消防水软管站SJP-8、SJP-16,比例混合器流量范围为:4~8L/s、8~16L/s,工作压力范围:0.6-1.2MPa,卷盘长度20m,泡沫枪射程≥18~28m。
表Table 1
名称 Name | 型号 Type | 工作压力范围 Working pressure | 额定工作压力rated working pressure | 储罐容量 Storage tank volume | 混合比 Mixing ratio | 流量范围 The range of flow | 射程 Range | 进出口压差 Differential pressure between inlet and outlet |
消防水/泡沫软管站 Fire water / foam hose reel station | PJP-8 | 0.6-1.2MPa | 0.7 MPa | 100~700L(可根据实际工程确定) According to the actual engineering | 3%或6% | 8L/s±8% | ≥18m | ≤0.2MPa |
PJP-16 | 16L/s±8% | |||||||
|
|
|
|
|
|
|
|
|
表Table 2
名称Name | 型号Type | 工作压力范围 Working pressure | 额定工作压力Rated working pressure | 流量范围 The range of flow | 射程 Range |
消防水软管站 Fire water hose reel station | SJP-8 | 0.6-1.2MPa | 0.7 MPa | 8L/s±8% | ≥18~28m |
SJP-16 | 16L/s±8% |
2.2软管站安装尺寸及质量(不含泡沫液)
The installation dimension and quality of hose reel station (Excluding foam liquid)
表Table 3
名称Name | 型号 Type | 消防水进口通径(mm) Inlet diameter of fire water(mm) | 外形尺寸(mm) Outside dimension | 重量(kg) Weight |
消防水/泡沫软管站 Fire water / foam hose reel station | PJP-8 | DN50 | 680×560×1245 | 180 |
PJP-16 | ||||
消防水软管站 Fire water hose reel station | SJP-8 | 130 | ||
SJP-16 |
关键词:泡沫软管站 消防水/泡沫软管站