联 系 人:廖学通 手机:13689577187
电话: 传真:
商 务 QQ:1838736967 电子邮箱:13689577187@139.com
联系地址:广州市天河区燕岭路123号建设大厦1200室
A1A125 TMF15/400 FF A2B250 TMF125/1250 FF A1B125 TMF15/400 FF+RCD
A1A125 TMF16/400 FF A2B250 TMF150/1500 FF A1B125 TMF16/400 FF+RCD
A1A125 TMF20/400 FF A2B250 TMF160/1600 FF A1B125 TMF20/400 FF+RCD
A1A125 TMF25/400 FF A2B250 TMF175/1750 FF A1B125 TMF25/400 FF+RCD
A1A125 TMF30/400 FF A2B250 TMF200/2000 FF A1B125 TMF30/400 FF+RCD
A1A125 TMF32/400 FF A2B250 TMF225/2250 FF A1B125 TMF32/400 FF+RCD
A1A125 TMF40/400 FF A2B250 TMF250/2500 FF A1B125 TMF40/400 FF+RCD
A1A125 TMF50/500 FF A2C250 TMF125/1250 FF A1B125 TMF50/500 FF+RCD
A1A125 TMF60/600 FF A2C250 TMF150/1500 FF A1B125 TMF60/600 FF+RCD
A1A125 TMF63/630 FF A2C250 TMF160/1600 FF A1B125 TMF63/630 FF+RCD
A1A125 TMF70/700 FF A2C250 TMF175/1750 FF A1B125 TMF70/700 FF+RCD
A1A125 TMF80/800 FF A2C250 TMF200/2000 FF A1B125 TMF80/800 FF+RCD
A1A125 TMF90/900 FF A2C250 TMF225/2250 FF A1B125 TMF90/900 FF+RCD
A1A125 TMF100/1000 FF A2C250 TMF250/2500 FF A1B125 TMF100/1000 FF+RCD
A1A125 TMF125/1250 FF A2N250 TMF125/1250 FF A1B125 TMF125/1250 FF+RCD
A1B125 TMF15/400 FF A2N250 TMF150/1500 FF A1C125 TMF15/400 FF+RCD
A1B125 TMF16/400 FF A2N250 TMF160/1600 FF A1C125 TMF16/400 FF+RCD
A1B125 TMF20/400 FF A2N250 TMF175/1750 FF A1C125 TMF20/400 FF+RCD
A1B125 TMF25/400 FF A2N250 TMF200/2000 FF A1C125 TMF25/400 FF+RCD
A1B125 TMF30/400 FF A2N250 TMF225/2250 FF A1C125 TMF30/400 FF+RCD
A1B125 TMF32/400 FF A2N250 TMF250/2500 FF A1C125 TMF32/400 FF+RCD
A1B125 TMF40/400 FF A3N400 TMF320/3200 FF A1C125 TMF40/400 FF+RCD
A1B125 TMF50/500 FF A3N400 TMF400/4000 FF A1C125 TMF50/500 FF+RCD
A1B125 TMF60/600 FF A3N630 TMF500/5000 FF A1C125 TMF60/600 FF+RCD
A1B125 TMF63/630 FF A3N630 ELT-LI R630 FF A1C125 TMF63/630 FF+RCD
A1B125 TMF70/700 FF A3S400 TMF320/3200 FF A1C125 TMF70/700 FF+RCD
A1B125 TMF80/800 FF A3S400 TMF400/4000 FF A1C125 TMF80/800 FF+RCD
A1B125 TMF90/900 FF A3S630 TMF500/5000 FF A1C125 TMF90/900 FF+RCD
A1B125 TMF100/1000 FF A3S630 ELT-LI R630 FF A1C125 TMF100/1000 FF+RCD
A1B125 TMF125/1250 FF A2B250 TMF125/1250 FF+RCD A1C125 TMF125/1250 FF+RCD
A1C125 TMF15/400 FF A2B250 TMF150/1500 FF+RCD A1N125 TMF15/400 FF+RCD
A1C125 TMF16/400 FF A2B250 TMF160/1600 FF+RCD A1N125 TMF16/400 FF+RCD
A1C125 TMF20/400 FF A2B250 TMF175/1750 FF+RCD A1N125 TMF20/400 FF+RCD
A1C125 TMF25/400 FF A2B250 TMF200/2000 FF+RCD A1N125 TMF25/400 FF+RCD
A1C125 TMF30/400 FF A2B250 TMF225/2250 FF+RCD A1N125TMF30/400 FF+RCD
A1C125 TMF32/400 FF A2B250 TMF250/2500 FF+RCD A1N125 TMF32/400 FF+RCD
A1C125 TMF40/400 FF A2C250 TMF125/1250 FF+RCD A1N125 TMF40/400 FF+RCD
A1C125 TMF50/500 FF A2C250 TMF150/1500 FF+RCD A1N125 TMF50/500 FF+RCD
A1C125 TMF60/600 FF A2C250 TMF160/1600 FF+RCD A1N125 TMF60/600 FF+RCD
A1C125 TMF63/630 FF A2C250 TMF175/1750 FF+RCD A1N125 TMF63/630 FF+RCD
A1C125 TMF70/700 FF A2C250 TMF200/2000 FF+RCD A1N125 TMF70/700 FF+RCD
A1C125 TMF80/800 FF A2C250 TMF225/2250 FF+RCD A1N125 TMF80/800 FF+RCD
A1C125 TMF90/900 FF A2C250 TMF250/2500 FF+RCD A1N125 TMF90/900 FF+RCD
A1C125 TMF100/1000 FF A2N250 TMF125/1250 FF+RCD A1N125 TMF100/1000 FF+RCD
A1C125 TMF125/1250 FF A2N250 TMF150/1500 FF+RCD A1N125 TMF125/1250 FF+RCD
A1N125 TMF15/400 FF A2N250 TMF160/1600 FF+RCD A3N400 TMF320/3200 FF+RCD
A1N125 TMF16/400 FF A2N250 TMF175/1750 FF+RCD A3N400 TMF400/4000 FF+RCD
A1N125 TMF20/400 FF A2N250 TMF200/2000 FF+RCD A3N630 TMF500/5000 FF+RCD
A1N125 TMF25/400 FF A2N250 TMF225/2250 FF+RCD A3N630 ELT-LI R630 FF+RCD
A1N125 TMF30/400 FF A2N250 TMF250/2500 FF+RCD A3S400 TMF320/3200 FF+RCD
A1N125 TMF32/400 FF A3S400 TMF400/4000 FF+RCD
A1N125 TMF40/400 FF A3S630 TMF500/5000 FF+RCD
A1N125 TMF50/500 FF A3S630 ELT-LI R630 FF+RCD
A1N125 TMF60/600 FF
A1N125 TMF63/630 FF
A1N125 TMF70/700 FF
A1N125 TMF80/800 FF
A1N125 TMF90/900 FF
A1N125 TMF100/1000 FF
A1N125 TMF125/1250 FF
|
核心提示:上面是“便携式心电监护仪 迈瑞MEC-1000 多参数监护仪”的详细介绍,您可以在这里联系便携式心电监护仪 迈瑞MEC-1000 多参数监护仪的卖家,更详细地了解心电监护仪的规格、型号、价格及其他一切信息……
产品型号 | JLT-2 | JLT-2 | JLT-2 | JLT-2 | JLT-2 | JLT-21 |
输入范围 | 5A…50A | 5A…50A | 5A…50A | 5A…50A | 5A…50A | 5A…50A |
输出规格 | 0…3.5V / 0…5V | 0…5V / 0…10V | 0…5V / 0…10V | 0…20mA /4…20mA | 0…5V | 0…20mA/4…20mA |
输出特性 | 跟踪电压 | 平均电压 | 平均电压 | 平均电流 | 真电压 | 真电流 |
精度等级 | < 0.1 % | < 0.2 % | < 0.5 % | < 0.5 % | < 0.2 % | < 0.2 % |
负载能力 | 5mA | 5mA | 5mA | 6V | 5mA | 6V |
响应时间 | < 15μs | < 300ms | < 300ms | < 300ms | < 300ms | < 300ms |
温度漂移 | 50ppm/℃ | 150ppm/℃ | 150ppm/℃ | 350ppm/℃ | 50ppm/℃ | 50ppm/℃ |
供电电源 | ±12Vdc(±15Vdc) | +12Vdc(+24Vdc) | +12Vdc(+24Vdc) 三隔离 | +12Vdc(+24Vdc) | +12Vdc(+24Vdc) | +12Vdc(+24Vdc) |
静态功耗 | 5mA | 3mA | 13 mA | 3.3mA/6.8mA | 21 mA | 21 mA /25 mA |
安装 | 采用5mmDIN卡轨装,也可以用M3镙栓将传感器固定在任何平面上 | 采用35mmDIN卡轨装,也可以用M3镙栓将传感器固定在任何平面上 | 采用35mmDIN卡轨装,也可以用M3镙栓将传感器固定在任何平面上 | 采用35mmDIN卡轨装,也可以用M3镙栓将传感器固定在任何平面上 | 采用35mmDIN卡轨装,也可以用M3镙栓将传感器固定在任何平面上 | 采用35mmDIN卡轨装,也可以用M3镙栓将传感器固定在任何平面上 |
备注 | 更多型号请来电咨询 |
泵的主要性能参数泵的性能参数主要有流量和扬程,此外还有轴功率、转速和必需汽蚀裕量。流量是指单位时间内通过泵出口输出的液体量,一般采用体积流量;扬程是单位重量输送液体从泵入口至出口的能量增量 ,对于容积式泵,能量增量主要体现在压力能增加上,所以通常以压力增量代替扬程来表示。泵的效率不是一个独立性能参数,它可以由别的性能参数例如流量、扬程和轴功率按公式计算求得。反之,已知流量、扬程和效率,也可求出轴功率。泵的各个性能参数之间存在着一定的相互依赖变化关系,可以通过对泵进行试验,分别测得和算出参数值,并画成曲线来表示,这些曲线称为泵的特性曲线。每一台泵都有特定的特性曲线,由泵制造厂提供。通常在工厂给出的特性曲线上还标明推荐使用的性能区段,称为该泵的工作范围。泵的实际工作点由泵的曲线与泵的装置特性曲线的交点来确定。选择和使用泵,应使泵的工作点落在工作范围内,以保证运转经济性和安全。此外,同一台泵输送粘度不同的液体时,其特性曲线也会改变。通常,泵制造厂所给的特性曲线大多是指输送清洁冷水时的特性曲线。对于动力式泵,随着液体粘度增大,扬程和效率降低,轴功率增大,所以工业上有时将粘度大的液体加热使粘性变小,以提高输送效率。
我们将不断完善自我,精益求精,把客户的意见作为我们改进的方向,把客户的肯定作为我们发展的动力。追求每一件产品的质量,每一次服务的效率。我们的目标就是通过不断提高产品质量以及我们的服务水平来满足客户最大的需求。以良好的信誉挚诚的服务报答广大客户的厚爱。
上海鸿蝶阀门有限公司专业生产销售【Q41N-160P高压法兰球阀】,欢迎来电咨询【Q41N-160P高压法兰球阀】的价格和详细信息,好【Q41N-160P高压法兰球阀】,上海鸿蝶阀门有限公司造!
高压法兰球阀的驱动方式可选用手动、蜗轮、气动、电动,高压法兰球阀的连接方式可选用法兰、焊接,高压法兰球阀的结构形式可选用三通式,高压法兰球阀的密封结构可选用软密封、硬密封,高压法兰球阀的压力范围PN1.0-32.0Mpa,高压法兰球阀的公称通径为DN10-200mm,高压法兰球阀的材质可选用锻钢、锻不锈钢。
零件名称 | 材质 | |
GB | ASTM | |
阀体、阀盖 | WCB | A216-WCB |
密封圈 | 尼龙 | 尼龙 |
球体 | 1Cr18Ni9Ti | SS 304 |
阀座、阀杆 | 2Cr13 | A246-416 |
O形圈 | 橡胶 | 橡胶 |
双头螺栓 | 35CrMoA | A193-B7 |
公称压力PN | 16 | 32 | MPa |
强度试验压力PT | 24 | 48 | MPa |
低压密封试验力 | 0.6 | MPa | |
高压密封试验力 | 17.6 | 35.2 | MPa |
适用介质 | 水、油品、蒸汽 | ||
适用温度 | -40~80℃ |
公称 压力 | 公称 通径 | 主要尺寸 | ||||||||||||||
L | L1 | D | D1 | H | W | M | D2 | b | Z-Φd | |||||||
法兰 | 对焊 | 法兰 | 对焊 | 法兰 | 对焊 | 法兰 | 对焊 | 法兰 | 对焊 | 法兰 | ||||||
16.0 | 10 | 210 | 150 | 52 | 60 | 95 | 90 | 60 | 18 | 77 | 58 | 220 | M24×2 | 18 | 20 | 3-18 |
15 | 230 | 170 | 62 | 70 | 95 | 100 | 60 | 23 | 85 | 62 | 220 | M24×2 | 20 | 20 | 3-18 | |
20 | 240 | 190 | 73 | 80 | 105 | 110 | 68 | 29 | 94 | 75 | 250 | M33×2 | 28 | 20 | 3-18 | |
25 | 260 | 205 | 77 | 95 | 105 | 115 | 68 | 36 | 100 | 80 | 250 | M33×2 | 28 | 22 | 3-18 | |
32 | 300 | 230 | 100 | 110 | 115 | 150 | 80 | 43 | 120 | 96 | 300 | M42×2 | 38 | 24 | 4-18 | |
40 | | 260 | 110 | 120 | 165 | 170 | 115 | 49 | 150 | 111 | 400 | M52×2 | 48 | 30 | 6-26 | |
50 | 400 | 330 | 130 | 140 | 165 | 200 | 115 | 61 | 165 | 128 | 450 | M64×3 | 58 | 32 | 6-26 | |
65 | 490 | 360 | 140 | 150 | 200 | 225 | 145 | 80 | 180 | 180 | 500 | M80×3 | 74 | 40 | 6-29 | |
80 | 580 | 380 | 150 | 160 | 225 | 270 | 170 | 105 | 200 | 200 | 600 | M100×3 | 94 | 50 | 6-33 | |
100 | 620 | 430 | 178 | 188 | 260 | 320 | 195 | 118 | 245 | 245 | 800 | M125×4 | 115 | 60 | 6-36 | |
32.0 | 10 | 210 | 150 | 52 | 60 | 95 | 90 | 60 | 18 | 77 | 58 | 220 | M24×2 | 18 | 20 | 3-18 |
15 | 230 | 170 | 62 | 70 | 105 | 100 | 68 | 23 | 85 | 62 | 220 | M33×2 | 28 | 20 | 3-18 | |
20 | 240 | 190 | 73 | 80 | 105 | 110 | 68 | 29 | 94 | 75 | 250 | M33×2 | 28 | 20 | 3-18 | |
25 | 260 | 205 | 77 | 95 | 115 | 115 | 80 | 36 | 100 | 80 | 250 | M42×2 | 35 | 25 | 4-18 | |
32 | 300 | 230 | 100 | 110 | 165 | 150 | 115 | 43 | 120 | 96 | 300 | M52×2 | 41 | 30 | 4-22 | |
40 | 350 | 260 | 110 | 120 | 165 | 170 | 115 | 49 | 150 | 111 | 400 | M64×3 | 47 | 35 | 6-26 | |
50 | 400 | 330 | 130 | 140 | 200 | 200 | 145 | 61 | 165 | 128 | 450 | M80×3 | 70 | 40 | 6-29 | |
65 | 490 | 360 | 140 | 150 | 225 | 225 | 170 | 80 | 180 | 180 | 500 | M100×3 | 90 | 50 | 6-33 | |
80 | 580 | 380 | 150 | 160 | 260 | 270 | 195 | 105 | 200 | 200 | 600 | M125×4 | 112 | 55 | 6-36 | |
100 | 620 | 430 | 178 | 188 | 300 | 320 | 235 | 118 | 245 | 245 | 800 | M155×4 | 135 | 65 | 8-36 |
YSD-1 微机控制电液伺服岩石三轴试验机适用的试验方法标准 SL264-2001《水利水电工程岩石试验规程》。依据国标等相关标准研制,在行业内注重实际,操作简单,数据确为原则。
YSD-1 微机控制电液伺服岩石三轴试验机主要特点:
YSD-1 微机控制电液伺服岩石三轴试验机主要由高刚度(中刚度)主机、压力自平衡式三轴压力室、增压器、伺服液压源、伺服阀、空气压缩机组、测控系统、计算机系统等部分组成。
1. 高刚度主机主机为门型框架式高刚度结构。工作油缸放置在框架的下横梁中部,两侧配置轨道,方便三轴压力室安装和拆卸。框架上横梁中部安装球面压板,可自动调心,使压板与压缩杆端部紧密接触。
2. 压力自平衡式三轴压力室压力室采用压力自平衡技术,使轴向试验力与围压互不干涉,相互独立。采用高强度合金结构钢制成,各压盘及传压活塞杆采用轴承钢经过热处理及密加工而成。压力室放置在移动小车上,可沿轨道移动,装卸试样方便。
3. 增压器是将系统的工作油液经过压力放大后而输出的超高压油源,超高压油液供给三轴压力室。做为侧向压力(即围压)。
4. 伺服液压源伺服液压源由高压柱塞泵组、溢流阀、密滤油器、温度传感器、冷却器等组成的伺服油路系统及低压齿轮泵所组成的注油充液系统和围压增压系统三部分组合而成。试验用油与伺服用工作油相互分开,互不污染,提高了使用寿命。
5. 空气压缩机组是用来排除压力室内腔油液而设置的。
6. 微机控制电液伺服岩石三轴剪切试验系统测控系统测量控制系统由轴向力传感器、围压传感器、轴向变形传感器、径向变形传感器、位移传感器、数字式测控器、伺服阀等部分组成。
6.1 设有12个测量通道,其中力2个通道;轴向及径向变形各1个通道;位移2个通道。
6.2 测量分辨力高,在程范围内部变化,内外不分档。
6.3 具有自动清零、标定、自动存储功能。
6.4 具有恒试验力、恒变形、恒位移、匀试验力速率、匀变形速率控制功能。
6.5 具有超载、超量程、油路堵塞、超油温、试件断裂等保护功能。
YSD-1 微机控制电液伺服岩石三轴试验机系统标准配置:
1. 刚性主机 一台(主机结构及刚度根据用户要求)
2. 压力自平衡式三轴压力室 一台
3. 增压器 一套
4. 伺服液压源 一台
5. 数字伺服控制器 一台
6. 空气压缩机组 一台
技术参数:
1、主机刚度达5GN/m以上
2、轴向最大试验力1000kN,测力分辨率10N,测力度±1%。
3、最大围压60Mpa,围压测控度±2%,围压分辨率0.1MPa。
4、、变形测控范围:轴向0-5mm 径向0-3mm 测量分辨率0.0001mm 测量度±1%
5、位移测控范围: 0-100mm 测量度<±0.5%FS 测量分辨率高于万分之一
6、控制波形:用户根据需要可任意设定包含有加载、保载、卸载环节的多种程序波形(自编程序);加卸载和保载时间设置范围0~30小时。
7、极限控制:当轴向变形、径向变形、时间等参数达到极限值或预设置、试样断裂、油路堵塞和油温过高时均可自动保护。
8、空间高度:350mm,宽度:400mm(完可以放置下巴西劈裂夹具,三轴室)
9、试样规格: Φ75X150mm。
※ 采用模块化的24位AD温度采集电路,保证了万分之一位的测温精确性。
※ 测温模块采用超低温漂特性电子元件,保证了测试结果的稳定性。
※ 以嵌入式ARM为主控芯片,配置9寸真彩触摸液晶屏以及鼠标设备,实现了操作更简单、灵活;直接的人机交互方式,使用更方便。
※ 具备了计算机强大的数据处理功能和极强的可扩展能力,实现了对仪器的完美表达。历史数据的查询、打印变得简单轻松,并为今后的设备组网和数据共享提供了兼容的可能。
※ 具有以往“个人计算机+控制器”模式的相同数据处理速度,增强了可靠性。
实时的冷却校正,对环境温度要求宽松。硫,氢,水数据可在实验完成后补充输入并自动换算高、低位发热量,更符合常规实验过程。
※ 注水、排水、搅拌、点火、采温、计算、校正、打印的实验过程全自动,避免了人为误差,准确度及精密度大大提高。
※ 显示平台采用大尺寸彩色液晶触摸屏显示器,显示信息量非常丰富、直观、清晰,支持文件或文档的查阅。可查看煤炭试验方法国家标准要求、实验方法和实验步骤等。
※ 设备一体化设计外形,安装、更换方便,性能更可靠。
测温范围:5-40℃
温度分辨率:0.0001K
氧弹容积:300ml
内筒容积:2000ml
济南博涵生物科技有限公司是一家以研发,生产,销售于一体的生产型公司,为广大科研机构、高等院校、环保、食品、医疗、化工等领域的客户提供最好的产品及技术服务。公司现阶段涉及主要产品有:生物安全柜、超净工作台、通风柜等空气净化仪器;离心机、培养箱、摇床等实验室常规设备;显微镜、光度计、色谱仪等实验室光学设备;酶标仪、移液器等实验室分子生物仪器;环境监测、土壤监测等实验室分析测试仪器、生化分析仪、血球仪、尿液分析仪等医用医疗器械等等。
单人半排二级A2生物安全柜BSC-1100IIA2
生物安全柜技术参数1、等级:II级A2型,30%外排 (1).外部尺寸(L×D×H) 1100mm ×850mm×2200mm, (2).内部尺寸(L×D×H) 900mm ×600mm×660mm 2、符合中国SFOA的YY0569标准和美国NSF/ANSI 49标准中二级生物安全柜分类为A2型的要求。3、垂直层流负压机型。30%的空气经过滤后向室外排出或接到排风系统。4、工作区与外部环境形成气幕及箱体双层隔离,同时工作区被负压包围,保证产品不发生泄漏。5、工作区全部采用SUS304不锈钢,圆弧角内胆一次成型增加自洁功能。箱体部分采用1.5mm厚的冷轧钢板且表面静电喷涂。支架由金属组成,表面静电喷涂。6、配置大于4升的SUS3O4全不锈钢集液槽。7、滑动前窗采用日本进口的悬挂升降系统,使用大千5mm厚的安全玻璃能任意升降定位、性能可靠、免维护。关闭密封后便于灭菌处理。8、VFD液晶显示画面亮度均匀一致。液晶屏实时显示下降风速、吸入风速、过滤器使用寿命和堵塞报警、风机运行状况和故障报警、实时监测与显示机组运行时间等参数。9、遥控控制,采用日本NEC遥控器专用芯片,可以在距生物安全柜前6米、30°的范围内灵活控制生物安全柜的全部功能,使用者可以随身携带操作。10、有的预约定时功能:能够在杀菌消毒后自动开机或关机。预约开机运行或紫外消毒功能。11、轻触按键操作。12、前窗开启高度限位声光报警系统与照明控制联动。13、照明和杀菌系统的安全互锁系统。14、设有脚踏开关控制玻璃门升降,便于操作者在双手不方便的情况下通过控制脚踏开关,在玻璃门的活动范围之内,能灵活的控制玻璃门的上下运动。15、进口的风机智能风量自动补偿系统,确保在过滤器阻力增加50%的情况下风机风量变化小于10%。提离安全性。16、严格的拒体防泄漏检测,确保柜体在500Pa的条件下无任何泄漏。17、严格的HEPA/ULPA过滤器防泄漏检测,确保可扫描过滤器漏过率≤0.01%,不可扫描过滤器漏过率≤0.005%。18、洁净等级:ISO 5级(100级) ISO 4(10级)19、过滤器级别/过滤效率:
HEPA/ULPA@0.3~0.12μm 99.995%~99.999%20、振动半峰值:≤3μm21、人员防护:a.撞击式采样器的菌落总数≤10CFU/每次,b.狭缝式采样器菌落总数≤5CFU/每次22、受试产品防护:菌落总数≤5CFU/每次23、交叉感染防护:菌落总数≤2CFU/每次
生物安全柜工作环境仅适用于室内;环境温度:15℃~35℃;相对湿度:≤75%;大气压力范围:70kPa~106kPa;电源:AC 220V±10%, 50Hz;功率:≤1200W。生物安全柜操作说明1、减少键(-)调整十分位(右边第二个),按确认键(confirm)确认。同样的方法设定小时位(右边第三个)和10小时位(左边第一个)。每次预约都要按4次确认键(confirm)。2、时间确认后,通过功能键(遥控器上都有)选定功能,相应的功能指示灯亮。3、按电源键(power)启动预约功能。这时,预约时间开始倒计时,当预约时间到了以后,对应的功能启动。4、定时关机: (1).按下定时键(Install Timer),再通过调大(+)、调小键(-)、确认键(Confirm)确定时间的分位(与预约开机相同),按确认键(Confirm)确认,接着再通过增大(+)、减少键(-)调整十分位,按确认键( Confirm)确认。同样的方法设定小时的个位和小时的十位(方法如同预约)。 (2).当第4次按下确认键(Confirm)后,即确认时间最高位后,定时开始,时间开始倒计时,当时间到后,关闭所有功能,设备处于待机状态。5、在正常使用过程中,照明(LIGHT)、插座(SOCKET)、风机(WM)、消毒(KG)按键一次启动相应功能,再按一次则取消启动该功能。6、保养与维护 (1).安全柜应定期进行清洁消毒,柜内台面污染物可在工作完成且紫外灯消毒后用2%的84消毒液擦拭。柜体外表面则可以每天用1%的84消毒液擦拭。 (2).安全柜的内表面应在每次使用前与使用后进行去污处理。要用消毒剂擦拭工作台表面及内壁面,使用的消毒剂应能杀死柜内可能存在的所有微生物。一天工作结束时,应进行最后表面去污处理,即对工作台、各个侧面、背面及玻璃的里面进行全面擦拭。可以使用或70%酒精,这种对目标生物有效的消毒剂。如使用这种有腐蚀性的消毒剂,则要用灭菌水进行二次擦拭。建议工作柜在清洁、消毒时处在工作状态。如果其未处在工作状态,则应运行5分钟,以便在安全柜关闭前将其中的气体清除掉。 (3).生物安全柜使用一年后应通知制造商对设备整体维护一次,把包括对过滤器的消毒处理,并对维护结果记录。生物安全柜注意事项1.生物安全柜在安装搬运过程中,竖直搬运,到搬入安装现场后拆开包装。2.生物安全柜安装位置避开人流频繁处,并避免房间气流对操作口空气幕的干扰。3.安全柜不安装在房间通风系统的进口,以免气流直接吹到安全柜。4.正面的操作口和排风过滤器上。安全柜的周围留出30cm的空间,以便于清除脏物.如果由于空间限制,至少在两边留出25cm,背面留出30cm。5.在安全柜的电源处留出足够的空间(注意漏电保护措施),以便于在不移动安全柜的情况下,就可以进行维修。6.安装的生物安全柜底面和底边紧贴地面的安全柜,所有沿地边的缝隙加以密封。7.生物安全柜的排风管道的连接方式,以更换排风过滤器方便来确定。8.如果需要在安全柜内使用其他气体时,同时安装气源气路,安装压力表和阀门并且注意选择适用不同气体的管道材料。9.验收标准:按照产品原始样本技术数据及技术标书响应数据进行验收。
杭州生物安全柜价格,上海生物安全柜厂家直销,天津生物安全柜型号
北京生物安全柜打折,重庆生物安全柜报价,河北生物安全柜厂家
石家庄生物安全柜用途,辽宁生物安全柜规格,沈阳生物安全柜使用方法
【名称】三七皂苷R1
【别名】
【英文名】Notoginsenoside R1
【分子式】C47H80O18
【分子量】933.131
【CAS号】80418-24-2
【检测方式】高效液相色谱法HPLC≥98%
【规格】可根据客户需求包装
【性状】 white powder
【作用与用途】
【提取来源】三七Panax notoginseng( Burk.)F.H.Chen的干燥根及根茎