布鲁克 timsTOF™ Pro 捕集离子淌度质谱

立即询价 进入厂商展台

微信客服

企业档案

企业类型:生产商

公司地址:中国北京市海淀区中关村南大街

主营产品:基质辅助激光解析电离飞行时间质谱仪(MALDI-TOF)、基质辅助激光解析电离串联飞行时间质谱仪(MALDI-TOF/TOF)、电喷雾离子阱质谱仪(ESI-Ion

展开更多

产品简介

布鲁克 timsTOF™ Pro 捕集离子淌度质谱the timsTOF™ Pro Mass Spectrometer Enables the Revolutionary PASEF Method for Next-Generation Proteomics Unique Trapped Ion Mobility Spectromet

详细内容

详细内容

公司简介

布鲁克 timsTOF™ Pro 捕集离子淌度质谱产品简介
the timsTOF™ Pro Mass Spectrometer Enables the Revolutionary PASEF Method for Next-Generation Proteomics
Unique Trapped Ion Mobility Spectrometry (TIMS) Adds New Dimension for Robust, Faster Proteome Analysis with Higher Sensitivity
Overview

Powered by PASEF
Mass spectrometry (MS)-based proteomics has become a powerful technology for the identification and quantification of thousands of proteins. However, the coverage of complete proteomes is still very challenging due to the limited speed, sensitivity and resolution of current mass spectrometers. 
The timsTOF Pro uses the Parallel Accumulation Serial Fragmentation (PASEF) acquisition method to provide extremely high speed and sensitivity to reach new depths in shotgun proteomics and phosphoproteomics using low sample amounts.

Achieve near 100% duty cycle for shotgun proteomics
A near 100% duty cycle for high sensitivity, high speed shotgun proteomics can now be achieved with the dual TIMS technology. The novel design allows for ions to be accumulated in the front section, while ions in the rear section are simultaneously released depending on their ion mobility. This process is called Parallel Accumulation Serial Fragmentation or PASEF.
PASEF digs deeper into the proteome
The timsTOF Pro powered by PASEF offers sequencing speed > 100 Hz without losing sensitivity by synchronizing the quadrupole isolation mass window with the elution time of the specific peptide packages from the TIMS funnel.
MaxQuant/Perseus and PEAKS Studio enabled data processing
An open-file data format allows researchers to directly work with the raw data and use industry leading software. MaxQuant has been adapted to manage 4D features in the space spanned by retention time, ion mobility, mass, and signal intensity which benefit the identification and quantification of peptides, proteins, and posttranslational modifications. PEAKS Studio combines de novo sequencing with tradtional databbase searches and is optimized for processing timsTOF raw data.
 
Technical Details
Outstanding hardware performance
 
The second generation dual TIMS analyzer is optimized for shotgun proteomics needs. Due to its unique geometry ions are released dependent on their mobility from the second section of the TIMS analyzer while the further incoming ions can be accumulated in parallel in the first part of the TIMS analyzer. With the parallel accumulation technology a duty cycle up to 100% can be achieved resulting in no ion loss.
In the timsTOF Pro an advanced segmented quadrupole mass filter is used for high ion transmission and isolation efficiency. The quadrupole mass position is synchronized with the elution times of the specific ions from the TIMS analyzer. Due to its ultra-high mass position switching time (< 1 ms) it enables the best performance for the PASEF method.
csm_Optimized-for-shotgun-proteomics_version2_d6e13753d4.jpg
TIMS
 
Trapped Ion Mobility Spectrometry (TIMS) is first and foremost a separation technique in gas phase, which resolves sample complexity with an added dimension of separation in addition to HPLC and mass spectrometry, increasing peak capacity and confidence in compound characterization.
PASEF
 
With speed in mind, Bruker experts redesigned MS/MS technology to meet the requirements of shotgun proteomics. Peptide ions are separated using trapped ion mobility spectrometry, eluted (~ 100 ms) and detected in the QTOF, generating the TIMS MS heat map (A). In the PASEF method (B) the same TIMS separation is used with the quadrupole isolating a certain ion species during its elution and immediately shifting to the next precursor. Parent and fragment spectra are aligned by mobility values. With the Parallel Accumulation Serial Fragmentation (PASEF) Technology >100 Hz sequencing speed can be achieved. With the PASEF method the MS/MS spectra quality of the low abundant peptides can be increased by selecting them several times.
 
布鲁克 timsTOF™ Pro 捕集离子淌度质谱产品相册



关键词:布鲁克  timsTOF™    Pro  捕集离子淌度质谱  布鲁克微生物质谱  

公司同类产品

  • 电喷雾飞行时间串联质谱

    电喷雾飞行时间串联质谱
    maXis II电喷雾飞行时间串联质谱高分辨 LC-QTOF 的市场引领者
      maXis II 在广泛的应用领域展现出前所未有的性能和解决最具挑战性分析难题的能力,这预示着maXis II 正
    更多详细

  • MALDI Biotyper微生物快速鉴定系统

    MALDI Biotyper微生物快速鉴定系统
    MALDI Biotyper微生物快速鉴定系统利用MALDI-TOF(基质辅助激光解吸电离飞行时间)质谱测定微生物独特的分子指纹谱来鉴定微生物。具体来说,MALDI Biotyper 检测的是存在于所 更多详细