简单介绍:Gas sorption isotherms
Gas sorption analyzer
Gas sorption apparatus
Gas sorption analyser
Gas adsorption analyzer
Gas adsorption analysis
Gas sorption surface analysis
High speed gas sorption

商家名片
陈**
联系我时,请说明是阿仪网看到的,谢谢!
  • 电话: 13*******************138
  • 手机: 15******297
  • 微信:
  • 交换名片后展示联系方式 → →
相关标签:Gas,sorption,isotherm,Gas,adsorption,isotherm,Gas,adsorption,isotherm,types

详细内容

V-Sorb 4800P specific surface area and pore size analyzer Introduction

V-Sorb 4800P researched from Gold APP Instruments experts for surface area and pore size determination with using of static volumetric principle. Multi pioneered techs heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level among world technology. It designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers’ real demands. The high cost performance of V-Sorb 4800P easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ requests.

V-Sorb 4800P specific surface area and pore size analyzer parameters

Analysis Method: static volumetric nitrogen adsorption

Versatility: Adsorption and desorption isotherms, Single and multi-point BET surface area analysis, T-plot external surface area, True density analysis, BJH pore size, BJH total pore volume and porosity, T-plot micropore analysis, MP micropore, Langmuir surface area, Horvath-Kawazoe (HK) micropore, Saito-Foley (SF) micropore, Dubinin-Astakhov (DA) micropore, Dubinin-Radushkevich (DR) micropore, carbon black (STSA) etc.

Measuring Ranges: 0.01m2/g to no known upper limit (surface area); 0.35 to 500nm (pore size)

Accuracy: repeatability errors ≤1%

Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life

Coolant Level Prober: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change

Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument’s stability

Sample Ports: four samples’ analyzing and four samples’ degassing concurrently

Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)

Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)

Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998

Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)

Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pump’s start/stop

Sample Types: powders, particle, fiber, flakes and other materials

Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO2, CO, C4H10 etc. non-corrosive gases are optional

Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability

Data Reduction: Windows®-based independent developed Gold APP softwareTM, perfect versatility, produced full featured and multi-model reports

Specifications: Height 22.05 inches (56cm)* Width 20.87 inches (53cm)*Depth 23.62 inches (60cm); 132 pound (60kg)

V-Sorb 4800P specific surface area and pore size analyzer features

A: Vacuum System

1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.

2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.

3. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).

B: Control System

1. Industry used programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.

2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.

C. Measures for Improving Accuracy

1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).

2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).

3. Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.

4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change.

5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s macro-change.

D. Data Acquisition and Reduction

1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzer’s applications extension and interconnection, can also conveniently switched to RS232 and USB modes.

2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.

V-Sorb 4800P specific surface area and pore size analyzer application

1. Super micro powder, nanomaterials, particle and fiber shaped specific surface area analysis.

2. Product quality control for powder materials related corporations.

3. Research institutes, universities for BET theory teaching.

4. Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.

5. Other researches concern surface area performance.

Contact info:

Web: www.jinaipu.com/ www.app-one.com.cn

Email: sales@jinaipu.com

Tel.: 0086-10-82133318 Ext.810

Fax: 0086-10-82118197

Mobile: 0086-

IMs:

Skype: Gold-APP-Instruments

Yahoo: goldappinstruments@ymail.com

Gtalk: goldappinstruments2008@gmail.com

Gas,sorption,isotherm,Gas,adsorption,isotherm,Gas,adsorption,isotherm,types

采购记录

优质供应

相关文章

  • 友情链接
  • 热词推荐
在线咨询5分钟应答

提交