联系我们
联系人:刘经理
产品展示
Human Deoxyribonuclease I (DNASE1) ELISA Kit进口
点击次数:160
价格:¥电议
更新日期:2026/8/24 23:51:04
生 产 地:中国大陆
产品型号:
商家名片
刘**
联系我时,请说明是阿仪网看到的,谢谢!
- 电话: 40*************************同步)
- 手机: 13******491
- 微信:
- 交换名片后展示联系方式 → →
相关标签:Human,Deoxyribonuclease,I,(DNASE1),ELISA,Kit进口
详细内容
Cat No.eia05573h
Human Deoxyribonuclease I (DNASE1) ELISA Kit
Dear customers, thank you for choosing our products. This product is suitable for in vitro qualitative detection of human serum, plasma or cell culture supernatant and organizations in the natural and recombinant DNASE1 concentration. Detection of other special sample please contact our technical support. The kit is for research use only. Please read the instructions carefully before using and check the kit components. If you have any questions, please contact SANCHEZ INC You will get our full range of services.
This kit employs Double Antibody Sandwich Technique. The principle of Double Antibody Sandwich is based on characteristics of the tested antigen with more than two valances which can identify coated antibody and detection antibody at same time. The specific process is as follows:
1. Connect the specific antibodies and solid phase carriers to form immobilized antibodies. Wash out uncombined antibodies and impurities. Seal the rest binding sites with irrelevant proteins.
2. Join under test with immobilized antibodies for contact reaction. After a while, combine antigens in and antibodies on carriers into the antigens complex. Wash out uncombined antibodies and impurities.
3. Add biotin labeling antibodies to combine with the antigens on immune complexes. Wash out the uncombined biotin labeling antibodies thoroughly. The enzyme amount on the carrier is now positively related to the amount of the tested substance in specimens.
4. Add horseradish peroxidase to label the avidins and incorporate them with the biotin labeling antibodies. Wash out the incorporated enzyme markers thoroughly. The enzyme amount on the carrier is now positively related to the amount of the tested substance in specimens.
Note: an antibody molecule can be marked on several biotin molecules and a biotin molecule can be connected with a HRP-Avidin to form numbers of horseradish peroxidases combining with antibodies which shows higher sensitivity and amplification effect comparing with traditional direct HRP-Antibodies.
【Detection principle of Human Deoxyribonuclease I (DNASE1) ELISA kit】
This experiment use double-sandwich elisa technique and the ELISA Kit provided is typical. The pre-coated antibody is human DNASE1 monoclonal antibody and the detecting antibody is polyclonal antibody with biotin labeled. Samples and biotin labeling antibody are added into ELISA plate wells and washed out with PBS or TBS. Then Avidin-peroxidase conjugates are added to ELISA wells in order; Use TMB substrate for coloring after reactant thoroughly washed out by PBS or TBS. TMB turns into blue in peroxidase catalytic and finally turns into yellow under the action of acid. The color depth and the testing factors in samples are positively correlated.
【Kit composition】
name 96 Tests 48 TestsStorage
1.antibody precoated plate 8×12 8×64/-20℃
2.Human DNASE1 Standards 2 vial 1 vial4/-20℃
3.Biotinylated antibody(1:100) 1 vial 1 vial4/-20℃
4.Enzyme conjugate(1:100) 1vial 1 vial4/-20℃
5.Enzyme diluent 1vial 1vial 4/-20℃
6.antibody diluent 1vial 1 vial4/-20℃
7.Standard diluent 1vial 1 vial 4/-20℃
8.Sample diluent 1vial 1 vial 4/-20℃
9.Washing buffer (1:25) 1 vial 1 vial 4/-20℃
10.Colour Reagent A 1 vial 1 vial 4/-20℃
11.Colour Reagent B1 vial 1 vial 4/-20℃
12.Colour Reagent C 1 vial 1 vial 4/-20℃
13.Instruction 1 set 1 set RT
Note:
RT:Room temperature
Standard:Frozen dried
Colour Reagent A: Avoid light
【Necessary for testing their own test facilities and equipment】
1. Microplate reader (450nm detection wavelength filter, 570nm or 630nm correction wavelength filters).
2. Washer (adjustable amount of liquid injection to ensure that each well 350μl lotion without overflow).
3. Clean benches, biological safety cabinets, fume hoods.
4. High-precision single-channel dispenser (range 0.5-10μl-20μl, 20-200μl, 200-1000μl).
5. High-precision multi-channel plus liquid (8 or 12, the range of 50-300μl of).
6. 37℃ incubator.
7. Low temperature centrifuge.
8. Refrigerators (4℃, -20℃, -86℃).
9. Analytical balance.
10. Scissors, tweezers, pliers, and so on.
11. Swirl mixing device, low-frequency oscillator, and so on.
【Necessary for testing their own testing supplies and reagents】
1. Centrifuge tube (capacity of 1.5ml, 5ml, and so on).
2. Disposable tip (range of 0.5-10μl-20μl, 20-200μl, 200-1000μl).
3. Pure water or distilled water.
4. Coordinate paper.
5. Absorbent paper.
6. EDTA, sodium citrate, heparin
【Sample collection Note】
3. The samples should appear clear and transparent. And all the suspension should be removed through centrifugation.
4. If collected samples are not timely detected, they should be divided according to single usage amount and frozen reserved in refrigerator at -20-80℃, avoiding the repeated freeze-thaw.
5. According to the actual situation of the samples, make proper multiple dilutions (Pre-experiment is strongly recommended in order to confirm the dilution ratio)
Human,Deoxyribonuclease,I,(DNASE1),ELISA,Kit进口