指标 | 余氯 | 氨氮 | 二氧化氯 | 溶解氧 | 亚硝酸盐 | 铜 | 铁 | 铬 | 锰 | 镍 |
测量范围 | 0-2.5 0-10 | 0-10 | 0-5 | 0-12 | 0-0.3 | 0-2.0 | 0-0.8 0-10 | 0-0.5 | 0-0.5 0-5 | 0-2.0 |
最小示值 | 0.001mg/L | |||||||||
重复性 | ≤2% | |||||||||
线性误差 | ±(5%FS+1个字)
| |||||||||
供电电源 | AC220V/50Hz;DC9V/0.2A | |||||||||
特点 净重 | 便携台式、交直流二用、稳定性好 500g |
酸度(pH)、氧化还原电位(ORP)、温度技术指标 | |||||
pH | 量程 | -2.0 to 20.0;-2.00 to 20.00;-2.000 to 20.000 pH | |||
解析度 | 0.1;0.01;0.001 pH | ||||
精度 | ±0.01;±0.002 pH | ||||
氧化还原电位 mV | 量程 | ±2000 mV | |||
解析度 | 0.1 mV | ||||
精度 | ±0.2 mV | ||||
温度 | 量程 | -20.0 to 120.0 °C (-4.0 to 248.0°F) | |||
解析度 | 0.1°C (0.1°F) | ||||
精度 | ±0.4°C (±0.8°F) | ||||
电导率,电阻率,TDS,盐度技术指标 | |||||
电导率 | 量程 | 0 to 400mS/cm (实际电导率1000 mS/cm)自动选择量程 0.001 to 9.999 μS/cm;10.00 to 99.99 μS/cm;100.0 to 999.9 μS/cm; 0.000 to 9.999 mS/cm;10.00 to 99.99 mS/cm;100.0 to 1000.0 mS/cm | |||
解析度 | 0.001 μS/cm;0.01 μS/cm;0.1 μS/cm;0.001 mS/cm;0.01 mS/cm;0.1 mS/cm | ||||
精度 | 读数的±1% (±0.01 μS/cm 或1个字,较大者) | ||||
电阻率 | 量程 | 1 to 999.9 Ohm•cm;1.000 to 9.999 kOhm•cm;10.00 to 99.99 kOhm•cm;100.0 to 999.9 kOhm•cm;1.0 to 100.0 MOhm•cm 自动选择量程 | |||
解析度 | 0.1 Ohm•cm; 0.001 kOhm•cm;0.01 kOhm•cm;0.1 kOhm•cm; 0.1 MOhm•cm | ||||
精度 | 读数的±2% (±1 Ohm•cm或1个字, 较大者) | ||||
TDS | 量程 | 0.00 to 99.99 ppm;100.0 to 999.9 ppm;1.000 to 9.999 g/L;10.00 to 99.99 g/L;100.0 to 400.0 g/L自动选择量程 | |||
解析度 | 0.01 ppm;0.1 ppm;0.001 g/L;0.01 g/L;0.1 g/L | ||||
精度 | 读数的±1% (±0.05 ppm或1个字,较大者) | ||||
盐度 | 量程 | 百分比盐度:0.0 to 400.0%;海水盐度:0.00 to 80.00(PSU);实际盐度:0.01 to 42.00 | |||
解析度 | 0.1%;0.01 | ||||
精度 | 读数的±1% | ||||
溶解氧、压强技术指标 | |||||
溶解氧 | 量程 | 0.00 to 50.00 ppm;0.0 to 600.0 % | |||
解析度 | 0.01 ppm;0.1% | ||||
精度 | 0 to 300%:读数的±1.5%或±1.0%,取较大者;300 to 600%:读数的±3%;0 to 30 mg/L:读数的±1.5%或0.10 mg/L,30 mg/L to 50 mg/L:读数的±3% | ||||
压强 | 量程 | 450 to 850 mmHg | |||
解析度 | 1 mm Hg | ||||
精度 | ± 3 mmHg (温度距校准点温度±15°C) | ||||
其他参数 | |||||
数据接口 | USB数据接口(选购HI92000软件及对应数据线) | ||||
配套电池 | 电池组 | ||||
自动关机 | 用户选择:5,10,30,60分钟后关机或者不关机 | ||||
其他功能 | 具有防水功能,IP67 |
测量参数 | 电导率 | 温度 | pH值, ORP |
范围 | 0~1999.9 mS/cm 0 ~ 200g/l KCl 0~ 250g/l NaCl | -50~199.9 °C | -2~16 pH ±1000 mV |
精度 (±1 digit) | 0.10% >20 mS/cm 0.25 % | ±0.1 °C | ±0.002 pH ±0.1 mV |
温度补偿 | -5~70 °C | - | -5~110.0 °C |
K系数范围 | 0.01~19.999 cm-1 | - | - |
Α系数 | 0~10%/°C | | |
输入阻抗 | - | - | 1012 W |
温度探头 | Pt-1000 标准型或精确型 | ||
尺寸(mm) | L = 149, W = 82, H = 22 | ||
重量 | CC-401 220 g CPC-401 229 g | ||
* 温度测量的总误差取决于探头类型。 |
辽宁沈阳便携式多参数水质检测仪产品资料:
工作原理:本仪表应用全中文微电脑比例式检测,光电子比色检测离子。消除了人为误差,因此测量分辨率大大提高。
参数规格:
余氯、化合氯:0-2.5mg/L,0.01mg/L
总氯:0-10mg/L,0.01mg/L
DPD余氯:0-2.5mg/L,0.01mg/L
DPD总氯:0-2.5mg/L,0.01mg/L
低浊度:0-20NTU,0.01NTU
高浊度:0-1000NTU,0.1NTU
二氧化氯:0-2.0mg/L,0.01mg/L
氨氮:0-10mg/L,0.01mg/L
悬浮物:0-200mg/L,0.01mg/L
铜:0-2.0mg/L,0.01mg/L
溶解氧:0-12mg/L,0.01mg/L
磷酸盐:0-2.0mg/L,0.01mg/L
亚硝酸盐:0-0.3mg/L,0.01mg/L
铬:0-0.5mg/L,0.01mg/L
锰:0-0.5mg/L,0.01mg/L
铁:0-0.8mg/L,0.01mg/L
镍:0-1.0mg/L,0.01mg/L
色度:0-100PCU,0.01PCU
高色度:0-500PCU,0.01PCU
安装步骤与维护:选配件
大功率电池 (可携带至现场检测)
热敏打印机 (打印即时测试数据)
辽宁沈阳便携式多参数水质检测仪产品特点:
1.微电脑,轻触式键盘,全中文菜单,采用背光高亮度LCD显示数值,操作和标定过程全中文提示,使用方便。
2.可自动调零和5点自动校正,量程有自动和手动切换,并且有数据非线性处理及数据平滑功能。
3.本仪器采用特制高强度长寿命光源,独特的专利恒光源半导体发光器使其光源恒稳定,而且光源寿命长达20年,开机时无需预热,可直接使用。
4.本仪器还具有选择离子测量功能,其光源自动切换,适用于水中20项常见指标的快速定量测定。
5.主机内可选配大功率电池,既可用于实验室也可用于野外现场定量测量,充电4小时可连续使用4小时,即充即用。
6.采用矩形光学玻璃比色皿,表面平整光洁,克服了圆管比色皿管壁厚薄不均匀造成每次测量的误差,重复性好,测定时更精确。
7.本仪器融合多项自主设计专利成果,技术,符合国标GB/T5750-2006生活饮用水卫生标准。
咨询电话 谢经理 18910282272便携式多参数水质检测仪
型号:SZ55/CX-401 库号:M326939
* 能测量pH值、电导率、TDS、氧化还原电位、溶解氧、大气压力及温度。 * 大屏幕LCD显示,读数更清晰。* 电源模式,能用9V电池或12V电源适配器,能在室内或长时间在户外工作。*测量仪性能: - 在测量范围内能测量pH值(精度0.002 pH )。- 能精确测量ORP(精度0.1mV)。- 能测量纯水或高盐度水。- 在测量盐度时(NaCl或KCl),能自动修正电导率对盐度的影响。
- 能测量TDS。- 测量电导率时可改变参考温度。- 能测量大气压。- 测量溶解氧时,能自动修正大气压和盐度的影响,从而使测量工作极其简单。- 温度测量范围宽。- 能储存950组连续或独立的测试结果,附温度、时间和日期。- 具R-232、USB接口* 所有功能操作简便、快捷。* 质量期:18个月。技术指标:测量参数 电导率 温度 pH值, ORP 范围 0~1999.9 mS/cm -50~199.9 °C -2~16 pH 0 ~ 200g/l KCl ±1000 mV 0~ 250g/l NaCl 精度 (±1 digit) 0.10% ±0.1 °C ±0.002 pH >20 mS/cm 0.25 % ±0.1 mV 温度补偿 -5~70 °C - -5~110.0 °C K系数范围 0.01~19.999 cm-1 - - Α系数 0~10%/°C 输入阻抗 - - 1012 W 温度探头 Pt-1000 标准型或精确型 尺寸(mm) L = 149, W = 82, H = 22 重量 CC-401 220 g CPC-401 229 g * 温度测量的总误差取决于探头类型。