规格 | 容量 | 输入电源 | 输 出电压 | 重量(kg) | |||
相数 | (V) | (A) | (V) | (A) | |||
2/220 | 2 | 1 | 220 | 10 | 0-250 | 8 | 14 |
3/220 | 3 | 1 | 220 | 15 | 0-250 | 12 | 16 |
5/220 | 5 | 1 | 220 | 25 | 0-250 | 20 | 18 |
10/220 | 10 | 1 | 220 | 50 | 0-250 | 40 | 80 |
15/380 | 15 | 2 | 380 | 37.5 | 0-430 | 34.8 | 90 |
20/380 | 20 | 2 | 380 | 50 | 0-430 | 46.5 | 100 |
25/380 | 25 | 2 | 380 | 62.5 | 0-430 | 58.1 | 120 |
30/380 | 30 | 2 | 380 | 75 | 0-430 | 69.7 | 140 |
50/380 | 50 | 2 | 380 | 125 | 0-430 | 116.2 | 160 |
100/380 | 100 | 2 | 380 | 250 | 0-430 | 232.5 | 250 |
说明:如有特殊参数要求,可按用户的技术参数进行设计制作。 |
规格 | 容量 kVA | 低压侧 | 高压侧 | 高压侧(交直流变压器) | 测量变比 | 60分钟温升℃ | 阻抗电压% | 空载电流 % | 质量 kg | |||
电压 V | 电流 A | 交流输出 | 直流输出 | |||||||||
电压kV | 电流 | 电压kV | 电流 | |||||||||
1.5/50 | 1.5 | 200 | 7.5 | 50 | 30 | 70 | 21.4 | 500 | 50 | 10 | <4 | 19.5 |
3/50 | 3 | 200 | 15 | 50 | 60 | 70 | 42.9 | 500 | 50 | 10 | <4 | 27 |
5/50 | 5 | 200 | 25 | 50 | 100 | 70 | 71.4 | 500 | 50 | 10 | <4 | 52 |
10/50 | 10 | 200 | 50 | 50 | 200 | 70 | 142.9 | 500 | 50 | 10 | <4 | 80 |
15/50 | 15 | 400 | 37.5 | 50 | 300 | 70 | 214.3 | 500 | 50 | 8 | <4 | 120 |
20/50 | 20 | 400 | 50 | 50 | 400 | 70 | 285.7 | 500 | 50 | 8 | <4 | 140 |
30/50 | 30 | 400 | 75 | 50 | 600 | 70 | 428.6 | 500 | 50 | 8 | <4 | 155 |
50/50 | 50 | 400 | 125 | 50 | 1000 | 70 | 714.3 | 500 | 50 | 8 | <4 | 184 |
10/100 | 10 | 200 | 50 | 100 | 100 | 140 | 71.4 | 1000 | 50 | 10 | <4 | 135 |
15/100 | 15 | 400 | 37.5 | 100 | 150 | 140 | 107.1 | 1000 | 50 | 8 | <4 | 150 |
20/100 | 20 | 400 | 50 | 100 | 200 | 140 | 142.9 | 1000 | 50 | 8 | <4 | 215 |
30/100 | 30 | 400 | 75 | 100 | 300 | 140 | 214.3 | 1000 | 50 | 8 | <4 | 250 |
50/100 | 50 | 400 | 125 | 100 | 500 | 140 | 357.1 | 1000 | 50 | 8 | <4 | 290 |
10/150 | 10 | 200 | 50 | 100 | 66.7 | 140 | 47.6 | 1500 | 50 | 10 | <4 | 180 |
15/150 | 15 | 400 | 37.5 | 150 | 100 | 210 | 71.4 | 1500 | 50 | 8 | <4 | 200 |
20/150 | 30 | 400 | 50 | 150 | 133.3 | 210 | 95.2 | 1500 | 50 | 8 | <4 | 220 |
30/150 | 30 | 400 | 75 | 150 | 200 | 210 | 142.9 | 1500 | 50 | 8 | <4 | 280 |
50/150 | 50 | 400 | 125 | 150 | 333.3 | 210 | 238.1 | 1500 | 50 | 8 | <4 | 340 |
说明:如有特殊参数要求,可按用户的技术参数进行设计制作。 上表的重量以油浸式试验变压器为例,干式试验变压器和充气式试验变压器稍有不同。 |
一.概述
HZ-C05系列吸油烟机空气性能试验装置是根据GB/T17713-2011《吸油烟机》GB/T14806-2003 《家用和类似用途的交流换气扇及其调速器》等标准研发制造的风量测量系统。该空气性能试验装置主要针对GB/T17713-2011《吸油烟机》标准附录C的“外排式吸油烟机空气性能试验装置”,该装置只能针对“外排式吸油烟机”做测试,不能用于“循环式吸油烟机”测试。
其基本测试原理是:在测试风洞中模拟试品的实际工作状态,变换出风口的孔板直径,然后测出风口的每次静压值,再由标准公式计算出此时对应的的流量系数及风量等参数。
该装置采用计算机自动测控方式,只需人工安装试品和更换孔板,测试一台试品全过程只需十分钟。可以测绘静压与风量、风量与转速、电流、功率、效率等对应曲线。具有方便快捷、稳定可靠、重现性好等特点。满足相关产品的科研和生产过程中测试使用。
产品名称:吸油烟机空气性能试验装置
型号规格:HZ-C05
标准依据: GB/T 17713-2011、GB/T14806-2003等相关产品标准。
适用产品: 吸油烟机、管道式换气扇、送风机等。
性能及特点要求:
1) 由电脑及其周边设备实现自动测试、演算及数据输出,图形显示打印测试结果。人机对话操作简单,精度高,省时省力。
2) 测试项目:P-Q特性(流量与静压的关系)、Q-η特性(流量与效率的关系)、同步测定被测体的转速、电流、功率。
二.总体方案
本方案不包括试验室建筑结构部分,该部分由用户根据标准要求自行建造。
1.试验室一般要求
尺寸:3500(宽)×5000(长)×2800(高)mm以上。
墙壁:光滑平整,没有影响气流的开孔(空调开孔不应直吹)。
地面:应保持地面平整。
温湿度:风量测量时试验室空气温度为 20℃±5℃、湿度为 30%-80%。
大气压:海拔不超过1000米的普通大气环境。
2.测试系统
主要构成:风量测试风洞、出风口调节孔板、测控电气柜(包括变频电源、电参数测量仪、压力变送器、转速表等)、品牌电脑、打印机、试品升降台、试品安装法兰及测试风管。
系统功能:由计算机提示输入试品参数和测试相关数据后,便可实现全部自动测控功能:包括、风量测量;电压、电流、功率测量;转速测量、温湿度和大气压测量、测试过程提示、数据表格、相关曲线等。
3.配电要求:用户须提供独立的配电开关,单相二线加地线供电:
AC 220V,50Hz 最大容量:2KVA
德国PTL压痕试验装置 IEC60811压痕试验仪供应进口压痕测试装置
PTL压痕装置用于插头的插脚绝缘套管和直径达20mm
电线和电缆在200°C负载达11.5N的压力测试,根据IEC 60811-3-1 / 1985 + 表 May 1986&8.1.3
和 & 8.2.3 图. 1, EN 60811-3-1 / 草稿 1994&8.1.3
and &8.2.3 图. 1, VDE 0473 811-3-1 部分/ 草稿 1995-01 & 8.1.3
and & 8.2.3图. 1
Standard outfit:
1 base plate, dimensions of the floor space 100 mm x 150 mm,
1 stand, with support, with plane sample bearing surface,
1 testing frame, mass including blade 25,5 g, exerted load 0,25 N,
1 straight blade, hardened and ground, 0,7 +0,01 mm thick, exchangeable,
1 load carrier, mass 25,5 g, for fitting the load weights, exerted load 0,25 N,
1 set of load weights, to load the sample with forces from 0,5 N to 11,5 N in steps of 0,01 N.
Design:base plate and small weight pieces of aluminum, all other parts of steel browned or nickel plated, bearing surface of the support ground, total height approx.
270 mm with sample diameter 20 mm, Article No.: T 13.10
alternative:
PTL Indentation Device 20
as above, but for simultaneous testing of 2 samples, with 2 testing frames, 2 load carriers and 2 sets of load weights, stand with bearing support T-shaped,
Article No.: T 13.20
Rounded blade with radius 6 mm according to IEC 60884-1 / 1994 Fig. 29:on request
PTL Indentation Devices as multiple devices for 3 or more samples: on request
PTL Indentation Devices according to DIN 72 551 Part 5&3.4.2 Fig. A.2: on request
BG5105线缆低温冲击、低温卷绕、低温拉伸试验装置成套设备
适用范围:
本试验机是本公司最新研制的的一款低温拉伸、卷绕自动智能为一体式的试验机,该设备采用了人机界面控制,智能化操作方便更简单,并配有微型打印机,打印测试数据。本设备包括四台设备:高低温试验箱,电动低温拉伸试验装置,低温卷绕试验装置,低温冲击试验装置
高低温试验箱是模拟高低温环境,广泛用于确定电工、电子产品对高低温环境的适应性(特别是产品的电气性能和机械性能的变化情况),也可用于检查试样耐受某些腐蚀的能力。
对应标准:
GB/T2951-2008主要技术指标:
低温卷绕试验装置一般适用于外径12.5mm及以下的圆形绝缘线芯及不能制备哑铃试件的扇形绝缘线芯。若有关电缆产品标准中规定,试验应在大尺寸绝缘线芯上进行。否则,大尺寸绝缘线芯应进行低温拉伸试验。
电动低温拉伸试验装置适用于高分子材料,电线电缆,橡胶、塑料绝缘护套在0~-40℃/-60℃/-70℃环境下进行拉伸的试验仪器,其结构和性能均满足GB/T2951-2008标准要求。
低温冲击试验装置适用于各种聚氯乙烯护套电缆,而与绝缘线芯的绝缘类型无关。如果有关电缆产品标准有规定,也适用于无护套的电线、软线和扁平软线的聚乙烯绝缘。护套电缆的聚氯乙烯绝缘不直接进行低温冲击试验。
u 低温箱工作尺寸:500×600×500mm;
u 温度范围: -40℃/-60℃/-70℃~150℃;
u 温度波动度: ±0.5℃ (空载时);
u 温度偏差: ≤±2℃;
u 升降温平均速率: 0.7℃~1.0℃/min (空载时);
u 时间设定范围: 0~9999 小时;
u 拉伸装置:电机:90W ,安装于低温箱内;
Ø 最大拉伸度:220mm ;
Ø 拉伸速度:20~30mm/min ;
Ø 夹头型式:非自紧式;
Ø 试样规格:Ⅰ、Ⅱ号哑铃片;
Ø 数据显示:直读伸长率;
u 卷绕装置:卷绕试样直径:Ф2.5~Ф12.5mm;
Ø 卷绕棒直径:Ф4.0~Ф50mm共17支;
Ø 过线套:Ф1.2~Ф14.5mm共10种,各二件;
Ø 试样缠绕圈数:2~10圈;
Ø 卷绕速度:5s/圈;
u 冲击装置:冲击高度:100mm;
Ø 砝码:100、200、300、400、500、600、750、1000、1250、1500g ;
Ø 本系列装置全为不锈钢制作;
Ø 本装置可分为单组式与三组式;
u 外形尺寸:根据客户的选型提供;
u 电源:AC 220V 50/60Hz 20A。
FRC系列交直流分压器高压试验装置是现场测量用的用仪器仪表,主要用于脉冲高压,雷电高压,工频高压的测量以及电力系统及电气、电子设备制造部门工频交流高电压和直流高电压的测量。
产品特征
1、精度高AC:0.1 DC:0.1
是高压静电电压表的更新换代新型产品
2、读数方便
FRC系列分压器由高压分压器上端均压罩为高压端,可直接接入被测高压,下端有用接地端,供接地使用,用用电缆连接高压分压器和低压显示仪表,并选择相应的电压和量限即可开始测量,读数即为“kV”
3、安全可靠
FRC系列分压器是由高压测量部分和低压显示仪表构成。工作时高压部分和低压仪表分开,实施安全可靠
产品别称
多功能交直流分压器、交直流分压器、交直流高压测量装置、高压分压器、阻容分压器、分压器、阻容式交直流分压器、千伏电压表、千伏表、
技术参数
准确度及高压阻抗
电压等 | AC/DC50kV | AC/DC100kV | AC/DC200kV | AC/DC300kV | |
分压比 | 1000:1 | 1000:1 | 1000:1 | 1000:1 | |
阻 抗 | 200MΩ | 400MΩ | 800MΩ | 1200MΩ | |
精确度 | 直流值 | 1.0 | 1.0 | 1.0 | 1.0 |
交流值 | 1.5 | 1.5 | 1.5 | 1.5 | |
重 量 | 10kg | 15kg | 25kg | 35kg |
2、工作环境
温度:0~40℃
湿度:≤85%RH
其他电压等可根据客户要求定制
更多交直流分压器高压试验装置信息:http://www.whhnlc.com/home/6
推荐详情:直流高压发生器 http://www.whhnlc.com/home/21 接地电阻测试仪 http://www.whhnlc.com/home/53
依据GB/T 328.25-2007《建筑防水卷材试验方法 第25部分:沥青和高分子防水卷材 抗静态荷载》中第5.7条真空或压力装置对仪器的要求设计制造的。适用沥青和高分子防水卷材以及其它防水卷材做抗静态荷载穿刺或抗冲击后,其穿透性能的检测。具有结构简单,操作方便的特点。
技术参数
1.压力表测量范围:0~25KPa
ZSY-27真空穿透试验装置
依据GB/T 328.25-2007《建筑防水卷材试验方法 第25部分:沥青和高分子防水卷材 抗静态荷载》中第5.7条真空或压力装置对仪器的要求设计制造的。适用沥青和高分子防水卷材以及其它防水卷材做抗静态荷载穿刺或抗冲击后,其穿透性能的检测。具有结构简单,操作方便的特点。
技术参数
1.压力表测量范围:0~25KPa
专业冲水装置,IP5IP6冲水试验装置,手持式冲水试验装置 产品特点:
本产品是模拟淋水的环境试验设备,主要是考核电工电子产品外壳和密封件在喷水试验后和在试验期间能否保证设备和元件良好的工作性能。本设备满足GB/T4942.1-2006《旋转电机整体结构的防护等级分级》
GB/T4942.2-1993《低压电器外壳防护等级》
符合GB/T4942.2-1993中表4第5条款、第6条款要求,防护等级IPX5和IPX6
符合GB/T4942.1-2006中表5第5条款、第6条款要求,防护等级IP5X和IPX6
型号规格:
型号:IPX5/X6
IPX5,IPX6冲水装置的技术规格 1、喷水口径:IPX5为ø 6.3㎜ IPX6为ø 12.5 ㎜(附图)
喷头材质:304不锈钢,IPX5、IPX6喷嘴螺纹联接、快速更换
2、喷水水压:30~100kpa 3、 喷水量: IPX5试验喷水流量:12.5±0.625L/min
IPX6试验喷水流量: 100±5L/min
4.喷嘴至试验件外壳表面距离:2.5m~3m 5.冲水试验装置说明及组成: 装置说明:本装置按《GB4208-2008外壳防护等级IP代码》中技术要求IP×5 ,IP×6第二特征数字5,6)设计制造。 防喷试验时,可移动至任何一处适合场所防喷试验,按所须要求调节好流量、压力、时间及喷射范围。即可进行试验。 装置组成: 试验装置由蓄水箱(500L)、加压水泵、调减压阀、流量调节器(2只)、压力表、耐 压水管、分流装置及喷射支架电器控制箱等组成。 储水箱:加厚型高级拉丝不锈钢氩弧焊接制成。 喷射支架:不锈钢精加工制成,符合GB4208外壳防护IP代码技术要求。 6、冲水试验装置水压控制系统: a、用流量计调节压力大小 b、泄压手动调节水阀 c、配备水过滤器 7、冲水试验装置符合标准:本设备是按GB/T4208-2008有关技术参数设计制作。
适用于检验将插头从插座拔出所需要的最大力及单极插销从插套组件拔出的所需要的最小力是否在标准规定的范围内;
配置:二极10A、三极10A和16A试验标准插头各一个;
10A、16A试验标准插销各一个;