,SUN电磁阀,SUN泄压阀,SUN方向阀,SUN泄压阀,SUN平衡阀,SUN流量控制阀,SUN回路节省阀,SUN电磁阀线圈
厦门纳广贸易有限公司优势供应美国sun hydraulics(太阳)产品
电话:
手机:13799789877
传真:
网址:www.xmngmy.com
美国SUN线圈技术特点:
线圈绕线为H级, (356度F, [189度C] 规格)以确保高性的連续动作.
突波器直接模塑于线圈以防止突波影响, 保护已連接电路. .
线圈的金属外殻对物理性的损伤有较佳的保护作用.
欲获得的比例控制性能,请使用具有电流感应和抖振信号调整的比例放大器, 抖振信号应调设在 100-250Hz.
部分型号例举如下:
sun hydraulics线圈760-206
sun hydraulics线圈760-211
sun hydraulics线圈760-212
sun hydraulics线圈760-223
sun hydraulics线圈760-224
sun hydraulics线圈760-506
sun hydraulics线圈760-512
sun hydraulics线圈760-524
sun hydraulics线圈760-706
sun hydraulics线圈760-712
sun hydraulics线圈760-724
sun hydraulics线圈770-612
sun hydraulics线圈770-548
sun hydraulics线圈770-512
sun hydraulics线圈770-299
sun hydraulics线圈770-248
sun hydraulics线圈770-214
中国仪器仪表销售网:www.yiqiyibiao.com
压力表具有抗介质脉动和冲击载荷,耐环境振动等特性,适用测量对铜和铜合金无腐蚀性的气体,液体或蒸 汽等压力。仪表设上、下限二位开关型接点装置,在压力达到设定值时发出信号或通断控制电路,供作业系统自动控制或发讯用。其抗振结构可抑制指针的抖动、冲击,保护接点,使仪表指示清晰,电信号切换,工作稳定。广泛应用于机械、化工、石油、冶金、电力等工业生产过程。技术参数:
型号 | YTXC-100ZQ-Z | YTXC-150ZQ-Z | YTXC-100-Z | YTXC-150-Z | YTXC-100TQ-Z | YTXC-150TQ-Z | |
结构形式 | 轴向带前边 | 径向无边 | 径向带前边 | ||||
测量范围 MPa | -0.1-0.15;-0.1-0.3;-0.1-0.5;-0.1-0.9;-0.1-1.5;-0.1-2.4 0-0.25; 0-0.4; 0-0.6; 0-1.0; 0-1.6; 0-2.5; 0-4.0; 0-6.0; 0-10; 0-16; 0-25; 0-40; 0-60 | ||||||
精确度% | ± 1.6 | ||||||
接点电参数 | 工作电压 | 380VAC;220VDC | |||||
最大工作电流 | 1A | ||||||
持续电流 | 0.6A | ||||||
最大功率 (无感负载) | 20VA | ||||||
连接器 | X14K4P | 防水接线盒 | X14K4P | 防水接线盒 | X14K4P |
使用工作温度:-25℃~55℃工作压力上限:不大于仪表上限的2/3工作环境振动频率不大于25Hz,振幅不大于0.5mm仪表执行标准:Q/320211 DGH05-2004
外形尺寸:
型号 | 外形尺寸mm | ||||||||||
D | D1 | D2 | D3 | A | B | C | E | d | d0 | M | |
YTXC-100-Z | 100 | 120 | 96 | / | 44 | 38 | / | 12.5 | / | / | 20×1.5 |
YTXC-100ZQ-Z | 100 | 130 | 96 | / | 42 | 33 | 34 | 8.5 | 118 | 5.6 | |
YTXC-100TQ-Z | 100 | 125 | 96 | 102 | 44 | 38 | / | 9.5 | 118 | 5.6 | |
YTXC-150-Z | 150 | 164 | 136 | / | 50 | 44 | / | 16 | / | / | |
YTXC-150ZQ-Z | 150 | 177 | 136 | / | 50 | 43 | 55 | 14 | 165 | 5.6 | |
YTXC-150TQ-Z | 150 | 177 | 136 | 144 | 50 | 44 | / | 18 | 165 | 5.6 |
人甲基睾丸酮(Methyltestosterone)ELISA检测试剂盒
本试剂盒仅供研究使用。
人甲基睾丸酮(Methyltestosterone)ELISA检测试剂盒实验原理
本试剂盒应用双抗体夹心法测定标本中人甲基睾丸酮(Methyltestosterone)水平。用纯化的人甲基睾丸酮(Methyltestosterone)抗体包被微孔板,制成固相抗体,往包被单抗的微孔中依次加入甲基睾丸酮(Methyltestosterone),再与HRP标记的甲基睾丸酮(Methyltestosterone)抗体结合,形成抗体-抗原-酶标抗体复合物,经过彻底洗涤后加底物TMB显色。TMB在HRP酶的催化下转化成蓝色,并在酸的作用下转化成最终的黄色。颜色的深浅和样品中的甲基睾丸酮(Methyltestosterone)呈正相关。用酶标仪在450nm波长下测定吸光度(OD值),通过标准曲线计算样品中人甲基睾丸酮(Methyltestosterone)浓度。
人甲基睾丸酮(Methyltestosterone)ELISA检测试剂盒试剂盒组成
1 | 30倍浓缩洗涤液 | 20ml×1瓶 | 7 | 终止液 | 6ml×1瓶 |
2 | 酶标试剂 | 6ml×1瓶 | 8 | 标准品(96 nmol/L) | 0.5ml×1瓶 |
3 | 酶标包被板 | 12孔×8条 | 9 | 标准品稀释液 | 1.5ml×1瓶 |
4 | 样品稀释液 | 6ml×1瓶 | 10 | 说明书 | 1份 |
5 | 显色剂A液 | 6ml×1瓶 | 11 | 封板膜 | 2张 |
6 | 显色剂B液 | 6ml×1/瓶 | 12 | 密封袋 | 1个 |
标本要求
1.标本采集后尽早进行提取,提取按相关文献进行,提取后应尽快进行实验。若不能马上进行试验,可将标本放于-20℃保存,但应避免反复冻融
2.不能检测含NaN3的样品,因NaN3抑制辣根过氧化物酶的(HRP)活性。
人甲基睾丸酮(Methyltestosterone)ELISA检测试剂盒操作步骤
1. 标准品的稀释:本试剂盒提供原倍标准品一支,用户可按照下列图表在小试管中进行稀释。
48 nmol/L | 5号标准品 | 150μl的原倍标准品加入150μl标准品稀释液 |
24 nmol/L | 4号标准品 | 150μl的5号标准品加入150μl标准品稀释液 |
12 nmol/L | 3号标准品 | 150μl的4号标准品加入150μl标准品稀释液 |
6 nmol/L | 2号标准品 | 150μl的3号标准品加入150μl标准品稀释液 |
3 nmol/L | 1号标准品 | 150μl的2号标准品加入150μl标准品稀释液 |
2. 加样:分别设空白孔(空白对照孔不加样品及酶标试剂,其余各步操作相同)、标准孔、待测样品孔。在酶标包被板上标准品准确加样50μl,待测样品孔中先加样品稀释液40μl,然后再加待测样品10μl(样品最终稀释度为5倍)。加样将样品加于酶标板孔底部,尽量不触及孔壁,轻轻晃动混匀。
3. 温育:用封板膜封板后置37℃温育30分钟。
4. 配液:将30倍浓缩洗涤液用蒸馏水30倍稀释后备用
5. 洗涤:小心揭掉封板膜,弃去液体,甩干,每孔加满洗涤液,静置30秒后弃去,如此重复5次,拍干。
6. 加酶:每孔加入酶标试剂50μl,空白孔除外。
7. 温育:操作同3。
8. 洗涤:操作同5。
9. 显色:每孔先加入显色剂A50μl,再加入显色剂B50μl,轻轻震荡混匀,37℃避光显色15分钟.
10. 终止:每孔加终止液50μl,终止反应(此时蓝色立转黄色)。
11. 测定:以空白空调零,450nm波长依序测量各孔的吸光度(OD值)。 测定应在加终止液后15分钟以内进行。
操作程序总结:
计算
以标准物的浓度为横坐标,OD值为纵坐标,在坐标纸上绘出标准曲线,根据样品的OD值由标准曲线查出相应的浓度;再乘以稀释倍数;或用标准物的浓度与OD值计算出标准曲线的直线回归方程式,将样品的OD值代入方程式,计算出样品浓度,再乘以稀释倍数,即为样品的实际浓度。
注意事项
1.试剂盒从冷藏环境中取出应在室温平衡15-30分钟后方可使用,酶标包被板开封后如未用完,板条应装入密封袋中保存。
2.浓洗涤液可能会有结晶析出,稀释时可在水浴中加温助溶,洗涤时不影响结果。
3.各步加样均应使用加样器,并经常校对其准确性,以避免试验误差。一次加样时间最好控制在5分钟内,如标本数量多,推荐使用排枪加样。
4. 请每次测定的同时做标准曲线,最好做复孔。如标本中待测物质含量过高(样本OD值大于标准品孔第一孔的OD值),请先用样品稀释液稀释一定倍数(n倍)后再测定,计算时请最后乘以总稀释倍数(×n×5)。
5. 封板膜只限一次性使用,以避免交叉污染。
6.底物请避光保存。
7.严格按照说明书的操作进行,试验结果判定必须以酶标仪读数为准.
8.所有样品,洗涤液和各种废弃物都应按传染物处理。
9.本试剂不同批号组分不得混用。
10. 如与英文说明书有异,以英文说明书为准。
保存条件及有效期
1.试剂盒保存:;2-8℃。
2.有效期:6个月
|
Human Methyltestosterone
FOR RESEARCH USE ONLY
Assay range:2 nmol/L -48 nmol/L 96 determinations
Purpose
This kit allows for the determination of Methyltestosterone concentrations in Human serum, cell culture supernates and other biological fluids
Principle of the assay
The kit assay Human Methyltestosterone level in the sample,use Purified Human Methyltestosterone antibody to coat microtiter plate wells, make solid-phase antibody, then add Methyltestosterone to wells, Combined Methyltestosterone antibody which With HRP labeled,become antibody - antigen - enzyme-antibody complex, after washing Completely, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human Methyltestosterone in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Materials provided with the kit
1 | wash solution | 20ml×1bottle | 7 | Stopp Solution | 6ml×1 bottle |
2 | HRP-Conjugate reagent | 6ml×1 bottle | 8 | Standard( 96 nmol/L) | 0.5ml×1 bottle |
3 | Microelisa stripplate | 12well×8strips | 9 | Standard diluent | 1.5ml×1bottle |
4 | Sample diluent | 6ml×1 bottle | 10 | Instruction | 1 |
5 | Chromogen Solution A | 6ml×1 bottle | 11 | Closure plate membrane | 2 |
6 | Chromogen Solution B | 6ml×1 bottle | 12 | Sealed bags | 1 |
Specimen requirements
1. extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
Assay procedure
1. Dilute and add sample:Dilute Original density Standard as follow table:
48 nmol/L | 5 Standard | 150μl Original density Standard+150μl Standard diluent |
24 nmol/L | 4 Standard | 150μl 5 Standard+150μl Standard diluent |
12 nmol/L | 3 Standard | 150μl 4 Standard+150μl Standard diluent |
6 nmol/L | 2 Standard | 150μl 3 Standard +150μl Standard diluent |
3 nmol/L | 1 Standard | 150μl 2 Standard +150μl Standard diluent |
2.add sample:Set blank wells separately (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
5.washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme:Add HRP-Conjugate reagent 50μl to each well, except blank well.
7.incubate:Operation with 3.
8.washing:Operation with 5.
9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
11.assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
Steps description
Standard, Sample diluent |
Add Standard, Sample diluent, incubate for 30 min at 37℃. |
Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37℃. |
Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37℃. |
Add Stopp Solution |
Read absorbance at 450nm within 15 min |
calculate |
Calculate
Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.
Important notes
1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
4. if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.
6. The substrate evade the light preservation.
7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
8. All samples, washing buffer and each kind of reject should according to infective material process.
9. Do not mix reagents with those from other lots.
Storage and validity
1.Storage: 2-8℃.
2.validity: six months
杭州co2激光焊接机_yag激光焊接机153-9155-1283杭州co2激光焊接机_yag激光焊接机
公司介绍: 楚天工业激光设备有限公司成立于1985年,是一家规模大、产品种类多、市场网络健全的专业激光产品制造商。 楚天工业激光设备有限公司为全球客户提供全面的激光加工解决方案和相关配套服务,其主要产品有激光焊接机、激光切割机、激光打孔机、激光标刻机、激光划片机、激光溶覆机、激光热处理机、太阳能电池激光加工机、激光加工机器人等十个系列百余种各类激光加工设备和配套服务。激光补焊的应用 激光模具焊接机焊接材料非常广泛,括: 冷作高合金钢、热锻高合金钢、含镍工具钢、高级钢、铜合金、铍铜、高韧铝合金等金属材料。 激光模具焊接机;适用于如数码产品、手机、玩具、汽车、摩托车等模具制造和成型行业。通过模具的修补,可以将原来的模具重新充分利用,大大节约了生产成本和提高了。机型特点
*焊斑能量分布均匀,具有焊接特性所需要的最佳光斑;
*适应各种复杂焊缝,各种器件的点焊;
*采用进口聚光腔体,更具有耐腐蚀、耐高温、寿命更长久;
*具有24小时连续工作能力,整机工作性能稳定
应用范围
应用于光通信器件、医疗、电池、光纤耦合器、显像管电子枪、金属零件、精密零件、各种模具、汽车钢片等焊接行业。工作效率
• 相对于氩弧焊接等其它焊接方式,激光修补模具具有以下优点:
• 激光焊接点直径只有0.2mm~2.0mm;
• 选用1064nm波长激光,对人体无害;
• 受热范围内小,不会出现变形,不会出现气孔;可加工材料如,模具钢、不锈钢、铍铜及贵重金属等;
• 可修补裂痕、崩角、模边、及磨损了的密封边;
• 焊接过后可以磨削加工成光面;
• 可在极硬的材料上进行焊接(~HRC 60)。
杭州co2激光焊接机_yag激光焊接机 杭州co2激光焊接机_yag激光焊接机
产 品 说 明 | ||
|
低温恒温反应浴(槽)是我厂参照日本东京理化器械株式会社的同类产品改进制造的一种新型实验仪器。适用于科研、生物、物理、医药、化工等部门进行低温实验,可代替干冰和液氮做低温反应和相关设备提供低温条件,又可以作为低温水槽做运用粘度的测试,又可底部装磁力搅拌,分两段搅拌,使不锈钢槽内温度更均匀,智能控温精确等特点。低温恒温反应浴的技术参数:
规格型号 | 储液容积(L) | 空载调节范围(℃) | 温度波动度(℃) | 制冷量(w) | 环泵流量(l/min) | 实用开口径 |
DFY-4/5 | 4 | -5~98 | ±0.5 | 135-165 | 4 | 120×80 |
DFY-4/10 | 4 | -10~98 | ±0.5 | 152-170 | 4 | 120×220 |
DFY-5/10 | 5 | -10~98 | ±0.5 | 170-195 | 4 | φ190 |
DFY-5/20 | 5 | -20~98 | ±0.5 | 242-920 | 4 | φ190 |
DFY-5/40 | 5 | -40~98 | ±0.5 | 205-1230 | 4.5 | φ190 |
DFY-5/80 | 5 | -80~98 | ±0.5 | 230-1200 | 4.5 | φ190 |
DFY-10/25 | 10 | -25~98 | ±0.5 | 300-2300 | 4.5 | φ220 |
DFY-10/30 | 10 | -30~98 | ±0.5 | 200-2600 | 4.5 | φ220 |
DFY-10/40 | 10 | -40~98 | ±0.5 | 230-1070 | 4.5 | φ220 |
DFY-10/80 | 10 | -80~98 | ±0.5 | 380-2600 | 4.5 | φ220 |
DFY-20/40 | 20 | -40~98 | ±0.5 | 648-2440 | 4.5 | φ290 |
DFY-20/80 | 20 | -80~98 | ±0.5 | 600-2800 | 4.5 | φ290 |
DFY-5/100 | 5 | -100~室温 | ±0.5 | 90-1200 | 4.5 | φ190 |
DFY-5/120 | 5 | -120~室温 | ±0.5 | 75-1500 | 4.5 | φ190 |
DFY-10/100 | 10 | -100~室温 | ±0.5 | 90-1000 | 4.5 | φ220 |
DFY-10/120 | 10 | -120~室温 | ±0.5 | 95-1200 | 4.5 | φ220 |
DFY-20/120 | 20 | -120~室温 | ±0.5 | 100-1500 | 4.5 | φ290 |
YP 系列电子天平具有流畅新颖的外形设计,体现了对现代理念的追求。的设计,使称重的反应速度更快,定点更迅速。稳定性和抗干扰性高。 本公司开发的YP系列电子天平还可以根据用户的要求进行生产。具有强大的灵活性,野外操作的选择。
特点:
交直流两用,带水准仪,液晶背光显示,称量反应速度快,高稳定性。
功能:
具有单位转换(米制克拉、金盎司等)、稳定度、记忆功能、动物称重、全量程去皮等多种功能,操作更简便。
内置RS232C输出接口,可直接连接计算机、打印机等外部设备。
| | | |
| | | |
| | | |
| | | |
| | | |
深圳市埃塔电子设备有限公司提供专业SMT全自动生产线解决方案,我们专业代理三星贴片机,作为三星贴片机的重要合作伙伴,埃塔一直致力于为客户提供最佳的smt设备和服务,主要型号有SM411,SM421,SM321等设备,欢迎咨询.我们还提供松下贴片机,FUJI贴片机,三星贴片机,YAMAHA贴片机/JUKI贴片机,西门子贴片机,富士贴片机,雅马哈贴片机,无铅回流炉,回流炉,无铅波峰焊炉
胡梅13632709811
雅马哈YC8特点:可贴装最大尺寸达100mm×100mm、高达45mm的元件支持贴装重达1kg的元件,还具备压入元件的功能机身仅宽880mm的小型化设计,可最大限度地有效利用空间支持可装最多15张托盘的自动更换式托盘供给装置 ATS15支持SS型电动送料器与ZS型电动送料器
机型:YC8
对象基板:L50 x W50mm ~ L330 x W360mm (※1)
貼裟精度:
本公司评估用使用标准元件时绝对精度(μ+3σ) :±0.05 mm/QFP重复精度(3σ) : ±0.03 mm/QFP
贴装能力:
参考指标:2.5 秒/元件(以吸附~识别-贴装元件为1 个周期)
对象元件:4 x 4 mm -100 x 100 mm (※2)(超过45 x 45mm 的元件,一部分贴装时有条件限制。)最大元件高度45mm最大载荷1 kg
元件供给形态:部件晶种数料带盘:最多可装28 个(以8mm 宽换算时)托盘:最多可装15 张 料杆
电源规格:三相AC 200/208/220/240/380/400/416 V ±10% 50/60 Hz
供给气源:0.45 MPa 以上、清洁干燥状态
外形尺寸(突起部除外): L880×W1,440×H1,445 mm (主体)L880×W1,755×H1,500 mm (配备ATS15 时)
重量:约1,000 kg (主体)ATS15: 约120 kg