概述 Overview
ASJ50-GQ 空调压缩机电压监控装置(以下简称监控装置),适用于单相交流电压220V、频率 50Hz/60Hz 的用户或负载。当线路发生过、欠电压时,监控装置对设备进行保护。监控装置集线路过电压、欠电压保护功能和线路正常电压自动延时复位功能。产品产品体积小、精度高、结构 紧凑、安装方便。
ASJ50-GQ air conditioning compressor voltage monitoring device (hereinafter referred to as the monitoring device), suitable for single phase AC voltage 220V, frequency 50Hz/60Hz users or load. When the line is over and under voltage, the monitoring device protects the equipment. Line monitoring device over-voltage and under voltage protection function and normal line voltage delay automatic reset function. The product is small in size, high in precision, compact in structure and convenient in installation.
引用标准Reference standard
GB/T 14598.127-2013 量度继电器和保护装置第127部分过/欠电压保护功能要求
GB/T 14598.127-2013 measure relay and protective device 127th part over-voltage protection functional requirements
产品特点Product features
■ 内置高性能处理器,高可靠性,抗干扰能力强。
■ Built in high performance processor, high reliability and strong anti-interference ability.
■ 线路发生过电压、欠电压时切断线路,线路电压恢复正常经延时后自动复位接通线路,无需人工操作。
■ The line is cut off when overvoltage and undervoltage occur, and the line voltage is restored to the line automatically after the delay, and no manual operation is needed.
■ 频率 50Hz/60Hz 通用,产品功耗不大于 2VA。
■ The frequency 50Hz/60Hz is universal, and the power consumption is not more than 2VA.
■ 电气寿命:10000 次。
■ Electrical life: 10000 times.
■ 孔径安装。
■ Aperture installation.
主要参数main parameter
表 1 技术参数Table 1 technical parameters
外形结构Shape structure
监控装置产品外形结构及尺寸如图 1 所示。The configuration and size of the monitoring device is shown in Figure 1.
操作指南Operation guide
操作说明Operation
1、按照接线图所示正确接线,监控装置上电,180s 后继电器闭合;
1, wiring diagram shown in accordance with the correct wiring, power monitoring device, 180s relay is closed;
2、如果遇到过(欠)电压故障,过(欠)压保护动作,继电器断开;保护动作后,当介入电压恢复到 115%以 下(85%以上),监控装置判断电压稳定,180s 后自动复位,继电器闭合。
2, if encountered (under voltage fault), over (under) pressure protection, relay protection, disconnection; when involved in the voltage recovery below 115% (more than 85%), determine the monitoring device voltage stability, automatic reset 180s, closed relay.
电压动作示意图Schematic diagram of voltage action
注意事项Pay attention to matters:
T1:系统上电后判断额定电压的时间
T1:The time to judge the rated voltage after the system is on the system
T0:继电器复位样式时间 欠压后恢复电压时,如果电压波动低于门限,继电器保持断开;
T0:If the voltage fluctuation is lower than the threshold when the relay reset style is under voltage, the relay is kept off.
如果电压波动低于返回系数但不低于门限,则等待 信号恢复到返回系数后重新计时过压后恢复电压时,如果电压波动超过门限,继电器保持断开;
If the voltage fluctuation is lower than the return coefficient, but it is not less than the threshold, when the waiting signal is restored to the return coefficient, it will resume the voltage after overvoltage, and if the voltage fluctuation exceeds the threshold, the relay will remain open.
如果电压波动高于返回系数但不超过门限,则等待信号恢复到返回系数后重新计时
If the voltage fluctuation is higher than the return coefficient but does not exceed the threshold, the waiting signal is restored to the return coefficient and recounts.
HSKJ机柜空调系列产品特点:
HSKJ机柜空调系列控制柜内部元器件密集、发热量大,由于散热不良、升温过高导致的系统故障相当普遍。传统的冷却方式是风扇直接降温,散热效果差。机柜空调,可有效降低控制柜内部温度,并能阻止灰尘、湿气及腐蚀性气体进入控制柜内部,适用于可靠性要求较高的电气控制柜、计算机(服务器)机柜的温、湿度控制,是电控系统可靠工作的有力保障。
机柜空调器在国外已被广泛应用于数据处理、通讯、金融、冶金、石化、建材、汽车、机床、军工等各个领域,目前国内的一些大型数据处理中心及数控加工中心也广泛使用。机柜空调器的卓越功效及优良性能正在逐步被原来越多的国内用户高度认可。
HSKJ机柜空调系列产品参数表:
HSKJ机柜空调系列产品常用规格型号:
HSKJ机柜空调系列可根据客户要求定制,欢迎来电洽谈:13817080787!
eSaver是专为酒店、宾馆开发的空调节电器,传统的空调控制器使用红外技术控制空调温度,容易会引起酒店住客反感,eSaver使用新型的温控技术,不拆动空调,不改变空调结构,不调节空调温度,自动控制空调温度。
二、主要功能简介
1、 适用于所有分体空调(380V电压及功率大于2P的空调需要定制eSaver);
2、 可设置夏季模式和冬季模式,每个模式设置有一个限温值;
3、 根据设定的模式(夏季模式和冬季模式)和限温值自动控制环境温度;
4、 当空调启动时eSaver自动启动,当空调停止时eSaver自动停止;
5、 遥控参数设置功能,可通过遥控器配置eSaver的各种参数;
6、 报警功能,当eSaver的容差盒与主机断开或故障时蜂鸣器鸣叫;
7、 可配置故障保护功能,当出现故障,蜂鸣器鸣叫,可主动切断空调电源,保护空调;
8、 可配置远程通讯功能(RS485,以太网,WIFI,无线射频);
三、产品技术参数
² 物理尺寸:211*95*32mm
² 重量:约0.3kg
² 安装方式:插座式(安装在原空调插座位置)
² 工作温度:-15℃~50℃
² 工作湿度:10%到95%(无凝露)
² 最大制冷补偿温度:10摄氏度
² 最大制热温度:40摄氏度
² 功耗:小于3.5W
一、 酒店应用背景
我国推荐家用,酒店空调,学校,公共场所夏季设置的温度为26至27度。一是为了节能,避免不必要的能源浪费,二是从健康的角度来说,盛夏期间室内与室外最好温差为4至5摄氏度,这样能防止因室内外温差过大而患病感冒,甚至得“空调病”,但在实际实用过程中,特别是酒店的空调使用,住客往往会调整温度到低温状态,有的甚至调到最低温,在凌晨两点至六点时人体温度会下降,此时如果室温过低极易影响到住客的健康,同时也极大的浪费了能源。
大型酒店大多应用中央空调,投资大,可以集中管理,有效节能,但经济型酒店、宾馆因为客房数量不大,大多使用更经济的分体空调。
传统的分体空调控制是使用红外控制空调,极易引起住客的反感,酒店需要一款安装简单,使用方便,控温节能效果好,不引起客户反感的节电器,能保证在满足客户舒适度的前提下达到节能的目的。
二、 eSaver主要功能
1、 适用于所有分体空调(380V电压及功率大于2P的空调需要定制eSaver);
2、 可设置夏季模式和冬季模式,每个模式设置有一个限温值;
3、 根据设定的模式(夏季模式和冬季模式)和限温值自动控制环境温度;
4、 当空调启动时eSaver自动启动,当空调停止时eSaver自动停止;
5、 遥控参数设置功能,可通过遥控器配置eSaver的各种参数;
6、 报警功能,当eSaver的容差盒与主机断开或故障时蜂鸣器鸣叫;
7、 可配置故障保护功能,当出现故障,蜂鸣器鸣叫,可主动切断空调电源,保护空调;
8、 可配置远程通讯功能(RS485,以太网,WIFI,无线射频);
9、正常使用情况下,节电率可达20-80%。
三、 eSaver应用
适用于使用分体空调的酒店,宾馆的空调节能。
四、 eSaver技术参数
² 物理尺寸:211*95*32mm
² 重量:约0.3kg
² 安装方式:插座式(安装在原空调插座位置)
² 工作温度:-15℃~50℃
² 工作湿度:10%到95%(无凝露)
² 最大制冷补偿温度:10摄氏度
² 最大制热温度:40摄氏度
² 功耗:小于3.5W