氯气CL2气体检测模块
电化学气体变送模块是一款专门为OEM客户设计制作的产品,这款模块采用进口电化学气体传感器,经过标定调较之后,可以用于测量几十种气体,包括诸如:O2、CO、H2S、CL2、SO2、O3等,满足了用户对低成本、嵌入式的OEM设计要求,极大的方便了用户的使用。
模块特点:
1:断电后可以自动短接参考极和工作极,保护传感器的寿命。2:傻瓜式两线制接线方式,接线人员不用考虑电源的正负,接反了也能正常工作。3:模块性能稳定可靠,具有过压和过流保护。
CL2模块氯气传感器模块
CL2模块氯气传感器模块技术参数
传 感 器:电化学测量范围:0~10 ppm、20 ppm、200ppm分 辨 率:0.001ppm(0~10 ppm);0.01ppm(0~20 ppm);0.1ppm(0~200 ppm)响应时间:≤30秒 工作模式:连续工作工作电压:DC12~36V(一般是按照DC24V来设置)输出电流:4-20mA(也可直接输出继电器开关量) 输出方式:4~20mA ,40~200mV,RS485温度范围:-20℃ ~ 50℃ 湿度范围:0 ~ 95%(RH)无冷凝 外形尺寸: 44×44mm
CL2模块氯气传感器模块特点:1:断电后可以自动短接参考极和工作极,保护传感器的寿命。2:傻瓜式两线制接线方式,接线人员不用考虑电源的正负,接反了也能正常工作。3:模块性能稳定可靠,具有过压和过流保护。
Cl2气体检测管 109SA CHLORINE 1-40ppm
Tube No.109SA 1. PERFORMANCE1) Measuring range :1-40 ppmNumber of pump strokes 1(100ml)2) Sampling time :2 minutes/1 pump stroke3) Detectable limit :0.3 ppm4) Shelf life :2 years5) Operating temperature :0~40℃6) Reading :Direct reading from the scale calibrated by 1 pump stroke7) Colour change :White→Yellowish orange2. RELATIVE STANDARD DEVIATIONRSD-low:10% RSD-mid.:5% RSD-high:5%3. CHEMICAL REACTION0-Toluidine is oxidized and Orthoquinone is produced.4. CALIBRATION OF THE TUBEPERMEATION TUBE METHOD5. INTERFERENCE AND CROSS SENSITIVITYGAS To pump13510152025303540100mlppm?? ?? ??????????????109SA CHLORINESubstance ppm Interference ppm CoexistenceBromine 0.1 Similar stain is produced. 1 Higher readings are given.Chlorine dioxide 0.3 〃1 〃Chlorine The top of discoloured layer be-Nitrogen dioxide Pale yellow stain is produced. conc.×1/2 comes unclear higher readingsare given.
量程:0-20ppm
采用电化学气体传感器;
供电12-36VDC
4-20mA两线电流信号输出
带温度补偿
检测分辨率可到0.01ppm
注:外壳为压铸铝防爆外壳,带气室
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
1,1-二氯乙烷CH3CHCl2气体检测管1,1-Dichloroethane 235SA 1,1- 10-160ppm
Tube No.235SA1. PERFORMANCE1) Measuring range :10-160 ppmNumber of pump strokes 1(100mr)2) Sampling time :2 minutes/1 pump stroke3) Detectable limit :3 ppm4) Shelf life :1 year(Necessary to store in a refrigerated place ; 0~10℃)5) Operating temperature :0~40℃6) Operating Humidity :20-90 R.H.%7) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")8) Reading :Direct reading from the scale calibrated by 1 pump stroke9) Colour change :White→Purple2. RELATIVE STANDARD DEVIATIONRSD-low:15% RSD-mid.:15% RSD-high:10%3. CHEMICAL REACTIONChlorine is produced by decomposing with an Oxidizer.By reacting between this Chlorine and 3, 3’-Dimethylnaphthidine,Nitroso-compound is produced.CH3CHCI2+CrO3+H2SO4→CI2CI2+3, 3’-Dimethylnaphthidine→Nitroso-compound4. CALIBRATION OF THE TUBEGAS CHROMATOGRAPHY5. INTERFERENCE AND CROSS SENSITIVITY????GAS ???? To pumpDETECTOR TUBE(Olive)PRETREAT TUBE1601401201008060402010ppm100ml235S 1,1-DICHLOROETHANESubstance Interference ppm CoexistenceNitrogen oxides Similar stain is produced. Higher readings are given.Halogens 〃〃Halogenated hydrocarbons 〃〃Alcohols Tafhfeec atecdc.uracy of readings is not 400 Lower readings are given.Hexane FIG.1 〃20 〃Toluene FIG.2 〃20 〃0100200Hexane〔ppm〕?FIG.1 Influence of Hexane1,1-Dichloroethane indicating value 〔ppm〕50 100 0100200Toluene〔ppm〕?FIG.2 Influence of Toluene
二氯甲烷CH2Cl2气体检测管180S Dichloromethane 10-1000ppm
Tube No.180S1. PERFORMANCE1) Measuring range :30-1,000 ppm 10-200 ppmNumber of pump strokes 2(200ml) 4(400ml)2) Sampling time :1.5 minutes/1 pump stroke3) Detectable limit :5 ppm(400ml)4) Shelf life :2 years(Necessary to store in a refrigerated place ; 0~10℃)5) Operating temperature :5~40℃6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")7) Reading :Direct reading from the scale calibrated by 2 pump strokes8) Colour change :White→Reddish orange2. RELATIVE STANDARD DEVIATIONRSD-low:15% RSD-mid.:15% RSD-high:15%3. CHEMICAL REACTIONChlorine is produced an Oxidizer. By reacting between this Chlorine and o-Toluidine, Orthoquinone is produced.CH3OCI3+CrO3+H2SO4→CI24. CALIBRATION OF THE TUBEGAS CHROMATOGRAPHY5. INTERFERENCE AND CROSS SENSITIVITY????GAS To pumpDETECTOR TUBE(Olive)PRETREAT TUBE100080050040020010030ppm200ml180S DICHLOROMETHANESubstance Interference CoexistenceHalogens or Halogenated hydrocarbons Similar stain is produced. Higher readings are given.FIG.1(NOTE)When the concentration is below 200 ppm, 4 pump strokes can be used to determine the lower concentrationFollowing formula is available for the actual concentration.Actual concentration=1/3×Temperature corrected value.02004006008001000Chlorine〔ppm〕?FIG.1 Influence of Chlorine
二氯苯C6H4Cl2气体检测管 215S p-DICHLOROBENZENE 10-150ppm
1. PERFORMANCE1) Measuring range :10-150 ppmNumber of pump strokes 1(100ml)2) Sampling time :1.5 minutes/1 pump stroke3) Detectable limit :6 ppm4) Shelf life :1 year (Necessary to store in a refrigerated place ; 0~10℃)5) Operating temperature :0~40℃6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")7) Reading :Direct reading from the scale calibrated by 1 pump stroke8) Colour change :White→Blueish purple2. RELATIVE STANDARD DEVIATIONRSD-low:15% RSD-mid.:10% RSD-high:10%3. CHEMICAL REACTIONBy reacting with an Oxidizer, Hydrogen chloride is prodaced and PH indicator is discoloured.C6H4CI2+PbO2+H2SO4→HCI4. CALIBRATION OF THE TUBEGAS CHROMATOGRAPHY5. INTERFERENCE AND CROSS SENSITIVITYGAS To pump1501201008060402010ppm200ml????Tube No.215S p-DICHLOROBENZENE95Substance Interference CoexistenceBenzene Similar stains are produced and higherreadings are given.Toluene 〃Blueish green stains are produced andHexane the top of discoloured layer becomes 〃unclear.Ethanol The accuracy of reading is not affected. The accuracy of reading is not affected.TEMPERATURE CORRECTION TABLETube Corrected Concentration (ppm)Readings 10℃ 15℃ 20℃ 25℃ 30℃ 35℃ 40℃(ppm) (50°F) (59°F) (68°F) (77°F) (86°F) (95°F) (104°F)150 - - 150 108 66 48 30100 - - 100 72 46 37 2650 110 80 50 28 26 21 1620 50 27 20 14 10 8 610 22 15 10 8 6 5 4
系列产品荣获新产品证书
仪器名称 | 型号 | 被测气体 | 测量范围 | 最大量程 | 误差 | 响应时间 | 传感器寿命 |
CO气体检测报警仪 | XR-01 | CO | 0-1000PPm | 2000PPm | ≤±5% | ≤35秒 | 2~4年 |
H2S气体检测报警仪 | XR-04 | H2S | 0-200PPm | 1000PPm | ≤±8% | ≤40秒 | 2~3年 |
H2气体检测报警仪 | XR-05 | H2 | 0-1000PPm | 2000PPm | ≤±5% | ≤40秒 | 2~3年 |
CL2气体检测报警仪 | XR-06 | CL2 | 0-20PPm | 250PPm | ≤±5% | ≤60秒 | 2~3年 |
NH2气体检测报警仪 | XR-07 | NH2 | 0-50PPm | 200PPm | ≤±5% | ≤100秒 | 2~3年 |
SO2气体检测报警仪 | XR-O8 | SO2 | 0-100PPm | 500PPm | ≤±5% | ≤25秒 | 2~3年 |
NO气体检测报警仪 | XR-09 | NO | 0-1000PPm | 5000PPm | ≤±5% | ≤35秒 | 2~4年 |
NO2气体检测报警仪 | XR-10 | NO2 | 0-200PPm | 1000PPm | ≤±5% | ≤60秒 | 2~3年 |
甲醛气体检测报警仪 | XR-11 | 甲醛 | 0-20PPm | 500PPm | ≤±5% | ≤140秒 | 2~3年 |