日本横河EJA120A微差压变送器产品简介
EJA120A微差压变送器用于测量微小差压,然后将其转变成4-20mADC的电流信号输出。
EJA120A也可以通过BRAIN手操器或CENTUM CS/μXL或HART 275手操器相互通讯,通过它们进行设定和监控等。
日本横河EJA120A微差压变送器产品规格
应用 | 类型 | 型号 | 膜盒 | 量程(KPa) | 最大工作压力(KPa) |
微差压 | 常规安装 | EJA120A | E | 0.1-1 | 50 |
横河EJA120系列微差压变送器EJA120A-DES4A-92DA EJA120A-EES4A-92DA EJA120A-DES5A-92DA EJA120A-EES5A-92DAEJA120A-DES4A-22DC EJA120A-EES4A-22DC EJA120A-DES5A-22DC EJA120A-EES5A-22DCEJA120A-DES4A-92NA EJA120A-EES4A-92NA EJA120A-DES5A-92NA EJA120A-EES5A-92NAEJA120A-DES4A-22NC EJA120A-EES4A-22NC EJA120A-DES5A-22NC EJA120A-EES5A-22NCEJA120A-DES4A-92DN EJA120A-EES4A-92DN EJA120A-DES5A-92DN EJA120A-EES5A-92DNEJA120A-DES4A-22DN EJA120A-EES4A-22DN EJA120A-DES5A-22DN EJA120A-EES5A-22DNEJA120A-DES4A-92NN EJA120A-EES4A-92NN EJA120A-DES5A-92NN EJA120A-EES5A-92NNEJA120A-DES4A-22NN EJA120A-EES4A-22NN EJA120A-DES5A-22NN EJA120A-EES5A-22NNEJA120A-DES4A-92DA/NF1 EJA120A-EES4A-92DA/NF1 EJA120A-DES5A-92DA/NF1EJA120A-EES5A-92DA/NF1 EJA120A-DES4A-22DC/NF1 EJA120A-EES4A-22DC/NF1EJA120A-DES5A-22DC/NF1 EJA120A-EES5A-22DC/NF1 EJA120A-DES4A-92NA/NF1EJA120A-EES4A-92NA/NF1 EJA120A-DES5A-92NA/NF1 EJA120A-EES5A-92NA/NF1EJA120A-DES4A-22NC/NF1 EJA120A-EES4A-22NC/NF1 EJA120A-DES5A-22NC/NF1EJA120A-EES5A-22NC/NF1 EJA120A-DES4A-92DN/NF1 EJA120A-EES4A-92DN/NF1EJA120A-DES5A-92DN/NF1 EJA120A-EES5A-92DN/NF1 EJA120A-DES4A-22DN/NF1EJA120A-EES4A-22DN/NF1 EJA120A-DES5A-22DN/NF1 EJA120A-EES5A-22DN/NF1EJA120A-DES4A-92NN/NF1 EJA120A-EES4A-92NN/NF1 EJA120A-DES5A-92NN/NF1EJA120A-EES5A-92NN/NF1 EJA120A-DES4A-22NN/NF1 EJA120A-EES4A-22NN/NF1EJA120A-DES5A-22NN/NF1 EJA120A-EES5A-22NN/NF1 EJA120A-DES4A-92DA/NS1EJA120A-EES4A-92DA/NS1 EJA120A-DES5A-92DA/NS1 EJA120A-EES5A-92DA/NS1EJA120A-DES4A-22DC/NS1 EJA120A-EES4A-22DC/NS1 EJA120A-DES5A-22DC/NS1EJA120A-EES5A-22DC/NS1 EJA120A-DES4A-92NA/NS1 EJA120A-EES4A-92NA/NS1EJA120A-DES5A-92NA/NS1 EJA120A-EES5A-92NA/NS1 EJA120A-DES4A-22NC/NS1EJA120A-EES4A-22NC/NS1 EJA120A-DES5A-22NC/NS1 EJA120A-EES5A-22NC/NS1EJA120A-DES4A-92DN/NS1 EJA120A-EES4A-92DN/NS1 EJA120A-DES5A-92DN/NS1EJA120A-EES5A-92DN/NS1 EJA120A-DES4A-22DN/NS1 EJA120A-EES4A-22DN/NS1EJA120A-DES5A-22DN/NS1 EJA120A-EES5A-22DN/NS1 EJA120A-DES4A-92NN/NS1EJA120A-EES4A-92NN/NS1 EJA120A-DES5A-92NN/NS1 EJA120A-EES5A-92NN/NS1EJA120A-DES4A-22NN/NS1 EJA120A-EES4A-22NN/NS1 EJA120A-DES5A-22NN/NS1 EJA120A-EES5A-22NN/NS1
横河EJA120A微差压变送器
EJA120A微差压变送器产品特性 - 的性能和稳定性 EJA系列采用单晶硅谐振式传感器技术。单晶硅对于压力或温度的变化不存在滞后现象,是非常理想的材料。单晶硅谐振式传感器将过压、温度变化和静压影响降为,从而提供无与伦比的稳定性。 - 小型轻量设计 由于采用ASIC放大器设计使包装变小,以及膜盒构造和法兰的小型化,这款机型的重量降到了原有机型的一半。ASIC设计不仅减少了零件数量,而且提高了放大器的性。 - 现场总线通信能力 现场总线是双向数字通信系统,是配置仪表控制系统的革新技术,同时也是前景很好的更新换代产品,用于替换现在现场仪表中广泛使用的标准4~20mA模拟通信。 EJA系列提供两种现场总线模式,FOUNDATION&#8482;现场总线低压模式和PROFIBUS PA设备,以实现横河电机和其他供应商的协同工作。软件方面,EJA系列采用两个AI功能块计算差压和静压,从而实现灵活的仪表配置。 世界首创—单晶硅谐振传感器。高精度: 0.075%, 连续工作五年不需调校, 温度影响可忽略不计,静压影响可忽略不计。单向过压影晌:连续10万次单向过压实验后影晌量< 0.03%, 双向通讯功能(BRAIN/HART协议,FF现场总线),完善的自诊断功能。基本品接液膜片材质:哈氏合金C-276小型、轻量(标准型3.9kg) 型号: EJA 110A差压变送器 EJA 120A微差压变送器 EJA 130A高静压差压变送器 EJA 210A/220A法兰安装式差压变送器 EJA 310A绝对压力变送器 EJA 430A压力变送器 EJA 440A高压力变送器 EJA 510A绝对压力变送器/530A压力变送器 EJA 118W/118 N/118Y隔膜密封式差压变送器 EJA 438W/438N隔膜密封式压力变送器 EJA 115微小流量变送器 EJA 213卫生型变送器 EJA压力变送器用于测量液体、气体和蒸汽液位、密度和压力,然后将其转变成4-20mADC的电流信号输出。EJA也可HART275手操器相互通讯,通过它们进行设定、监控等。产品型号:EJA110A、EJA120A、130A、210A、310A、430A、440A、510A、118W
日本横河EJA120A微差压变送器中国总代理EJA120A微差压变送器用于测量微小差压,然后将其转变成4-20mADC的电流信号输出。EJA120A也可以通过BRAIN手操器或CENTUM CS/μXL或HART 275手操器相互通讯,通过它们进行设定和监控等。
日本横河EJA120A微差压变送器用于测量微小差压,然后将其转变成4-20mADC的电流信号输出。横河EJA120A差压变送器也可以通过BRAIN手操器或CENTUM CS/μXL或罗斯蒙特HART475手操器相互通讯,通过它们进行设定和监控等。
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
选型 基本规格代码:EJA120A-DES5A-92NN
|
| | | | | |
| | | | | |
横河EJA详细介绍:EJA110A/130A 差压变送器;EJA120A 微差压变送器;EJA210A/220A 差压变送器法兰型;EJA118W/N/Y 远传法兰型;EJA430A/440A 压力变送器;EJA510A/530A 绝对压力/压力变送器;EJA438W/N 压力变送器远传法兰型;EJA115 微小流量变送器;EJA213/223 卫生型液位变送器;EJA113W/433W 卫生型隔膜密封式差压变送器;EJA 系列HART通讯变送器;EJA系列FF现场总线通讯变送器;BT200 手持智能终端;
邮箱:whprskj@163.com
1、EJA变送器采用单晶硅谐振传感器,直接将压力信号转换成数字信号处理,减少A/D转换环节,有利于整个回路精度的提高。 2、EJA变送器的单晶硅谐振传感器是数字式传感器,采用频率差减能自动消除温度,静压等的影响, 3、EJA变送器具有的单向和大压力过压能力,在24小时内10万次16MPa冲击的影响量小于0.03%,产品性高,质量稳定, 3、EJA变送器可以无须三阀组安装,节约设备投资成本,减少设备维护,减少故障点。 4、EJA变送器全系列均同一品质,均为高质量产品, 5、只要使用了EJA变送器,用户可以直接和横河川仪公司联系,横河川仪公司直接对售后服务和产品质量负责。 6、变送器基本品材质——膜片:哈氏合金;容室法兰:不锈钢;容室密封环:软316L。而3051为膜片:316L;容室法兰:碳钢;密封环:橡胶。 7、EJX是目前世界上变送器标准品中能够达到国际电子工业安全性认证SIL2标准的变送器,安全性远远高于其他变送器。 产品特性 - 的性能和稳定性 EJA系列采用单晶硅谐振式传感器技术。单晶硅对于压力或温度的变化不存在滞后现象,是非常理想的材料。单晶硅谐振式传感器将过压、温度变化和静压影响降为,从而提供无与伦比的稳定性。 - 小型轻量设计 由于采用ASIC放大器设计使包装变小,以及膜盒构造和法兰的小型化,这款机型的重量降到了原有机型的一半。ASIC设计不仅减少了零件数量,而且提高了放大器的性。 - 现场总线通信能力 现场总线是双向数字通信系统,是配置仪表控制系统的革新技术,同时也是前景很好的更新换代产品,用于替换现在现场仪表中广泛使用的标准4~20mA模拟通信。 EJA系列提供两种现场总线模式,FOUNDATION&#8482;现场总线低压模式和PROFIBUS PA设备,以实现横河电机和其他供应商的协同工作。软件方面,EJA系列采用两个AI功能块计算差压和静压,从而实现灵活的仪表配置。 世界首创—单晶硅谐振传感器。高精度: 0.075%, 连续工作五年不需调校, 温度影响可忽略不计,静压影响可忽略不计。单向过压影晌:连续10万次单向过压实验后影晌量< 0.03%, 双向通讯功能(BRAIN/HART协议,FF现场总线),完善的自诊断功能。基本品接液膜片材质:哈氏合金C-276小型、轻量(标准型3.9kg) 型号: 横河EJA110A差压变送器 横河EJA120A微差压变送器 横河EJA130A高静压差压变送器 横河EJA210A/220A法兰安装式差压变送器 横河EJA310A绝对压力变送器 横河EJA430A压力变送器 横河EJA440A高压力变送器 横河EJA510A绝对压力变送器/530A压力变送器 横河EJA118W/118 N/118Y隔膜密封式差压变送器 横河EJA438W/438N隔膜密封式压力变送器 横河EJA115微小流量变送器 横河EJA213卫生型变送器 横河EJA压力变送器用于测量液体、气体和蒸汽液位、密度和压力,然后将其转变成4-20mADC的电流信
号输出。EJA也可HART275手操器相互通讯,通过它们进行设定、监控等。产品型号:EJA110A、EJA120A、130A、210A、310A、430A、440A、510A、118W
横河EJA变送器系列:横河EJA120系列微差压变送器EJA120A-DES4A-92DA EJA120A-EES4A-92DA EJA120A-DES5A-92DA EJA120A-EES5A-92DAEJA120A-DES4A-22DC EJA120A-EES4A-22DC EJA120A-DES5A-22DC EJA120A-EES5A-22DCEJA120A-DES4A-92NA EJA120A-EES4A-92NA EJA120A-DES5A-92NA EJA120A-EES5A-92NAEJA120A-DES4A-22NC EJA120A-EES4A-22NC EJA120A-DES5A-22NC EJA120A-EES5A-22NCEJA120A-DES4A-92DN EJA120A-EES4A-92DN EJA120A-DES5A-92DN EJA120A-EES5A-92DNEJA120A-DES4A-22DN EJA120A-EES4A-22DN EJA120A-DES5A-22DN EJA120A-EES5A-22DNEJA120A-DES4A-92NN EJA120A-EES4A-92NN EJA120A-DES5A-92NN EJA120A-EES5A-92NNEJA120A-DES4A-22NN EJA120A-EES4A-22NN EJA120A-DES5A-22NN EJA120A-EES5A-22NNEJA120A-DES4A-92DA/NF1 EJA120A-EES4A-92DA/NF1 EJA120A-DES5A-92DA/NF1EJA120A-EES5A-92DA/NF1 EJA120A-DES4A-22DC/NF1 EJA120A-EES4A-22DC/NF1EJA120A-DES5A-22DC/NF1 EJA120A-EES5A-22DC/NF1 EJA120A-DES4A-92NA/NF1EJA120A-EES4A-92NA/NF1 EJA120A-DES5A-92NA/NF1 EJA120A-EES5A-92NA/NF1EJA120A-DES4A-22NC/NF1 EJA120A-EES4A-22NC/NF1 EJA120A-DES5A-22NC/NF1EJA120A-EES5A-22NC/NF1 EJA120A-DES4A-92DN/NF1 EJA120A-EES4A-92DN/NF1EJA120A-DES5A-92DN/NF1 EJA120A-EES5A-92DN/NF1 EJA120A-DES4A-22DN/NF1EJA120A-EES4A-22DN/NF1 EJA120A-DES5A-22DN/NF1 EJA120A-EES5A-22DN/NF1EJA120A-DES4A-92NN/NF1 EJA120A-EES4A-92NN/NF1 EJA120A-DES5A-92NN/NF1EJA120A-EES5A-92NN/NF1 EJA120A-DES4A-22NN/NF1 EJA120A-EES4A-22NN/NF1EJA120A-DES5A-22NN/NF1 EJA120A-EES5A-22NN/NF1 EJA120A-DES4A-92DA/NS1EJA120A-EES4A-92DA/NS1 EJA120A-DES5A-92DA/NS1 EJA120A-EES5A-92DA/NS1EJA120A-DES4A-22DC/NS1 EJA120A-EES4A-22DC/NS1 EJA120A-DES5A-22DC/NS1EJA120A-EES5A-22DC/NS1 EJA120A-DES4A-92NA/NS1 EJA120A-EES4A-92NA/NS1EJA120A-DES5A-92NA/NS1 EJA120A-EES5A-92NA/NS1 EJA120A-DES4A-22NC/NS1EJA120A-EES4A-22NC/NS1 EJA120A-DES5A-22NC/NS1 EJA120A-EES5A-22NC/NS1
日本横河EJA120A微差压变送器用于测量微小差压,然后将其转变成4-20mADC的电流信号输出。横河EJA120A差压变送器也可以通过BRAIN手操器或CENTUM CS/μXL或罗斯蒙特HART475手操器相互通讯,通过它们进行设定和监控等。
| EJA120A微差压变送器 | |
E膜盒 | ||
测量范围 | -1~1kPa(-4~4inH2O) | |
测量量程 | 0.1~1kPa(0.4~4inH2O) | |
精度 | ±0.2% | |
防护等级 | IP67,NEMA 4X,和JIS C0920防浸型 | |
防爆规格 | FM,CENELEC ATEX,CSA,IECEx | |
输出信号 | 4~20mA DC或FOUNDATION 现场总线或PROFIBUS PA两线制数字通信 | |
电源 | BRAIN和HART:10.5~42V DC (本安型: 10.5~30V DC) Fieldbus:9~32V DC (本安Entity模式9~24V DC,本安FISCO模式9~17.5V DC) | |
环境温度 | -25~80℃(-13~176℉) | |
过程温度 | -25~80℃(-13~176℉) | |
最大工作压力 | 50kPa (7.25psi) | |
安装 | 2-inch管安装 | |
接液部件材质 | 膜盒 | SUS316L(膜片: 哈氏合金C-276) |
容室法兰 | SUS316 | |
外壳 | 铝合金或SUS316不锈钢(可选) |
第1项:输出信号 |
| ||||||||||||||||
第2项:测量量程(膜盒) |
| ||||||||||||||||
第3项:接液件材质 |
| ||||||||||||||||
第4项:过程接口 |
| ||||||||||||||||
第5项:螺栓和螺母材质 |
| ||||||||||||||||
第6项:安装方式 |
| ||||||||||||||||
第7项:电气接口 |
| ||||||||||||||||
第8项:内藏显示表 |
| ||||||||||||||||
第9项:安装托架 |
|
横河EJA120A微差压变送器,差压变送器规格,横河EJA120A微差压变送器,差压变送器规格 横河差压变送器 横河EJA变送器
日本横河EJA120A微差压变送器用于测量微小差压,然后将其转变成4-20mADC的电流信号输出。横河EJA120A差压变送器也可以通过BRAIN手操器或CENTUM CS/μXL或罗斯蒙特HART475手操器相互通讯,通过它们进行设定和监控等。 我公司专业代理横河,罗斯蒙特,费希尔等品牌产品,欢迎您咨询和选购。
横河120A微差压变送器:横河120A测量量程0.1~1kPa; 横河120A精度: ±0.2% (包括从零点开始的线性,滞后性和重复性)横河120A输出信号: 4~20mA DC,BRAIN和HART两种通信协议可选 。横河120A电源:10.5~42V DC (本安型: 10.5~30V DC)过程温度: -40~120℃(普通型); 横河120A最大工作压力: 16MPaL膜盒(特殊材料)3.5MPa; DPharp EJA差压压力变送器(Differential Pressure/Pressure high accuracy resomamt sensor pressure transmitter)是一种高性能智能式差压、压力变送器,采用了世界上先进的单晶硅谐振式传感器技术,自投放市场以来,以其优良的性能受到客户好评。EJA在DPharp EJ变送器基础上实现了以下设计目标: 1、除保证高精度外,还实现了静压、温度等环境影响极小的高性能。 2、可长期连续使用的高可靠性。 3、小型、轻量,使其有受安装场所的限制,可自由安装。 4、采用了微型计算机技术,具有完整的自诊断功能和通讯功能。 5、开发时重视零点的稳定性,提高了维护效率。 EJA特点 ●世界首创—单晶硅谐振传感器 ●采用微电子机械加工高新技术(MEMS) ●传感器直接输出频率信号,简化与数字系统的接口 ●高精度,一般为±0.075% ●高稳定性和可靠性 ●连续十万次过压试验后影响量≤0.03%/16MPa ●连续工作五年不需要调校零点 ●BRAIN/HART/FF现场总线三种通讯协义供选择 ●完善的自诊断及远程设定通讯功能 ●可无需三阀组而直接安装使用 ●基本品的接液膜片材质为:哈氏合金C-276(小型标准为3.9kg) ●外部零点/量程调校 EJA120A-DES4A-92DA EJA120A-EES4A-92DA EJA120A-DES5A-92DA EJA120A-EES5A-92DAEJA120A-DES4A-22DC EJA120A-EES4A-22DC EJA120A-DES5A-92NA EJA120A-EES5A-92NAEJA120A-DES4A-22NC EJA120A-EES4A-22NC EJA120A-DES5A-22NC EJA120A-EES5A-22NC EJA120A-DES5A-22DC EJA120A-EES5A-22DCEJA120A-DES4A-92NA EJA120A-EES4A-92NA EJA120A-DES4A-92DN EJA120A-EES4A-92DN EJA120A-DES5A-92DN EJA120A-EES5A-92DNEJA120A-DES4A-22DN EJA120A-EES4A-22DN EJA120A-DES5A-22DN EJA120A-EES5A-22DN EJA120A-DES5A-92NN EJA120A-EES5A-92NNEJA120A-DES4A-22NN EJA120A-EES4A-22NN EJA120A-DES4A-92NN EJA120A-EES4A-92NN EJA120A-DES5A-22NN EJA120A-EES5A-22NN
产品概述:
横河EJA120A微差压变送器用于测量液体、气体或蒸汽的液位、密度与压力,然后将其转变成4~20mADC的电流信号输出。EJA120A也可与BRAIN手操器、YHC4150、CENTUMCS 、FieldMate、HART475互相通讯,通过它们进行设定、监控等。
作为高端微差压变送器,EJA120A具有以下特点:
1、调零:在墨盒量程的上下限范围内,零点可任意调整。
2、外部调零:在测量范围内零点连续可调,分辨率为0.01%,用表头的范围设定开关可对量程进行调校。
3、安装位置影响:与膜片面平行方向的安装位置变化不会造成零漂影响,若安装位置与膜片面超过90°的变化,在0.4KPa{1.6inH2O}范围内的零漂可通过调零校正。
4、出错报警:CPU或硬件出错时输出状态,上限输出:110%≥21.6mA DC(标准),下限输出:-5%,≤3.2mA DC- 2.5%,≤3.6mADC(适用于代码F1)注:只适用于输出信号为BRAIN或HART协议时。
5、阻尼系数可调:放大器部件和膜盒的阻尼时间常数之和。放大器部件阻尼时间常数在0.2~64秒范围可调。
6、环境温度:- 25~80℃( - 13~176 °F)
EJA120A-选型表
基本规格代码:EJA120A-DMS5A-92DA
第1项: 输出信号 |
| ||||||||||||||||
第2项: 测量量程(膜盒) |
| ||||||||||||||||
第3项: 接液件材质 |
| ||||||||||||||||
第4项: 过程接口 |
| ||||||||||||||||
第5项: 螺栓和螺母材质 |
| ||||||||||||||||
第6项: 安装方式 |
| ||||||||||||||||
第7项: 电气接口 |
| ||||||||||||||||
第8项: 内藏显示表 |
| ||||||||||||||||
第9项: 安装托架 |
|
三、附加功能
窗体顶端
第1项:隔爆型、本安型 |
| ||||||||||||||||||||||||||||||||||
第2项:隔爆密封接头 |
| ||||||||||||||||||||||||||||||||||
第3项:涂漆:颜色变化或涂漆变化 |
| ||||||||||||||||||||||||||||||||||
第4项:避雷保护器 |
| ||||||||||||||||||||||||||||||||||
第5项:禁油处理或禁水、禁油处理 |
| ||||||||||||||||||||||||||||||||||
第6项:校正单位 |
| ||||||||||||||||||||||||||||||||||
第7项:SUS630螺母的密封处理 |
| ||||||||||||||||||||||||||||||||||
第8项:长排气塞 |
| ||||||||||||||||||||||||||||||||||
第9项:快速应答 |
| ||||||||||||||||||||||||||||||||||
第10项:PID/LM功能 |
| ||||||||||||||||||||||||||||||||||
第11项:CPU异常时输出设定为低侧或NAMUK NE43 |
| ||||||||||||||||||||||||||||||||||
第12项:高精度 |
| ||||||||||||||||||||||||||||||||||
第13项:不锈钢放大器外壳 |
| ||||||||||||||||||||||||||||||||||
第14项:镀金膜片 |
| ||||||||||||||||||||||||||||||||||
第15项:组态 |
| ||||||||||||||||||||||||||||||||||
第16项:容室法兰选项 |
| ||||||||||||||||||||||||||||||||||
第17项:不锈钢位号牌 |
| ||||||||||||||||||||||||||||||||||
第18项:配件制造证明 |
| ||||||||||||||||||||||||||||||||||
第19项:压力测试漏压测试证明 |
|
S-150-13.5V,开关电源 电子计数器,SKX-64 微型电子计数器,SJ-607K S-150-27v ,开关电源 SJ-607S, 电子累时器 PR08-2DN(接近开关) 微型电子计数器,SJ-607D S-120-10V,开关电源 S-120-7.5V,开关电源 电子累时器,SL-605 开关电源,S-120-3V S-100-48V,开关电源 电子计数器,SKX-6D 开关电源,S-100-24V SKX-5D, 电子计数器 SKX-5D, 电子计数器 S-100-18V ,开关电源 电子计数器,SKX-4D 电子计数器,SKX-3D S-100-15V 开关电源 电子计数器,SKX-2D S-100-12V ,开关电源