联系我们
联系人:麻小姐
产品展示
福禄克i2500-18 iFlex™Flexible CurrentProbes
点击次数:575
价格:¥电议
更新日期:2026/6/30 18:56:31
生 产 地:中国大陆
产品型号:
- 电话: 07********618
- 手机: 15******071
- 微信:
- 交换名片后展示联系方式 → →
详细内容
i2500-18 iFlex™ Flexible Current Probes
Unprecedented measurement flexibility
The iFlex flexible current probe (included) expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access. Overview
Be ready for anything.
The Fluke iFlex flexible current probes expand the measurement range of the select Fluke meters to 2500 A ac while providing the ultimate measurement flexibility. The iFlex probes connect directly to the meter, displaying current measurements without error prone scaling factors. The 1.8 m (6 ft) cord allows separation between the measurement location and the clamp meter making it easier to view the display. The large loop size and thin cross section allow measurement of awkward sized conductors and improved wire access in crowded spaces. Available in 25 cm (10 in) and 45 cm (18 in) sizes.
Safety Conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV

Features and benefits


- Expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access
- CAT IV 600 V, CAT III 1000 V
- 7.5 mm coil diameter allows measurement in tight spaces
- Ergonomic design allows easy operation with one hand
- 1.8 m (6 ft) cable
- Three-year warranty
- How-to open the i2500-18 and i2500-10 iFlex flexible current probes:
-
Twist to unlock Pull to open 

- Safety Conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV
*When used with compatible Fluke meter. Accuracy stated includes probe and meter accuracy.Specifications
i2500-18 and i2500-10
Range
Resolution
Accuracy
AC Current*
2500 A
0.1 A
3% ± 5 digits**
Frequency*
500 Hz
0.1 Hz
0.5% ± 5 digits
External magnetic
field rejection
(with cable >10 cm from the coupling)40 dB
Inrush*
•
Safety rating
CAT III 1000 V, CAT IV 600 V
** For position accuracy at non-optimum positions, see Position sensitivity specifications table “A
.gif)
Position sensitivity specifications
Distance from optimum
i2500-10
i2500-18
Additional iFlex error
A
0.5 in (12.7 mm)
1.4 in (35.6 mm)
± 0.5%
B
0.8 in (20.3 mm)
2.0 in (50.8 mm)
± 1.0%
C
1.4 in (35.6 mm)
2.5 in (63.5 mm)
± 2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature.
-
型号名称 描述 i2500-18 i2500-18 iFlex™ Flexible Current Probes 